Submarine Resources Research Program (SRRP), Institute for Earth and Material Sciences (EMS), Japan Agency for Marine-Earth Science and Technology (JAMSTEC) Yokosuka, Japan
Auto-generated profile, based on publicly available information
Takafumi Kasaya
Submarine Resources Research Program (SRRP), Institute for Earth and Material Sciences (EMS), Japan Agency for Marine-Earth Science and Technology (JAMSTEC) Yokosuka, Japan
We conducted a self-potential survey at an active hydrothermal field, the Izena hole in the mid-Okinawa Trough, southern Japan. This field is known to contain Kuroko-type massive sulphide deposits. This survey measured the self-potential continuously in ambient seawater using a deep-tow array, which comprises an electrode array with a 30-m-long elastic rod and a stand-alone data acquisition unit. We observed negative self-potential signals not only above active hydrothermal vents and visible sulphide mounds but also above the flat seafloor without such structures. Some signals were detectable >50 m above the seafloor. Analysis of the acquired data revealed these signals’ source as below the seafloor, which suggests that the self-potential method can detect hydrothermal ore deposits effectively. The self-potential survey, an easily performed method for initial surveys, can identify individual sulphide deposits from a vast hydrothermal area.
Although seafloor massive sulfide (SMS) deposits are crucially important metal resources that contain high‐grade metals such as copper, lead, and zinc, their internal structures and generation mechanisms remain unclear. This study obtained detailed near‐seafloor images of electrical resistivity in a hydrothermal field off Okinawa, southwestern Japan, using deep‐towed marine electrical resistivity tomography. The image clarified a semi‐layered resistivity structure, interpreted as SMS deposits exposed on the seafloor, and another deep‐seated SMS layer at about 40‐m depth below the seafloor. The images reinforce our inference of a new mechanism of SMS evolution: Upwelling hydrothermal fluid is trapped under less‐permeable cap rock. The deeper embedded SMS accumulates there. Then hydrothermal fluids expelled on the seafloor form exposed SMS deposits.
We performed a simultaneous survey of self-potential and plume turbidity using an autonomous underwater vehicle (AUV) above the Sunrise deposit in the Myojin Knoll caldera of the Izu-Ogasawara arc. A 10-m-long electrode rod, on which five electrodes referenced with a common electrode were mounted, was connected at the tail of an AUV. The survey was conducted at a typical speed of 2 knots, covering the 1500 m × 1500 m area with a typical spacing of survey lines of 100 m. With AUV altitude of 100 m above the seafloor, a negative self-potential anomaly of a few millivolts was observed. The self-potential anomaly was found to spread 300 m × 300 m. The self-potential is probably attributable to the geo-battery mechanism: electric current is generated by redox reactions occurring around an ore body crossing a redox contrast. Assuming that the source of the self-potential is an electric current dipole, we can image a southward-dipping dipole with the moment of approximately 103 A m, approx. 30 m below the southern part of the ore deposit. Anomalies of turbidity, which are correlated to ambient temperature and which are signatures of discharged hydrothermal fluids, were distributed more broadly than the self-potential. Some turbidity anomalies were found without self-potential anomalies. They were probably transported by the ocean current. Spatial decoupling between the self-potential and turbidity anomalies suggests that the direct contribution of hydrothermal fluids to the self-potential anomalies is probably a secondary effect. The survey altitude of 100 m and the survey speed of 2 knots in the present study represent practical limitations for the self-potential survey when active hydrothermal fields are targeted. We have observed that the self-potential method responds exclusively to the presence of hydrothermal ore deposits. This behavior differs from other methods for exploring seafloor hydrothermal ore deposits: The geomagnetic method responds not only to ore deposits but also to volcanic bodies. The plume method can detect remote hydrothermal activities, but the source locations are not necessarily specified. The self-potential method is useful as an excellent exploration tool, particularly for initial surveys.
Exploration Geophysics is published by CSIRO PUBLISHING on behalf of the Australian Society of Exploration Geophysicists. Papers published report the results of significant case histories and relevant original research in geophysics, with emphasis on the Australian and similar environments.
Sagami Bay is an active tectonic area in Japan. In 1993, a real-time deep sea floor observatory was deployed at 1,175 m depth about 7 km off Hatsushima Island, Sagami Bay to monitor seismic activities and other geophysical phenomena. Video cameras monitored biological activities associated with tectonic activities. The observation system was renovated completely in 2000. An ocean bottom electromagnetic meter (OBEM), an ocean bottom differential pressure gauge (DPG) system, and an ocean bottom gravity meter (OBG) were installed January 2005; operations began in February of that year. An earthquake (M5.4) in April 2006, generated a submarine landslide that reached the Hatsushima Observatory, moving some sensors. The video camera took movies of mudflows; OBEM and other sensors detected distinctive changes occurring with the mudflow. Although the DPG and OBG were recovered in January 2008, the OBEM continues to obtain data.
31 March 2021 in Journal of Geophysical Research: Solid Earth
The Atotsugawa fault is one of the most active faults in Japan, and the strain accumulation at the fault is considered to be caused by an aseismic shear zone in the fluid‐rich lower crust. To identify the shear zone and investigate the origin of the aqueous fluid in the lower crust, we deployed a Network‐MT survey in addition to a conventional wideband‐MT survey around the fault and performed an inversion combining both the MT data sets. In the inversion, by modifying a conventional inversion algorism, we accurately represented kilometer‐scale dipoles of the Network‐MT measurement to provide constraints on the electrical resistivity structure. In the lower crust under the study area, there are localized conductive anomalies below the Atotsugawa fault, the Ushikubi fault, and the Takayama‐Oppara fault zone. Comparing our electrical resistivity structure with the seismic velocity structure, we interpreted that the lower‐crustal conductors are localized ductile shear zones with highly connected fluid. We considered that the localized ductile shear zones are responsible for the strain accumulation along the respective active faults. In addition, in the mantle wedge above the subducting Philippine Sea slab and its downward extension, a highly conductive portion is detected, which may be attributed to the fluid dehydrated from the Philippine Sea slab and/or the Pacific slab. The existence of the large conductive area supports the suggestion of previous seismic and geochemical studies that the fluid of the lower crust around the Atotsugawa fault originated from subducting slabs.