Muhammad Yusha Firdaus

Muhammad Yusha Firdaus

Auto-generated profile, based on publicly available information

Muhammad Yusha Firdaus

National Research and Innovation Agency (BRIN), Indonesia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2022
Verified
Conference Paper
Open access
MFMuhammad Yusha Firdaus
Muhammad Yusha Firdaus
DWDena Karunianto Wibowo
Dena Karunianto Wibowo
MHMaratul Hamidah
Maratul Hamidah
RURyan Prasetya Utama
Ryan Prasetya Utama
MDMustika Fitriana Dewi
Mustika Fitriana Dewi
EPEdhi Purnomo
Edhi Purnomo
The advantages of optical fiber sensors, including fiber bragg grating (FBG) sensors, e.g. greater sensitivity, immunity to electromagnetic interference (EMI) and radio frequency interference (RFI), versatility, reliability, compatibility to optical communication and telemetry, reduced cost, reduced size, and reduced weight have been very well known. In particular, the FBG sensors have been widely utilized in many fields such as in structural health monitoring, oil and gas, civil industry, medical and space equipment. In this paper we develop a model of FBG sensors embedded fiber optic communication (FOC) system by using OptiSystem v.18. The bit error rate (BER) and Q-factor analysis as results of the effect of two FBG sensors on telecommunication channels, in which the sensors are integrated into a single fiber optic communication (FOC) with 80 km of fiber optic length. The results show that even with 2 sensors embedded in FOC system, the min BER and max Q factor of the system are still in good conditions with values of 4.35x 10-7 and 4.87 respectively.

8 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
RDReza Diharja
Reza Diharja
SRSasono Rahardjo
Sasono Rahardjo
MHMaratul Hamidah
Maratul Hamidah
MFMuhammad Yusha Firdaus
Muhammad Yusha Firdaus
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
This research presents the results of laboratory nonlinear characterization of a diaphragm-bonded FBG sensor under coupled pressure–temperature loading. The experiments were conducted using a laboratory-scale pressure–temperature simulator over a pressure range of 0–2.0 MPa and a temperature range of 5–50°C, followed by combined pressure–temperature testing. The sensor’s response was found to be nonlinear. Polynomial models (quadratic or 3rd-order) consistently yielded better results than linear models. Local sensitivity varied with both pressure and temperature, ranging from 0.091 to 0.371 nm/MPa and from 0.003 to 0.022 nm/°C. Analysis using the Response Surface Method (RSM) showed that pressure contributes significantly to the slope of the sensitivity, while temperature affects the offset shift of the wavelength. Overall, the research results offer a practical method for characterizing the response of FBG sensors under controlled pressure and temperature conditions.

22 November 2022
Verified
Conference Paper
Open access
MRMaristya Rahmadiansyah
Maristya Rahmadiansyah
SASakinah Puspa Anggraeni
Sakinah Puspa Anggraeni
MFMuhammad Yusha Firdaus
Muhammad Yusha Firdaus
MDMustika Fitriana Dewi
Mustika Fitriana Dewi
SRSasono Rahardjo
Sasono Rahardjo
AHAgus M. Hatta
Agus M. Hatta
In long-haul communication, fiber optic cable plays an important role as transmission medium. The C-Band is the typical spectrum used in common optical link implementation, especially for long-range. Generally, dense wavelength division multiplexing (DWDM) uses specific wavelength spectrum based on grid stated in ITU-T G.694.1 recommendation, in which it is proposed to acquire several wavelengths to be used as the channels in the system of DWDM communication-based sensor network. In this paper, C-band DWDM channel determination method is presented. The selected DWDM channels are determined by considering lower attenuation and chromatic dispersion in the G.652.D-based fiber optic from Corning SMF-28 fiber optic technical datasheet towards entire wavelength in C-Band area, thus the optimum channels could be discovered. As conclusion, our research found the attenuation parameter has much more significant effect to Q-factor and BER values compared to the chromatic dispersion effect and the top-five most optimized channels are listed.

10 June 2026
Verified
Conference Paper
Open access
JMJean-Philippe Metaxian
Jean-Philippe Metaxian
MPMichael Purwoadi
Michael Purwoadi
SRSasono Rahardjo
Sasono Rahardjo
NRNelly F. Riama
Nelly F. Riama
IGIndra Gunawan
Indra Gunawan
FDFlorian Duret
Florian Duret
Indonesia faces a unique combination of exposure to tsunamis, with dense coastal populations, intense seismic and volcanic activity, and multiple tsunami-generation mechanisms that can threaten shorelines with very little time for reaction.BMKG which is in charge of monitoring tsunamis faces 2 limitations: First, the operational system still relies mainly on land-based seismology, coastal sea-level observations, and precomputed modelling, while the availability and operability of deep-ocean buoy observations have remained an ongoing issue. Second, the existing system was designed for tectonic earthquake-generated tsunamis and is not sufficient on its own for non-tectonic sources such as volcanic or landslide-triggered events.To address these limitations, BPPT (subsequently integrated into BRIN in 2021), initiated the planning, design, and deployment of two prototype Ocean Bottom Unit (OBU) sensors between 2020 and 2022. The deployed units integrate high-sensitivity accelerometers and static pressure sensors to enable real-time monitoring of seismic activity and tsunami wave propagation in the northern waters of Labuan Bajo, Flores.The first OBU was installed approximately 25 km offshore at a depth of 2,110 m, whereas the second unit, positioned at the terminal section of the submarine cable, was deployed approximately 55 km offshore at a depth of 4,122 m. Both installations were strategically designed to monitor seismic activity associated with the Flores Thrust, located roughly 100 km north of Flores Island. Historical earthquakes along this tectonic structure, together with the submarine landslides they triggered, generated destructive tsunamis in 1982 and 1992, resulting in significant casualties and coastal run-up heights exceeding 20 m.The deployed submarine cable system has a total length of 55 km and incorporates 12 optical fibres, providing the necessary infrastructure for integrated sensing and real-time data transmission. At the end of April 2026, we connected a Febus Optics A1 DAS interrogator to one of the fibres for a preliminary study of local and regional seismicity. Our objectives with this initial deployment are to catalogue and characterise local seismicity, locate sources, and investigate improvements in the location of local earthquakes by using a combination of land-based seismic stations and the undersea optical cable.