Yaik-Wah Lim

Yaik-Wah Lim

Auto-generated profile, based on publicly available information

Yaik-Wah Lim

Department of Architecture, Faculty of Built Environment and Surveying, Universiti Teknologi Malaysia, Johor Bahru, Malaysia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Building and Environment
Verified
Journal Article
Closed access
YLYaik-Wah Lim
Yaik-Wah Lim
Heap-Yih ChongHeap-Yih Chong
Heap-Yih Chong
PLPhilip C.H. Ling
Philip C.H. Ling
CTCher Siang Tan
Cher Siang Tan

16 January 2021 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
MAMoses Iorakaa Ayoosu
Moses Iorakaa Ayoosu
YLYaik-Wah Lim
Yaik-Wah Lim
PAU CHUNG LENGPAU CHUNG LENG
PAU CHUNG LENG
OIOlusegun Moses Idowu
Olusegun Moses Idowu
A base case model is a more potent dose for applied research; the passive architectural design for sustainability requires optimised experiments. However, experimenting with physical developments require construction and deconstruction until they achieved the optimal scenario. These wastes resources and time; hence, base models' development as useful instruments in the optimisation design process is desirable. Lecture theatres in universities have no specific design model whereby optimising one may not apply to the other. Therefore, this research evaluated a base model for lecture theatre regarding spatial configuration, daylighting potentials, and optimised window-to-wall ratio (WWR) for tropical daylighting. A study of ten existing lecture theatres in eight universities within eight states in Nigeria's hot-humid climate was analysed descriptively for the base model. The study employed Simulations with IES-VE software. The daylighting performance analysis adopted the daylighting rule of thumb, daylight factor, work plane illuminance (WPI), and WPI ratio. The results show that a typical lecture theatre in the study area has a dimensional configuration of 12×20 m floor plan, 6 m ceiling height, and a window wall ratio (WWR) of 13%. In the deduced base model, 4H was required for adequate daylighting against the thumb's 2.5 H daylighting rule. The research concludes a low window-wall ratio with poor daylighting quality and quantities in the base model; therefore, it implies that the daylighting was not a criterion in the designs. However, the experiment revealed a progression in daylighting performance with an increase in WWR from the base case until 30% WWR. Beyond that, there was a decline in the daylighting performance. Therefore, 30% WWR was optimal for daylighting performance in lecture theatre retrofitting within the tropical climate.

10 April 2019 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
Abdelhakim MesloubAbdelhakim Mesloub
Abdelhakim Mesloub
YLYaik-Wah Lim
Yaik-Wah Lim
MKMohd Zin Kandar
Mohd Zin Kandar
Daylight quality and quantity in Algerian schools show serious problems in ensuring visual comfort of students and teachers. Some problems are due to window design, which leads to excessive amount of sunlight penetration into the classrooms. The consequences are glare and heat gain. This study investigates the effective glazing pattern for classroom to achieve optimum daylight performance and visual comfort in Algerian classrooms. Field measurements of typical classrooms were carried out in a selected school in Algeria during solstice summer (under clear sky condition) and solstice winter (under overcast sky condition). The data of outdoor daylight illuminance were used to validate Integrated Environment Solution Virtual Environment (IESVE) daylight simulation. This study used three different glazing types, namely, clear, tint and reflective glass with different glazing proportions, subsequently, seven patterns of glazing window design were used for an extensive simulation exercise. The results of the investigation from the site measurements show that the work plane illuminance was found to be beyond the range of 300 lux to 500 lux, which exceeded recommended value, except for the south-east orientation with clerestory typology, which were recorded at 2.98% of daylight factor, in contrast the daylight uniformity in tested classrooms is appropriate. Furthermore, the simulation revealed that combination of 75% clear glass and 25% reflective glass with 30% wall-to-window ratio has achieved 41.41% during winter and 47.82% during summer of Useful daylight illuminance. The use of different glazing configurations shows a significant improvement on daylight distribution and the reduction of glare comparing to the reference model. However, such improvement in the quality and quantity of daylighting was inadequate which arises the need of further enhancement. Header of solarlits.com

28 November 2024 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
TSTaki Eddine Seghier
Taki Eddine Seghier
CKChavanont Khosakitchalert
Chavanont Khosakitchalert
Ziwen LiuZiwen Liu
Ziwen Liu
COChukwuka Christian Ohueri
Chukwuka Christian Ohueri
YLYaik-Wah Lim
Yaik-Wah Lim
AZAhmad Fahmi Bin Zainazlan
Ahmad Fahmi Bin Zainazlan

9 June 2019 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
Abdelhakim MesloubAbdelhakim Mesloub
Abdelhakim Mesloub
MKMohd Zin Kandar
Mohd Zin Kandar
YLYaik-Wah Lim
Yaik-Wah Lim
Building integrated photovoltaic (BIPV) energy has now become one of the most significant renewable energy alternatives for providing natural daylight and clean energy. As such, this study was conducted for the first time in Algeria to experimentally evaluate the BIPV window energy and lighting energy savings of a typical office building under the semi-arid climate condition. Apart from using the Energy Plus and Integrated Environment Solution-Virtual environment (IES-VE) energy simulation tools in the experimental validation, the daylighting control method and the dynamic Useful Daylight Illuminance (UDI) were also utilized to analyse the daylighting performance as well as the lighting energy of BIPV windows with different transparency levels at various cardinal orientations. The field measurements had revealed the overall energy model to be consistent and in good agreement with the EnergyPlus and the IESVE simulation models, where the tested PV module was found to have provided not only a 20% Visible Light Transmittance (VLT) of uniformed daylight with low illuminance level, but also thermal comfort and a considerable amount of clean energy. The simulated results had demonstrated a substantial improvement in cooling energy and glare reduction of the PV modules as compared to the base-model, where the only BIPV window configuration was achieved good area of UDI300-700lux is facing the South orientation and 30%VLT. In conclusion, the application of the thin film BIPV windows with different transparency and orientation levels can thus be regarded as an effective solution for minimizing the lighting energy consumption through its energy production instead of daylighting utilization. Header of solarlits.com