André T. Queiroz

André T. Queiroz

Auto-generated profile, based on publicly available information

André T. Queiroz

Fluminense Federal University, Niteri, RJ, Brazil

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AQAndré T. Queiroz
André T. Queiroz
ABAlexandre Bitencourt
Alexandre Bitencourt
CNCauê Nogueira
Cauê Nogueira
FMFlávio G. R. Martins
Flávio G. R. Martins
FDFernando Jorge Monteiro Dias
Fernando Jorge Monteiro Dias
GSGuilherme Goncalves Sotelo
Guilherme Goncalves Sotelo
A Hybrid Fault Current Limiter (HFCL) is a device that combines the properties of both Superconducting Fault Current Limiter (SFCL) and Solid-State Fault Current Limiter (SSFCL). This combination aims to provide the fast response time typically associated with SFCLs and simultaneously provide the capacity to withstand longer limitation time and reliable application under high voltages, as found in SSFCLs. In this context, an HFCL prototype was tested to analyze its performance and compare its characteristics with those of the SFCL and the SSFCL modules separately. This work aims to demonstrate that the HFCL presents a high level of protection, besides being more compact and cost-effective compared to SFCLs, since the proposed hybrid device can be designed using less HTS material than common resistive SFCL. Experimental tests were made to analyze the current limitation capacity for the three FCLs. The results showed that the HFCL could reduce the fault current with a reliable fault detection system.

3 February 2021 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
MSMarcelo F. de Souza
Marcelo F. de Souza
AQAndré T. Queiroz
André T. Queiroz
GSGuilherme Goncalves Sotelo
Guilherme Goncalves Sotelo
PMPaulo Roberto Duailibe Duailibe Duailibe Monteiro
Paulo Roberto Duailibe Duailibe Duailibe Monteiro
MFmarcio Fortes
marcio Fortes
APAlexander Polasek
Alexander Polasek

1 October 2017 in CIRED - Open Access Proceedings Journal
Verified
Journal Article
Open access
LOLorenna Oliveira
Lorenna Oliveira
MFMarcio Fortes
Marcio Fortes
DCDayana Carvalho
Dayana Carvalho
RTRodrigo Tomaz
Rodrigo Tomaz
AFAdriano Fragoso
Adriano Fragoso
AQAndré Queiroz
André Queiroz
It is known that the light emitting diode lamps have taken space in the residential, commercial and industrial lighting systems. This occurs because of its high cost being reduced over the years. Furthermore, it is also possible to observe an increase in the efficiency of them, bearing the fluorescent and incandescent lamps to disuse. This study that follows proposes to study how changing bulbs can influence, in terms of power quality, the system. Therefore, this study is based on measurements of the total harmonic distortion and the harmonic currents generated by the groups of lamps to analyse the evolution of their diversity factor. In addition, this work also investigated aspects such as lighting efficiency and heating generation.

1 June 2021 in Journal of Microwaves, Optoelectronics and Electromagnetic Applications
Verified
Journal Article
Open access
HMHenrique K. Miyamoto
Henrique K. Miyamoto
AQAndré T. Queiroz
André T. Queiroz
DDDaniel H. N. Dias
Daniel H. N. Dias
BFBruno W. França
Bruno W. França
FSFelipe Sass
Felipe Sass
GSGuilherme Goncalves Sotelo
Guilherme Goncalves Sotelo

1 May 2018
Verified
Conference Paper
Closed access
CSC. Salas
C. Salas
DGDaniel Guillen
Daniel Guillen
Frederic TrillaudFrederic Trillaud
Frederic Trillaud
AQA. T. Queiroz
A. T. Queiroz
GSG.G. Sotelo
G.G. Sotelo
This paper presents the implementation of a simple model of resistive Superconducting Fault Current Limiters (r-ScFCL) based on High Temperature Superconductor (HTS) in the software ATP/EMTP for different transient conditions appearing in distribution networks. The use of fault current limiters (FCL) is rather appealing since they can provide reduction of the short-circuit levels during faults while consuming negligible power in nominal regime. Thus far, a lot of efforts have been dedicated to the design of the equipment and lately only a few works have been focused on the impact of the device in the electrical networks. Topics of interest for the electrical sector cover the study of protection coordination and transient analysis during fault conditions. Both topics ought to be studied from the perspective of power system engineering including new technologies such as ScFCL, for instance. In the present work, part of this effort is carried out. A simplified r-ScFCL model is adopted to evaluate the dynamic performance of a given r-ScFCL under different transient conditions such as faults, transformer energisations and re-closing for distribution systems.

1 May 2018
Verified
Conference Paper
Closed access
TLT. S. Lessa
T. S. Lessa
GSG. G. Sotelo
G. G. Sotelo
MFmarcio Fortes
marcio Fortes
AQA. T. Queiroz
A. T. Queiroz
SGS. Gomes
S. Gomes
RMR. S. Maciel
R. S. Maciel
With increased demand, it is often necessary to increase the power supplied or to insert new points of power generation in the distribution network. However, the short-circuit levels may increase in network, which requires to simulating these new conditions in robust and reliable software. This paper shows a comparison between the results obtained by two specific software for electric power networks: the Open Distribution System Simulator (OpenDSS) and the Alternative Transients Program (ATP). The simulated model considers data from a real distribution system, located in Brazilian city (Armações dos Búzios). The results were compared with obtained data by the two software, for some values of simulated voltages and short-circuits in steady state. The simulated results are similar, which allows the validation of the modeled network.