Ghanshyamsinh Gohil

Ghanshyamsinh Gohil

Auto-generated profile, based on publicly available information

Ghanshyamsinh Gohil

Department of Electrical Engineering, The University of Texas at Dallas, Richardson, TX, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Open access
VIVishnu Mahadeva Iyer
Vishnu Mahadeva Iyer
SGSrinivas Gulur
Srinivas Gulur
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
SBSubhashish Bhattacharya
Subhashish Bhattacharya

13 September 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AAAnup Anurag
Anup Anurag
SASayan Acharya
Sayan Acharya
YPYos Prabowo
Yos Prabowo
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
SBSubhashish Bhattacharya
Subhashish Bhattacharya
Medium Voltage (MV) Silicon Carbide (SiC) devices have opened up new areas of applications which were previously dominated by silicon based IGBTs. From the perspective of a power converter design, the development of MV SiC devices eliminates the need for series connected architectures, control of multilevel converter topologies which are necessary for MV applications, and the inherent reliability issues associated with it. However, when SiC devices are used in these applications, they are exposed to a high peak stress (5 kV to 10 kV) and a very high dv/dt (10 kV/ μs to 100 kV/ μs). Using these devices calls for a gate driver with dc-dc isolation stage which has ultra-low coupling capacitance in addition to be able to withstand the high isolation voltage. This paper presents a new MV gate driver design to address these issues while maintaining a minimal footprint for the gate driver. A medium voltage isolation transformer is designed with a low inter-winding capacitance, while maintaining the clearance, creepage, as well as insulation standards. A dc isolation test has been performed to validate the integrity of the insulating material. The key features include low input common mode current, and a short circuit protection scheme specifically designed for 10 kV SiC MOSFETs. The performance of the gate driver is evaluated using double pulse tests and continuous tests. Experimental results validate the advantages of the gate driver and its application for medium voltage SiC devices exhibiting very high dv/dt. The proposed gate driver concept is aimed at providing an efficient and reliable method to drive MV SiC devices.

16 July 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
RMRamkrishan Maheshwari
Ramkrishan Maheshwari
LBLorand Bede
Lorand Bede
Tamás KerekesTamás Kerekes
Tamás Kerekes
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Parallel voltage-source converters (VSCs) require an inductive filter to suppress the circulating current. The size of this filter can be minimized by reducing either the maximum value of the flux linkage or the core losses. This paper presents a modified discontinuous pulsewidth modulation (DPWM) scheme to reduce the maximum value of the flux linkage and the core losses in the circulating current filter. In the proposed PWM scheme, the dwell time of an active vector is divided within a half-carrier cycle to ensure simultaneous occurrence of the same zero vectors in both VSCs. A function to decide the ratio of the dwell time of the divided active vector is also presented. The effect of the proposed PWM scheme on the maximum value of the flux linkage and the core losses is analyzed and compared with that of the space vector modulation and 60$^\circ$ clamped DPWM schemes. The analytical expressions for the maximum value of the flux linkage are derived for each of these PWM schemes. In addition, the effect of the proposed PWM scheme on the line current ripple and the switching losses is also analyzed and compared. To verify the analysis, experimental results are presented, which prove the effectiveness of the proposed PWM scheme.

10 July 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
LBLorand Bede
Lorand Bede
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Tamás KerekesTamás Kerekes
Tamás Kerekes
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
The interleaving of the carrier signals of the parallel voltage-source converters can reduce the harmonic content in the resultant switched output voltages. As a result, the size of the line filter inductor can be reduced. However, in addition to the line filter, an inductive filter is often required to suppress the circulating current. The size of the system can be reduced by integrating these two inductors in a single magnetic component. An integrated inductor, which combines the functionality of both the line filter inductor and the circulating current filter inductor, is presented. The pulsewidth modulation (PWM) schemes to reduce the flux in some parts of the integrated inductor are also analyzed. The flux reduction achieved by using these schemes is demonstrated by comparing these schemes with the conventional space vector modulation and the 60° clamped discontinuous PWM scheme. The impact of these PWM schemes on the harmonic performance is also discussed. Simulation and experimental results are presented to validate the analysis.

27 January 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
LBLorand Bede
Lorand Bede
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Tamás KerekesTamás Kerekes
Tamás Kerekes
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
The voltage source converters (VSCs) are often connected in parallel in a wind energy conversion system to match the high power rating of the modern wind turbines. The effect of the interleaved carriers on the harmonic performance of the parallel connected VSCs is analyzed in this paper. In order to achieve low-switching losses, the 60° clamp discontinuous pulsewidth modulation (DPWM1) is used to modulate the VSCs. A step-by-step design procedure of the line filter, which ensures the desired harmonic performance under all operating conditions, is presented. The analytical harmonic solution for the two parallel interleaved VSCs is derived in order to obtain the worst case voltage magnitude of the individual harmonic components. The required value of the filter admittance for the specific harmonic component is obtained by using the worst case voltage magnitude and the allowable harmonic injection limit. In order to achieve the desired filter performance with optimal values of the filter parameters, the use of an LC trap branch with the conventional LCL filter is proposed. The expressions for the resonant frequencies of the proposed line filter are derived and used in the design to selectively choose the values of the line filter components. The analysis and design methodology are also verified experimentally.

1 September 2013
Verified
Conference Paper
Closed access
RPRafael Pena-Alzola
Rafael Pena-Alzola
GGGhanshyamsinh Gohil
Ghanshyamsinh Gohil
LMLaszlo Mathe
Laszlo Mathe
MLMarco Liserre
Marco Liserre
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
While the use of power electronics based Smart Transformer (ST) is becoming a reality in traction applications, and it has been considered as an interesting option for interfacing different transmission systems, the possibility to use it in distribution systems is still considered futuristic. Replacing primary distribution transformers with ST can lead to more flexible handling of the distribution feeders, while replacing secondary distribution transformers can allow decoupling of distribution network. This paper reviews different power converter solutions for the ST focusing on modularity, control and communication needs, to meet high reliability requirements. Five topologies for the ST are considered and compared.