Tancia Pires

Tancia Pires

Auto-generated profile, based on publicly available information

Tancia Pires

Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2024 in Radiography
Verified
Journal Article
Open access
PRPriyanka
Priyanka
RKRajagopal Kadavigere
Rajagopal Kadavigere
SNShailesh S Nayak
Shailesh S Nayak
Obhuli Chandran MadhivananObhuli Chandran Madhivanan
Obhuli Chandran Madhivanan
ASA. Shirlal
A. Shirlal
SPSaikiran Pendem
Saikiran Pendem
Magnetic Resonance Imaging (MRI) has revolutionized the diagnosis and treatment of musculoskeletal disorders. Parallel imaging (PI) and compressed sensing (CS) techniques reduce scan time, but higher acceleration factors decrease image quality. Artificial intelligence has enhanced MRI reconstructions by integrating deep learning algorithms. Therefore, the study aims to review the impact of Artificial intelligence-assisted compressed sensing (AI-CS) and acceleration factors on scan time and image quality in musculoskeletal MRI. Database searches were completed across PubMed, Scopus, CINAHL, Web of Science, Cochrane Library, and Embase to identify relevant articles focusing on the application of AI-CS in musculoskeletal MRI between 2022 and 2024. We utilized the Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines to extract data from the selected studies. Nine articles were included for the final review, with a total sample size of 730 participants. Of these, seven articles were rated as high, while two articles were considered to be of moderate quality. MRI examination with AI-CS showed scan time reduction of 18.9-38.8% for lumbar spine, 38-40% for shoulder, 54-75% for knee and 53-63% for ankle. AI-CS showed a significant reduction in scan time and improved image quality for 2D and 3D sequences in musculoskeletal MRI compared with PI and CS. Determining the optimal acceleration factor necessary to achieve images with higher image quality compared to traditional PI techniques is required before clinical implementation. Higher acceleration factors currently lead to reduced image scores, although advancements in AI-CS are expected to address the limitation. AI-CS in MRI improves patient care by shortening scan times, reducing patient discomfort and anxiety, and produces high quality images for accurate diagnosis.

9 January 2025 in F1000Research
Verified
Journal Article
Open access
PDF file
RSRiyan Mohamed Sajer
Riyan Mohamed Sajer
SPSaikiran Pendem
Saikiran Pendem
RKRajagopal Kadavigere
Rajagopal Kadavigere
D.Dr. Priyanka .
Dr. Priyanka .
SNShailesh S Nayak
Shailesh S Nayak
VRVarsha Raghu
Varsha Raghu
Introduction Magnetic resonance imaging (MRI) is essential for brain imaging, but conventional methods rely on qualitative contrast, are time-intensive, and prone to variability. Magnetic resonance finger printing (MRF) addresses these limitations by enabling fast, simultaneous mapping of multiple tissue properties like T1, T2. Using dynamic acquisition parameters and a precomputed signal dictionary, MRF provides robust, qualitative maps, improving diagnostic precision and expanding clinical and research applications in brain imaging. Methods Database searches were performed through PubMed, Embase, Scopus, Web of science to identify relevant articles focusing on the application of MR finger printing in the adult brain. We utilized the preferred reporting items for systematic reviews and meta-analysis guidelines to extract data from the selected studies. Results Nine articles were included in the final review, with a total sample size of 332 participants. In healthy brains, notable regional, sex, age, and hemispheric variations were identified, particularly in the corpus callosum and thalamus. MRF effectively differentiated meningioma subtypes, glioma grades, and IDH mutation status, with T2 values providing particularly predictive for glioma classification. In brain metastases, significant relaxometry differences were noted between normal and lesional tissues. For multiple sclerosis, MRF values correlated with clinical and disability measures, distinguishing relapsing-remitting secondary progressive forms. In traumatic brain injury, longitudinal T1 changes strongly correlated with clinical recovery, surpassing T2 values. Conclusions The systematic review highlighted MRD as a groundbreaking technique that enhances neurological diagnosis by simultaneously quantifying T1 and T2 relaxation times. With reduced acquisition times, MRF outperforms conventional MRI in detecting subtle pathologies, distinguishing properties, and providing reliable biomarkers.

13 June 2023 in Journal of Health and Allied Sciences NU
Verified
Journal Article
Open access
PDF file
TPTancia Pires
Tancia Pires
JMJaseemudheen MM
Jaseemudheen MM
Since the discovery of magnetic resonance imaging (MRI) as an imaging modality, it has evolved immensely and is still doing so. Most imaging modalities have made bedside or emergency imaging possible due to their portability. This aspect is yet to be fully evaluated and established in the case of MRI as its high-field strength requires specialized infrastructure and its time-consuming nature makes its portability questionable. The goal of this review is to access the efficiency and feasibility of low-field portable MRI (pMRI) systems in a wide array of health care applications. Articles from indexed journals, on PubMed, Springer, Elsevier, etc. databases, relevant to this study were searched and reviewed. This review provides an atypical design that could be used in making a pMRI unit that could find its potential in diagnosing a wide variety of pathologies with an added advantage of imaging critical patients in the intensive care unit or patients in isolation due to its portability, imaging patients with implants or prosthesis effectively due to its low field, pediatric imaging due to its high speed, for guided interventions, imaging obese and claustrophobic patients due to its open nature, in dental imaging, extremity scanning, etc. With its vast spectrum of applications in the health care system, the future of low-field pMRI units seems to be bright.

