Pierluigi Bellutti

Pierluigi Bellutti

Auto-generated profile, based on publicly available information

Pierluigi Bellutti

Bruno Kessler Foundation, Via Sommarive 18, 38123 Trento, Italy

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndrea Gaiardo
Andrea Gaiardo
Barbara FabbriBarbara Fabbri
Barbara Fabbri
Vincenzo GuidiVincenzo Guidi
Vincenzo Guidi
PBPierluigi Bellutti
Pierluigi Bellutti
AGAlessio Giberti
Alessio Giberti
GZGiulia Zonta
Giulia Zonta
This work aims at a broad overview of the results obtained with metal-sulfide materials in the field of chemoresistive gas sensing. Indeed, despite the well-known electrical, optical, structural and morphological features previously described in the literature, metal sulfides present lack of investigation for gas sensing applications, a field in which the metal oxides still maintain a leading role owing to their high sensitivity, low cost, small dimensions and simple integration, in spite of the wide assortment of sensing materials. However, despite their great advantages, metal oxides have shown significant drawbacks, which have led to the search for new materials for gas sensing devices. In this work, Cadmium Sulfide and Tin (IV) Sulfide were investigated as functional materials for thick-film chemoresistive gas-sensors fabrication and they were tested both in thermo- and in photo-activation modes. Furthermore, electrical characterization was carried out in order to verify their gas sensing properties and material stability, by comparing the results obtained with metal sulfides to those obtained by using their metal-oxides counterparts. The results highlighted the possibility to use metal sulfides as a novel class of sensing materials, owing to their selectivity to specific compounds, stability, and the possibility to operate at room temperature.

6 November 2015 in Micromachines
Verified
Journal Article
Open access
PDF file
RCROSSANA CECCHI
ROSSANA CECCHI
Matteo VerottiMatteo Verotti
Matteo Verotti
Roberto CapataRoberto Capata
Roberto Capata
ADAlden Dochshanov
Alden Dochshanov
GBGiovanni Battista Broggiato
Giovanni Battista Broggiato
Nicola Pio BelfioreNicola Pio Belfiore
Nicola Pio Belfiore
Although tissue and cell manipulation nowadays is a common task in biomedical analysis, there are still many different ways to accomplish it, most of which are still not sufficiently general, inexpensive, accurate, efficient or effective. Several problems arise both for in vivo or in vitro analysis, such as the maximum overall size of the device and the gripper jaws (like in minimally-invasive open biopsy) or very limited manipulating capability, degrees of freedom or dexterity (like in tissues or cell-handling operations). This paper presents a new approach to tissue and cell manipulation, which employs a conceptually new conjugate surfaces flexure hinge (CSFH) silicon MEMS-based technology micro-gripper that solves most of the above-mentioned problems. The article describes all of the phases of the development, including topology conception, structural design, simulation, construction, actuation testing and in vitro observation. The latter phase deals with the assessment of the function capability, which consists of taking a series of in vitro images by optical microscopy. They offer a direct morphological comparison between the gripper and a variety of tissues.

1 August 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ABAlvise Bagolini
Alvise Bagolini
AGAndrea Gaiardo
Andrea Gaiardo
Michele CrivellariMichele Crivellari
Michele Crivellari
EDEvgeny Demenev
Evgeny Demenev
RBRuben Bartali
Ruben Bartali
PBPierluigi Bellutti
Pierluigi Bellutti

1 February 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AGAndrea Gaiardo
Andrea Gaiardo
BFB. Fabbri
B. Fabbri
AGA. Giberti
A. Giberti
MVMatteo Valt
Matteo Valt
SGS. Gherardi
S. Gherardi
EDE. Demenev
E. Demenev

30 December 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
Paolo Di GiamberardinoPaolo Di Giamberardino
Paolo Di Giamberardino
ABAlvise Bagolini
Alvise Bagolini
PBPierluigi Bellutti
Pierluigi Bellutti
Imre RudasImre Rudas
Imre Rudas
Matteo VerottiMatteo Verotti
Matteo Verotti
Nicola Pio BelfioreNicola Pio Belfiore
Nicola Pio Belfiore
As many studies show, there is a relation between the tissue’s mechanical characteristics and some specific diseases. Knowing this relationship would help early diagnosis or microsurgery. In this paper, a new method for measuring the viscoelastic properties of soft materials at the microscale is proposed. This approach is based on the adoption of a microsystem whose mechanical structure can be reduced to a compliant four bar linkage where the connecting rod is substituted by the tissue sample. A procedure to identify both stiffness and damping coefficients of the tissue is then applied to the developed hardware. Particularly, stiffness is calculated solving the static equations of the mechanism in a desired configuration, while the damping coefficient is inferred from the dynamic equations, which are written under the hypothesis that the sample tissue is excited by a variable compression force characterized by a suitable wave form. The whole procedure is implemented by making use of a control system.

24 March 2018 in Actuators
Verified
Journal Article
Open access
PDF file
CPCristina Potrich
Cristina Potrich
LLLorenzo Lunelli
Lorenzo Lunelli
ABAlvise Bagolini
Alvise Bagolini
PBPierluigi Bellutti
Pierluigi Bellutti
CPCecilia Pederzolli
Cecilia Pederzolli
Nicola Pio BelfioreNicola Pio Belfiore
Nicola Pio Belfiore
The demand of miniaturized, accurate and robust micro-tools for minimally invasive surgery or in general for micro-manipulation, has grown tremendously in recent years. To meet this need, a new-concept comb-driven microgripper was designed and fabricated. Two microgripper prototypes differing for both the number of links and the number of conjugate surface flexure hinges are presented. Their design takes advantage of an innovative concept based on the pseudo-rigid body model, while the study of microgripper mechanical potentialities in different configurations is supported by finite elements’ simulations. These microgrippers, realized by the deep reactive-ion etching technology, are intended as micro-tools for tissue or cell manipulation and for minimally invasive surgery; therefore, their biocompatibility in terms of protein fouling was assessed. Serum albumin dissolved in phosphate buffer was selected to mimic the physiological environment and its adsorption on microgrippers was measured. The presented microgrippers demonstrated having great potential as biomedical tools, showing a modest propensity to adsorb proteins, independently from the protein concentration and time of incubation.