We report a microresonator platform that allows room temperature detection of electron spins in volumes on the order of 100 pl, and demonstrate its utility to study low levels of dopants in perovskite oxides. We exploit the toroidal moment in a planar anapole, using a single unit of an anapole metamaterial architecture to produce a microwave resonance exhibiting a spatially confined magnetic field hotspot and simultaneously high quality-factor (Q-factor). To demonstrate the broad implementability of this design and its scalability to higher frequencies, we deploy the microresonators in a commercial electron paramagnetic resonance (EPR) spectrometer operating at 10 GHz and a NIST-built EPR spectrometer operating at 35 GHz. We report continuous-wave (CW) EPR spectra for various samples, including a dilute Mn2+-doped perovskite oxide, CaTiO3, and a transition metal complex, CuCl2.2H2O. The anapole microresonator presented here is expected to enable multifrequency EPR characterization of dopants and defects in perovskite oxide microcrystals and other volume-limited materials of technological importance.
7 December 2017 in IEEE Transactions on Electron Devices
To combat the large variability problem in resistive random access memory, current compliance elements are commonly used to limit the in-rush current during the forming operation. Regardless of the compliance element (1R-1R or 1T-1R), some degree of current overshoot is unavoidable. The peak value of the overshoot current is often used as a predictive metric of the filament characteristics and is linked to the parasitic capacitance of the test structure. The reported detrimental effects of higher parasitic capacitance seem to support this concept. However, this understanding is inconsistent with the recent successes of compliance-free ultrashort pulse forming which guarantees a maximum peak overshoot current. We use detailed circuit analysis and experimental measurements of 1R-1R and 1T-1R structures to show that the peak overshoot is independent of the parasitic capacitance while the overshoot duration is strongly dependent on the parasitic capacitance. Forming control can be achieved, in ultrashort pulse forming, since the overshoot duration is always less than the applied pulse duration. The demonstrated success of ultrashort pulse forming becomes easier to reconcile after identifying the importance of overshoot duration.
This work presents the design and measurement of a low-power wide-band cryogenic low-noise amplifier (LNA) that operates at both room and cryogenic temperatures using 16 nm FinFET technology. The LNA is packaged and measured at both room and cryogenic temperatures. It features a compact multistage cascode topology and operates between 2.2 and 6.9 GHz, with a noise figure (NF) of 0.36 dB, a peak gain of 31.4 dB, and a total dc power consumption of 4 mW at 18 K temperature.
Allan deviation provides a means to characterize the time-dependence of noise in oscillators and potentially identify the source characteristics. Measurements on a 130 nm, 7-stage ring oscillator show that the Allan deviation declines from 300 K to 150 K as expected, but surprisingly increases from 150 K to 11 K. At low temperatures, the measured Allan deviation can be well fit using a few random telegraph noise (RTN) sources over the range of a few kilohertz to a few gigahertz. Further, the RTN characteristics evolve to reveal an enhanced role in low-frequency noise at lower temperatures.
30 August 2016 in IEEE Transactions on Electron Devices
We report a new technique for the rapid measurement of full capacitance-voltage (C-V) characteristic curves. The displacement current from a 100-MHz applied sine wave, which swings from accumulation to strong inversion, is digitized directly using an oscilloscope from the MOS capacitor under test. A C-V curve can be constructed directly from this data but is severely distorted due to nonideal behavior of real measurement systems. The key advance of this paper is to extract the system response function using the same measurement setup and a known MOS capacitor. The system response correction to the measured C-V curve of the unknown MOS capacitor can then be done by simple deconvolution. No deskewing and/or leakage current correction is necessary, making it a very simple and quick measurement. Excellent agreement between the new fast C-V method and C-V measured conventionally by an LCR meter is achieved. The total time required for measurement and analysis is approximately 2 s, which is limited by our equipment.