Junjie Zhou

Junjie Zhou

Auto-generated profile, based on publicly available information

Junjie Zhou

National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and technology, Wuhan 430074, People’s Republic of China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2022 in Aerospace
Verified
Journal Article
Open access
PDF file
JZJunjie Zhou
Junjie Zhou
APAiping PANG
Aiping PANG
HLHui Liu
Hui Liu
HZHongbo Zhou
Hongbo Zhou
XNXiang Niu
Xiang Niu
The space gravitational wave detection mission has put forward multiple performance requirements for micro-newton thrusters, such as “fast response, high resolution, and low noise”. In order to solve the problem that the traditional open-loop propulsion system can hardly meet the high-precision performance, the microwave ion thruster with high accuracy and controllability of thrust estimation is adopted as the research object, and the precision feedback control method combining analog circuit and digital control technology is adopted to achieve a resolution of less than 0.1 μN, fast response of 20 ms, and 10−3~1 Hz frequency band noise less than 0.05 μN/Hz1/2 of the thrust performance. Experimental results show that, compared with open-loop regulation, the feedback control can effectively suppress various noises and disturbances caused by device temperature drift and complex operating characteristics of the thruster, and the anti-aliasing filter scheme adopted in this paper can suppress the folding of high-frequency data in the low- and medium-frequency bands during the digital control process, while it can effectively improve the system performance and reduce the impact of thrust noise. The feedback control strategy proposed in this paper verifies the possibility of a microwave ion thruster as an actuator for super “static and precise” space experiment satellites and provides a feasible solution for the application of a microwave ion thruster in deep space science experiment missions such as gravitational wave detection.

11 June 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
JLJinfeng Lu
Jinfeng Lu
YJYiyan Jiang
Yiyan Jiang
JZJunjie Zhou
Junjie Zhou
MHMing Hu
Ming Hu
XYXiaotian Yang
Xiaotian Yang
ZZZebing Zhou
Zebing Zhou
Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the Σ − Δ noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 ppm Hz − 1 / 2 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the Σ − Δ actuation improves AC amplitude stability from 8 ppm Hz − 1 / 2 in the open loop design to 1 ppm Hz − 1 / 2 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.

21 November 2025 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
JZJunjie Zhou
Junjie Zhou
AZAnnan Zhou
Annan Zhou
HMHongyu Mao
Hongyu Mao
CZChujie Zhang
Chujie Zhang
JLJinfeng Lu
Jinfeng Lu
ZZZebing Zhou
Zebing Zhou
Releasing the test mass (TM) is a critical phase of inertial sensors for gravitational wave detection. The grabbing positioning and release mechanism inevitably generates large initial momentum making TM capture control particularly challenging. To maximize the controllable range, this paper presents a time-division control strategy for the TM release phase. Simulation results show that the proposed method significantly enlarges the capture range, enabling robust capture under large initial state.

12 December 2020 in Complexity
Verified
Journal Article
Open access
PDF file
APAiping PANG
Aiping PANG
ZHZhu Hui
Zhu Hui
JZJunjie Zhou
Junjie Zhou
ZHZhen He
Zhen He
JYJing Yang
Jing Yang
Aiming at the oscillation suppression of spacecraft with large flexible appendages, we propose a control strategy using H∞ control. The weighting functions are designed for the specific flexible modes of the spacecraft and the frequency of harmonic interference in its operating environment. Taking into account the structural uncertainty of systematic modeling and the comprehensive performance requirements of system bandwidth constraint and attitude stability, the H∞ comprehensive performance matrix is constructed. A space telescope with a large flexible solar array is presented as an illustrative example, and a control design that meets the requirement for pointing accuracy is proposed. The simulation results show that the designed controller satisfies the requirements of attitude stability and high pointing accuracy and has effectively suppressed the disturbance of endemic frequency. The design scheme and selection method of the weight function shown in this paper can be a reference for the controller design for oscillation suppression of this type of spacecraft with flexible structures.

22 May 2026 in Measurement
Verified
Journal Article
Closed access
JZJunjie Zhou
Junjie Zhou
AZAnnan Zhou
Annan Zhou
COChaoli Ouyang
Chaoli Ouyang
JLJinfeng Lu
Jinfeng Lu
CZChujie Zhang
Chujie Zhang
ZZZebing Zhou
Zebing Zhou

17 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JZJunjie Zhou
Junjie Zhou
AZAnnan Zhou
Annan Zhou
COChaoli Ouyang
Chaoli Ouyang
JLJinfeng Lu
Jinfeng Lu
CZChujie Zhang
Chujie Zhang
ZZZebing Zhou
Zebing Zhou
Space-borne gravitational wave detection demands an inertial sensor with a residual acceleration resolution for the test mass (TM) on the order of 10-15 m/s2/Hz1/2. To suppress electrostatic control noise, this study proposes a minimum-stiffness electrostatic actuation algorithm. The performance of the proposed method is found to be scenario-dependent: under small displacement offsets, it significantly reduces the average electrostatic stiffness and actuation coupling noise by over an order of magnitude compared to traditional constant-stiffness algorithms, thereby enabling TM residual acceleration to surpass the mission requirements. Conversely, under large offset conditions, the constant-stiffness algorithm demonstrates superior robustness by maintaining stable residual acceleration below the prescribed threshold.