Alfons Dehé

Alfons Dehé

Auto-generated profile, based on publicly available information

Alfons Dehé

Hahn-Schickard-Gesellschaft für angewandte Forschung e.V., Villingen-Schwenningen

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2001 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
MBM Brauer
M Brauer
ADAlfons Dehe
Alfons Dehe
TBT Bever
T Bever
SBS Barzen
S Barzen
SSS Schmitt
S Schmitt
RAR Aigner
R Aigner

30 August 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SASebastian Anzinger
Sebastian Anzinger
CBChristian Bretthauer
Christian Bretthauer
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
ADAlfons Dehe
Alfons Dehe
In this work, novel airborne capacitive micromachined ultrasonic transducers (CMUTs) based on a dual-backplate (DBP) technology are presented. In contrast to conventional CMUTs, these transducers use a three-electrode-based capacitive system, where the membrane is placed between two highly-perforated counter electrodes, enabling enlarged displacement amplitudes in electrostatic actuation and wide and tunable bandwidth due to a ventilated air cavity. Fabricated DBP-CMUT prototypes therefore show exceptionally high receive and transmit sensitivities of -34.5 dB(V/Pa) and 259 nm/V, respectively, in their 84 kHz resonance. The viscous dissipation introduced by ventilating the cavity results in a wide factional bandwidth (FBW) of 29%. An applicability of the developed CMUT for airborne ranging is demonstrated in pulse-echo based ranging measurements, where the distance of a sound reflecting metal plate can be clearly detected by a single CMUT operated in a transceiver mode.

14 March 2018 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
TKThomas Kuenzig
Thomas Kuenzig
ADAlfons Dehe
Alfons Dehe
UKUlrich Krumbein
Ulrich Krumbein
GSGabriele Schrag
Gabriele Schrag
Maxing out the technological limits in order to satisfy the customers’ demands and obtain the best performance of micro-devices and-systems is a challenge of today’s manufacturers. Dedicated system simulation is key to investigate the potential of device and system concepts in order to identify the best design w.r.t. the given requirements. We present a tailored, physics-based system-level modeling approach combining lumped with distributed models that provides detailed insight into the device and system operation at low computational expense. The resulting transparent, scalable (i.e. reusable) and modularly composed models explicitly contain the physical dependency on all relevant parameters, thus being well suited for dedicated investigation and optimization of MEMS devices and systems. This is demonstrated for an industrial capacitive silicon microphone. The performance of such microphones is determined by distributed effects like viscous damping and inhomogeneous capacitance variation across the membrane as well as by system-level phenomena like package-induced acoustic effects and the impact of the electronic circuitry for biasing and read-out. The here presented model covers all relevant figures of merit and, thus, enables to evaluate the optimization potential of silicon microphones towards high fidelity applications.

5 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AGAkash Gupta
Akash Gupta
ABAnant Bhardwaj
Anant Bhardwaj
ABAchim Bittner
Achim Bittner
ADAlfons Dehe
Alfons Dehe
Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 μV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects is developed to identify and investigate the critical design parameters that influence system performance. The overall system exhibits a band-pass frequency response, enabling broadband operation. Based on these insights, a miniaturised photoacoustic cell is fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 s, resulting in an NNEA of 6×10−6 W cm−1 Hz−0.5. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies.

24 August 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDennis Becker
Dennis Becker
MLMoritz Littwin
Moritz Littwin
ABAchim Bittner
Achim Bittner
ADAlfons Dehe
Alfons Dehe
Recent publications on acoustic MEMS transducers present a new three-dimensional folded diaphragm that utilizes buried in-plane vibrating structures to increase the active area from a small chip volume. Characterization of the mechanical properties plays a key role in the development of new MEMS transducers, whereby established measurement methods are usually tailored to structures close to the sample surface. In order to access the lateral vibrations, extensive and destructive sample preparation is required. This work presents a new passive measurement technique that combines acoustic transmission measurements and lumped-element modelling. For diaphragms of different lengths, compliances between 0.08 × 10−15 and 1.04 × 10−15 m3/Pa are determined without using destructive or complex preparations. In particular, for lengths above 1000 µm, the results differ from numerical simulations by only 4% or less.

9 September 2025 in Gases
Verified
Journal Article
Open access
PDF file
ASAnanya Srivastava
Ananya Srivastava
RSRohan Sonar
Rohan Sonar
ABAchim Bittner
Achim Bittner
ADAlfons Dehe
Alfons Dehe
This work presents a proof of concept including simulation and experimental validations of acoustic gas sensor prototypes for trace CO2 detection up to 1 ppm. For the detection of lower gas concentrations especially, the dependency of acoustic resonances on the molecular weights and, consequently, the speed of sound of the gas mixture, is exploited. We explored two resonator types: a cylindrical acoustic resonator and a Helmholtz resonator intrinsic to the MEMS microphone’s geometry. Both systems utilized mass flow controllers (MFCs) for precise gas mixing and were also modeled in COMSOL Multiphysics 6.2 to simulate resonance shifts based on thermodynamic properties of binary gas mixtures, in this case, N2-CO2. We performed experimental tracking using Zurich Instruments MFIA, with high-resolution frequency shifts observed in µHz and mHz ranges in both setups. A compact and geometry-independent nature of MEMS-based Helmholtz tracking showed clear potential for scalable sensor designs. Multiple experimental trials confirmed the reproducibility and stability of both configurations, thus providing a robust basis for statistical validation and system reliability assessment. The good simulation experiment agreement, especially in frequency shift trends and gas density, supports the method’s viability for scalable environmental and industrial gas sensing applications. This resonance tracking system offers high sensitivity and flexibility, allowing selective detection of low CO2 concentrations down to 1 ppm. By further exploiting both external and intrinsic acoustic resonances, the system enables highly sensitive, multi-modal sensing with minimal hardware modifications. At microscopic scales, gas detection is influenced by ambient factors like temperature and humidity, which are monitored here in a laboratory setting via NDIR sensors. A key challenge is that different gas mixtures with similar sound speeds can cause indistinguishable frequency shifts. To address this, machine learning-based multivariate gas analysis can be employed. This would, in addition to the acoustic properties of the gases as one of the variables, also consider other gas-specific variables such as absorption, molecular properties, and spectroscopic signatures, reducing cross-sensitivity and improving selectivity. This multivariate sensing approach holds potential for future application and validation with more critical gas species.