Domenico Suriano

Dr. Domenico Suriano

National Agency for New Technologies, Energy and Sustainable Economic Development, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Atmospheric Environment
Verified
Journal Article
Open access
CBC. Borrego
C. Borrego
ACA.M. Costa
A.M. Costa
JGJ. Ginja
J. Ginja
Marlene AmorimMarlene Amorim
Marlene Amorim
MCM. Coutinho
M. Coutinho
Michele PenzaMichele Penza
Michele Penza
The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th–27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation.The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development.The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12–0.77), CO (r2: 0.53–0.87), and NO2 (r2: 0.02–0.89). For PM (r2: 0.07–0.36) and SO2 (r2: 0.09–0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control

1 November 2018 in Atmospheric Environment
Verified
Journal Article
Closed access
CBC. Borrego
C. Borrego
JGJ. Ginja
J. Ginja
MCMiguel Coutinho
Miguel Coutinho
CRC. Ribeiro
C. Ribeiro
KKK. Karatzas
K. Karatzas
Michele PenzaMichele Penza
Michele Penza

3 April 2008 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
Michele PenzaMichele Penza
Michele Penza
PAPatrizia Aversa
Patrizia Aversa
GCGennaro Cassano
Gennaro Cassano
Domenico SurianoDomenico Suriano
Domenico Suriano
WWWojtek Wlodarski
Wojtek Wlodarski
EVEnrico Verona
Enrico Verona
A thin-film bulk acoustic resonator (TFBAR) based on a vibrating membrane of AlN/Si3N4 has been fabricated onto a silicon substrate and functionally characterized as gas sensor at a resonating frequency of 1.045 GHz. This novel TFBAR-based gas sensor has been functionalized by a sensing nanocomposite layer, prepared by a Langmuir-Blodgett (LB) technique, of single-walled carbon nanotubes (SWCNTs) embedded in a host matrix of organic material of cadmium arachidate. High-performance gas detection at room temperature of a SWCNT-coated TFBAR sensor has been reported. The sensing device exhibits high sensitivity (e.g., acetone: 12 kHz/ppm; ethylacetate: 17.3 kHz/ppm), fast response (within 2-3 min), slow reversibility (within 1 h), and good repeatability (les 5% variation) of response toward tested organic vapors of acetone, ethylacetate, and toluene.

1 November 2014
Verified
Conference Paper
Closed access
Michele PenzaMichele Penza
Michele Penza
Domenico SurianoDomenico Suriano
Domenico Suriano
MVMaria Gabriella Villani
Maria Gabriella Villani
LSLaurent Spinelle
Laurent Spinelle
MGMichel Gerboles
Michel Gerboles
This experimental study focusses on air quality monitoring by low-cost and accurate sensors to provide a rank of air quality indices for citizens community in smart cities. Inter-comparison long-term measurements of CO, NO2, SO2 and PM10 are performed in a real scenario using referenced chemical analyzers at air-quality monitoring stations. The accuracy of the low-cost sensors is assessed in order to address the Data Quality Objectives (DQO) of the EU Air Quality Directive 2008/50/EC for indicative measurements. These preliminary results show that the low-cost sensors, when accurate, are suitable to define a rank of individual air quality index (AQI) to inform effectively general public and enhance environmental awareness. Finally, we show that the developed multiparametric sensor-system NASUS can be integrated both in a distributed city-network based on cost-effective fixed nodes, and in portable handheld sensor-systems to monitor air-pollution personal exposure.

31 March 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
Domenico SurianoDomenico Suriano
Domenico Suriano
Michele PenzaMichele Penza
Michele Penza
Air pollution significantly affects public health in many countries. In particular, indoor air quality can be equally, if not more, concerning than outdoor emissions of pollutant gases. However, monitoring the air quality in homes and apartments using chemical analyzers may be not affordable for households due to their high costs and logistical issues. Therefore, a new alternative is represented by low-cost air quality monitors (AQMs) based on low-cost gas sensors (LCSs), but scientific literature reports some limitations and issues concerning the quality of the measurements performed by these devices. It is proven that AQM performance is significantly affected by the calibration model used for calibrating LCSs in outdoor environments, but similar investigations in homes or apartments are quite rare. In this work, the assessment of an AQM based on electrochemical sensors for CO, NO2, and O3 has been performed through an experiment carried out in an apartment occupied by a family of four during their everyday life. The state-of-the-art of the LCS calibration is featured by the use of multivariate linear regression (MLR), random forest regression (RF), support vector machines (SVM), and artificial neural networks (ANN). In this study, we have conducted a comparison of these calibration models by using different sets of predictors through reference measurements to investigate possible differences in AQM performance. We have found a good agreement between measurements performed by AQM and data reported by the reference in the case of CO and NO2 calibrated using MLR (R2 = 0.918 for CO, and R2 = 0.890 for NO2), RF (R2 = 0.912 for CO, and R2 = 0.697 for NO2), and ANN (R2 = 0.924 for CO, and R2 = 0.809 for NO2).

8 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
Michele PenzaMichele Penza
Michele Penza
Domenico SurianoDomenico Suriano
Domenico Suriano
VPValerio Pfister
Valerio Pfister
MPMario Prato
Mario Prato
GCGennaro Cassano
Gennaro Cassano
A sensors network based on 11 nodes (10 stationary and 1 mobile mounted on public bus) distributed in Bari (Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, port, airport) to enhance environmental awareness of the citizens and to supplement the expensive official air monitoring stations with cost-effective sensor-nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3, SO2), optical particle counter (PM1.0, PM2.5, PM10), NDIR infrared sensor (CO2), photo-ionisation detector (total VOCs), including microsensors for temperature and relative humidity. The sensors are running to assess the performance during a campaign (June 2015–December 2017) of several months for citizen science in sustainable smart cities. The air quality index (AQI) for a given pollutant has been measured and compared to the public reference environmental data. The results of the AQ monitoring long-term campaign for selected sensor-nodes are presented.