8 January 2025 in F1000Research
Verified
Journal Article
Open access
PDF file
MNMaria Nicolet
Maria Nicolet
D.Dr. Priyanka .
Dr. Priyanka .
RKRajagopal Kadavigere
Rajagopal Kadavigere
SNShailesh S Nayak
Shailesh S Nayak
SPSaikiran Pendem
Saikiran Pendem
VRVarsha R
Varsha R
Background Cervical spondylosis is the common degenerative disease of the vertebrae in adults which can lead to change in sagittal alignment of cervical spine. Radiograph and Magnetic resonance imaging (MRI) are widely used imaging modalities for measuring the sagittal parameters. However sagittal parameters measured using radiograph and MRI can be influence by patient positioning and imaging technique. The study aims to compare sagittal parameters measured using MRI (Magnetic Resonance Imaging) and radiograph in cervical spondylosis patients. Methods The study was done retrospectively. 77 patients who underwent both MRI and radiograph were included in the study. The sagittal parameters such as Neck Tilt (NT), T1 slope (T1S), thoracic inlet angle (TIA), C2-C7 angle (C2-C7A) and C2-C7 sagittal vertical axis (C2-C7 SVA) were measured on sagittal MRI and lateral cervical spine radiograph. Paired t-test was used to compare cervical sagittal measurements between MRI and radiography. Results The cervical sagittal parameters such as NT, T1S, TIA and C2-7 SVA showed significant difference between MRI and radiograph (p < 0.05). But C2-C7A did not show significant difference (p > 0.05) Conclusion The study concludes that MRI cannot be used as an alternative to cervical spine radiograph in spondylosis patient for measuring the sagittal balance as there was significant difference between sagittal parameters except C2-C7 A.

4 December 2024 in Diagnosis
Verified
Journal Article
Closed access
TPTancia Pires
Tancia Pires
SPSaikiran Pendem
Saikiran Pendem
JMJaseemudheen MM
Jaseemudheen MM
D.Dr. Priyanka .
Dr. Priyanka .
Introduction: Synthetic magnetic resonance imaging (SyMRI) is a non-invasive, robust MRI technique that generates multiple contrast-weighted images by acquiring a single MRI sequence within a few minutes, along with quantitative maps, automatic brain segmentation, and volumetry. Since its inception, it has undergone technical advancements and has also been tested for feasibility in various organs and pathological conditions. This scoping review comprehensively pinpoints the critical technical aspects and maps the wide range of clinical applications/benefits of SyMRI. Content: A comprehensive search was conducted across five databases, PubMed, Scopus, Web of Science, Embase, and CINAHL Ultimate, using appropriate keywords related to SyMRI. A total of 99 studies were included after a 2-step screening process. Data related to the technical factors and clinical application was charted. Summary: SyMRI provides quantitative maps and segmentation techniques comparable to conventional MRI and has demonstrated feasibility and applications across neuroimaging, musculoskeletal, abdominal and breast pathologies spanning the entire human lifespan, from prenatal development to advanced age. Certain drawbacks related to image quality have been encountered that can be overcome with technical advances, especially AI-based algorithms. Outlook: SyMRI has immense potential for being incorporated into routine imaging for various pathologies due to its added advantage of providing quantitative measurements for more robust diagnostic and prognostic work-up with faster acquisitions and greater post-processing options.

1 January 2025 in International Journal of Biomedical Imaging
Verified
Journal Article
Open access
ASAbhijith S.
Abhijith S.
RKRajagopal Kadavigere
Rajagopal Kadavigere
PSPriya Pattath Sankaran
Priya Pattath Sankaran
DSDharmesh Singh
Dharmesh Singh
D.Dr. Priyanka .
Dr. Priyanka .
SPSaikiran Pendem
Saikiran Pendem
Background: Intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is a noncontrast technique estimating diffusion and perfusion parameters via multiple b ‐values, essential for oncology imaging. However, there is limited collective evidence regarding the efficacy of IVIM in oncology imaging compared to contrast‐enhanced (CE) MRI perfusion techniques. This systematic review and meta‐analysis compared IVIM′s diagnostic accuracy and correlation with CE MRI perfusion techniques. Methods: Following PRISMA guidelines (PROSPERO‐registered), a literature search across five databases (PubMed, Scopus, Embase, Web of Science, and Cochrane Library) was conducted. Diagnostic metrics, including AUC, sensitivity, specificity, and correlation coefficients, were analyzed using a random‐effects model, with heterogeneity and publication bias assessed via I 2 statistics and Egger′s test. Results: Eighteen studies on breast, rectal, and brain cancers were analyzed. For breast cancer, IVIM showed 83.50% sensitivity and 81.24% specificity compared to dynamic contrast‐enhanced (DCE) MRI′s 88.04% sensitivity and 65.98% specificity. In rectal cancer, IVIM achieved 70.9% sensitivity and 56.2% specificity, outperforming DCE MRI′s 58.11% sensitivity and 72.49% specificity. For gliomas, IVIM demonstrated 92.27% sensitivity and 74.06% specificity compared to dynamic susceptibility contrast (DSC) MRI′s 95.71% sensitivity and 92.91% specificity. Correlations between IVIM and CE parameters were weak to moderate. Conclusion: IVIM demonstrated equal or superior diagnostic performance to CE MRI in breast cancer, rectal cancer, and gliomas, offering a noncontrast alternative. However, unclear parameter correlations warrant future studies focusing on IVIM protocol optimization based on perfusion regimes.