Yiyan Jiang

Yiyan Jiang

Auto-generated profile, based on publicly available information

Yiyan Jiang

National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and technology, Wuhan 430074, People’s Republic of China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
JLJinfeng Lu
Jinfeng Lu
YJYiyan Jiang
Yiyan Jiang
JZJunjie Zhou
Junjie Zhou
MHMing Hu
Ming Hu
XYXiaotian Yang
Xiaotian Yang
ZZZebing Zhou
Zebing Zhou
Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the Σ − Δ noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 ppm Hz − 1 / 2 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the Σ − Δ actuation improves AC amplitude stability from 8 ppm Hz − 1 / 2 in the open loop design to 1 ppm Hz − 1 / 2 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.

13 January 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
YJYiyan Jiang
Yiyan Jiang
JLJinfeng Lu
Jinfeng Lu
COChaoli Ouyang
Chaoli Ouyang
HZHongtao Zhou
Hongtao Zhou
MHMing Hu
Ming Hu
ZZZebing Zhou
Zebing Zhou
To realize the free falling test mass (TM) in gravitational wave detection in space, an alternative current (AC) electrostatic control strategy is proposed and developed. It is significant to test and verify the AC control actuation scheme on the ground. In this paper, a two-stage torsion pendulum is used to test the performance of the AC control actuator of inertial sensor for Tianqin project. First, the pendulum facility combined with a TM, a capacitive position sensor and an AC control actuator is constructed. Experimental results show that the sensitivities of the pendulum achieve 4.2 × 10 −11 N Hz −1/2 at 6 mHz and 1.6 × 10 −13 Nm Hz −1/2 at 15 mHz, respectively, and the pendulum provides a chance to realize the performance test of two degree-of-freedom sensitivities of the actuator, experimental verification of AC control strategy and so on, which is first reported to test performance of the AC control actuator of a space inertial sensor on the ground.

5 June 2026 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
COChaoli Ouyang
Chaoli Ouyang
YJYiyan Jiang
Yiyan Jiang
JLJinfeng Lu
Jinfeng Lu
HFHongyi Fu
Hongyi Fu
CWChengrui Wang
Chengrui Wang
ZZZebing Zhou
Zebing Zhou
The inertial sensor (IS) is one of the most critical units in space-based gravitational wave detection projects. Due to the machining process and assembly errors of the IS head (ISH) in the IS, the electrostatic force in the non-sensitive direction of the test mass (TM) will produce a cross-coupling effect in the sensitive direction, which couples the non-sensitive axis actuation acceleration into an acceleration noise along the sensitive axis. The path that non-sensitive axis force and torque influence the residual acceleration of the sensitive axis, via the capacitance gradient, is constructed. A capacitance measurement device equipped with an ISH and a three-terminal mode to ensure the excellent measurement performance was constructed to measure the nominal capacitance and the derivative of the sensing/actuation capacitance along the six degrees of freedom. The simulation values are consistent with the experimental values within the error range. The electrostatic cross-coupling from non-sensitive directions into the sensitive direction, on the order of 10 −3 –10 −4 , is evaluated via the experimental capacitance gradients. The residual disturbance acceleration noise of the sensitive axis on the TM contributed by the non-sensitive axis actuation acceleration noise is approximately 8.0 × 10 −17 m s −2 Hz −1/2 around 1 mHz.

14 September 2026 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
YJYiyan Jiang
Yiyan Jiang
MHMing Hu
Ming Hu
LLLi Liu
Li Liu
SWShuchao WU
Shuchao WU
ZZZebing Zhou
Zebing Zhou
Electrostatic stiffness is a key parameter governing space inertial sensor, and its precise characterization via applied actuation voltages is critical for determining the residual acceleration of the test mass along the sensitive axis. In this paper, we investigate the dependence of this stiffness on the maximum actuation range within a dedicated model. A closed-loop calibration experiment utilizing a custom-designed two-stage torsion pendulum equipped with capacitive sensors and an AC feedback control system was performed. For electrostatic stiffness near 10 −4 N m −1 , measurements agree with theoretical predictions within a 1.6% deviation. The stiffness exhibits direct proportionality to both the maximum actuation force and torque. These results validate the constant stiffness model and provide guidelines for optimizing in-orbit electrostatic control parameters.