Patrick Clarysse

Dr. Patrick Clarysse

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2002 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TMT. Makela
T. Makela
PCPatrick Clarysse
Patrick Clarysse
OSO. Sipila
O. Sipila
NPN. Pauna
N. Pauna
QPQuoc Cuong Pham
Quoc Cuong Pham
IMI.E. Magnin
I.E. Magnin
In this paper, the current status of cardiac image registration methods is reviewed. The combination of information from multiple cardiac image modalities, such as magnetic resonance imaging, computed tomography, positron emission tomography, single-photon emission computed tomography, and ultrasound, is of increasing interest in the medical community for physiologic understanding and diagnostic purposes. Registration of cardiac images is a more complex problem than brain image registration because the heart is a nonrigid moving organ inside a moving body. Moreover, as compared to the registration of brain images, the heart exhibits much fewer accurate anatomical landmarks. In a clinical context, physicians often mentally integrate image information from different modalities. Automatic registration, based on computer programs, might, however, offer better accuracy and repeatability and save time.

3 April 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HLHerve Lombaert
Herve Lombaert
JPJean-Marc Peyrat
Jean-Marc Peyrat
PCPierre Croisille
Pierre Croisille
SRStanislas Rapacchi
Stanislas Rapacchi
LFLaurent Fanton
Laurent Fanton
NANicholas Ayache
Nicholas Ayache
Cardiac fibers, as well as their local arrangement in laminar sheets, have a complex spatial variation of their orientation that has an important role in mechanical and electrical cardiac functions. In this paper, a statistical atlas of this cardiac fiber architecture is built for the first time using human datasets. This atlas provides an average description of the human cardiac fiber architecture along with its variability within the population. In this study, the population is composed of ten healthy human hearts whose cardiac fiber architecture is imaged ex vivo with DT-MRI acquisitions. The atlas construction is based on a computational framework that minimizes user interactions and combines most recent advances in image analysis: graph cuts for segmentation, symmetric log-domain diffeomorphic demons for registration, and log-Euclidean metric for diffusion tensor processing and statistical analysis. Results show that the helix angle of the average fiber orientation is highly correlated to the transmural depth and ranges from -41° on the epicardium to +66° on the endocardium. Moreover, we find that the fiber orientation dispersion across the population (13°) is lower than for the laminar sheets (31°). This study, based on human hearts, extends previous studies on other mammals with concurring conclusions and provides a description of the cardiac fiber architecture more specific to human and better suited for clinical applications. Indeed, this statistical atlas can help to improve the computational models used for radio-frequency ablation, cardiac resynchronization therapy, surgical ventricular restoration, or diagnosis and followups of heart diseases due to fiber architecture anomalies.

17 December 2010 in Medical Physics
Verified
Journal Article
Closed access
JVJef Vandemeulebroucke
Jef Vandemeulebroucke
SRSimon Rit
Simon Rit
JKJan Kybic
Jan Kybic
PCPatrick Clarysse
Patrick Clarysse
DSDavid Sarrut
David Sarrut

22 March 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TAT. Arts
T. Arts
FPFrits W. Prinzen
Frits W. Prinzen
Tammo DelhaasTammo Delhaas
Tammo Delhaas
JMJ. R. Milles
J. R. Milles
ARAlessandro C. Rossi
Alessandro C. Rossi
PCPatrick Clarysse
Patrick Clarysse
The new SinMod method extracts motion from magnetic resonance imaging (MRI)-tagged (MRIT) image sequences. Image intensity in the environment of each pixel is modeled as a moving sine wavefront. Displacement is estimated at subpixel accuracy. Performance is compared with the harmonic-phase analysis (HARP) method, which is currently the most common method used to detect motion in MRIT images. SinMod can handle line tags, as well as speckle patterns. In artificial images (tag distance six pixels), SinMod detects displacements accurately (error < pixels). Effects of noise are suppressed effectively. Sharp transitions in motion at the boundary of an object are smeared out over a width of 0.6 tag distance. For MRIT images of the heart, SinMod appears less sensitive to artifacts, especially later in the cardiac cycle when image quality deteriorates. For each pixel, the quality of the sine-wave model in describing local image intensity is quantified objectively. If local quality is low, artifacts are avoided by averaging motion over a larger environment. Summarizing, SinMod is just as fast as HARP, but it performs better with respect to accuracy of displacement detection, noise reduction, and avoidance of artifacts.

21 September 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
TGTristan Glatard
Tristan Glatard
CLCarole Lartizien
Carole Lartizien
BGBernard Gibaud
Bernard Gibaud
RSRafael Ferreira Da Silva
Rafael Ferreira Da Silva
GFGermain Forestier
Germain Forestier
DFDenis Friboulet
Denis Friboulet
This paper presents the Virtual Imaging Platform (VIP), a platform accessible at http://vip.creatis.insa-lyon.fr to facilitate the sharing of object models and medical image simulators, and to provide access to distributed computing and storage resources. A complete overview is presented, describing the ontologies designed to share models in a common repository, the workίow template used to integrate simulators, and the tools and strategies used to exploit computing and storage resources. Simulation results obtained in four image modalities and with different models show that VIP is versatile and robust enough to support large simulations. The platform currently has 200 registered users who consumed 33 years of CPU time in 2011.

1 December 2010 in Medical Image Analysis
Verified
Journal Article
Closed access
JSJoël Schaerer
Joël Schaerer
CCChristopher Casta
Christopher Casta
JPJérôme Pousin
Jérôme Pousin
PCPatrick Clarysse
Patrick Clarysse