11 June 2025 in Measurement Science and Technology
Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the actuation improves AC amplitude stability from 8 in the open loop design to 1 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.
21 November 2025 in Classical and Quantum Gravity
Releasing the test mass (TM) is a critical phase of inertial sensors for gravitational wave detection. The grabbing positioning and release mechanism inevitably generates large initial momentum making TM capture control particularly challenging. To maximize the controllable range, this paper presents a time-division control strategy for the TM release phase. Simulation results show that the proposed method significantly enlarges the capture range, enabling robust capture under large initial state.
16 January 2026 in Classical and Quantum Gravity
The space inertial sensor is a critical payload in space-based gravitational wave detection missions. The test mass, serving as the gravitational reference, should be maintained at the center of its electrode housing through AC electrostatic control and drag-free attitude control. However, excessive electrostatic actuation cross-coupling between degrees of freedom can significantly deteriorate the residual acceleration performance along the sensitive axis (xaxis). This paper investigates the influence of carrier frequency selection on the electrostatic actuation noise coupling from the ϕ-axis to the x-axis. The analysis shows that to suppress the coupling coefficient below 2 × 10 -3 within the 0.1 mHz-1 Hz band, the sum and difference of the carrier frequencies should be integer multiples of the desired force/torque update rate f s . Furthermore, the difference frequency should exceed 180 Hz with a deviation smaller than 0.4% to satisfy TianQin's requirement. These conclusions are validated through a dedicated Simulink simulation platform. The proposed frequency configuration guideline offers a clear basis for AC feedback design in inertial sensors, effectively suppressing cross-coupling and enhancing low-frequency performance for future space-based gravitational wave missions.
10 March 2026 in Classical and Quantum Gravity
Space inertial sensors often employ AC feedback control to suppress acceleration noise introduced by stray potential fluctuations through DC voltage. The requirement is to provide substantial control force without losing control accuracy, thereby enhancing the system’s capability to handle various operational conditions. This paper proposes a phase-tunable AC feedback control strategy for AC actuators. The actuator outputs a superimposed signal consisting of an AC bias voltage, a translational feedback voltage, and a rotational feedback voltage, all with the same frequency and constant amplitude. By independently adjusting the phase differences between the translational voltage and the ac bias voltage, as well as between the rotational voltage and the bias voltage, closed-loop control over different degrees of freedom of the test mass (TM) is achieved. Theoretical analysis demonstrates that this control strategy significantly expands the control range of closed-loop control for space inertial sensors without altering the existing hardware circuit while maintaining constant electrostatic stiffness of the TM at its equilibrium position. Further simulation modeling validates the theoretical conclusions and shows that the proposed phase-tunable AC feedback control strategy enhances the robustness of the electrostatic suspension control system against large disturbances while maintaining displacement control accuracy.
17 August 2026 in Measurement Science and Technology
The high-precision inertial sensor is a key technology for space-based gravitational wave detection missions. AC high-voltage electrostatic actuators with an output capability of hundreds of volts are required to capture and control the test mass after its initial release by the locking mechanism, and this is critical for achieving scientific mode. This paper proposes high-voltage electrostatic actuators with a step-up transformer, which could eliminate the need for a high-voltage power supply. The transformer is specially designed to provide an amplification of around 15 and a frequency range of over 50–1000 Hz. Testing has confirmed that the actuator can deliver a high-voltage output of approximately 150 V. Its amplification coefficient exhibits a response relationship with changes in input voltage and frequency, and the resulting minor nonlinearity does not affect capture control after closed-loop compensation. This work provides an alternative scheme for high-voltage electrostatic actuators.
17 March 2026 in SSRN Electronic Journal
Space-borne gravitational wave detection demands an inertial sensor with a residual acceleration resolution for the test mass (TM) on the order of 10-15 m/s2/Hz1/2. To suppress electrostatic control noise, this study proposes a minimum-stiffness electrostatic actuation algorithm. The performance of the proposed method is found to be scenario-dependent: under small displacement offsets, it significantly reduces the average electrostatic stiffness and actuation coupling noise by over an order of magnitude compared to traditional constant-stiffness algorithms, thereby enabling TM residual acceleration to surpass the mission requirements. Conversely, under large offset conditions, the constant-stiffness algorithm demonstrates superior robustness by maintaining stable residual acceleration below the prescribed threshold.