A sensors network based on 11 nodes (10 stationary and 1 mobile mounted on public bus) distributed in Bari (Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, port, airport) to enhance environmental awareness of the citizens and to supplement the expensive official air monitoring stations with cost-effective sensor-nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3, SO2), optical particle counter (PM1.0, PM2.5, PM10), NDIR infrared sensor (CO2), photo-ionisation detector (total VOCs), including microsensors for temperature and relative humidity. The sensors are running to assess the performance during a campaign (June 2015–December 2017) of several months for citizen science in sustainable smart cities. The air quality index (AQI) for a given pollutant has been measured and compared to the public reference environmental data. The results of the AQ monitoring long-term campaign for selected sensor-nodes are presented.
The accurate measurement of moisture content in pure gases and in gas mixtures, such as air, has great relevance in many industrial processes. In the present study, graphene oxide reduced through a mild alkaline treatment was used as a humidity sensing material to fabricate a flexible chemiresistive device operating at room temperature. The active layer was deposited by solution casting on a substrate of bimatted polyester, previously coated with inkjet-printed interdigitated electrodes made of silver. Structural investigations were performed by means of X-ray diffraction, Raman spectroscopy, and FTIR spectroscopy, while the optical properties were investigated using UV-VIS absorption and photoluminescence excitation spectroscopy. With increasing relative hu-midity from 0 to 80%, the electrical resistance decreased from about 1.4 GΩ to 2.5 MΩ. The ex-traordinarily large range of resistance values highlights the ultrahigh humidity sensitivity of re-duced graphene oxide, which acquires a fair amount of electrical conductivity after physisorption of water molecules but results in a highly resistive material in dry air. The high sensitivity at room temperature, the response’s repeatability, the wide relative humidity range detected, and the fast response time are the main advantages of the proposed humidity sensor, while the presence of some hysteresis, mainly at low relative humidity, and the recovery time need further improve-ment. Finally, the sensing mechanisms are briefly discussed.
The air quality in modern cities and urban areas is strongly affected by chemical pollutants such as toxic gases, volatile organic compounds, and particulate matter. They are monitored by governmental agencies using regulatory monitoring stations, which are highly accurate, but also very expensive, bulky, and maintenance demanding. There is a compulsory need to monitor air quality at high spatial–temporal resolution in smart cities for public health protection and environmental sustainability. Properly calibrated low-cost and low-accuracy sensors are usually deployed in stationary and mobile nodes for urban air quality monitoring. A simple indicator of the current status of urban air pollution is the Air Quality Index (AQI) used to communicate the pollution level under the time-changing trend of a specific pollutant. In this study, continuous measurements have been performed in the city of Bari (southern Italy) by electrochemical gas sensors (NO2, O3, CO), optical particle counters (OPC) for particulate matter (PM10), and NDIR infrared sensors (CO2), including microsensors for temperature and relative humidity. The sensors have been installed in stationary nodes located in urban sites and in a mobile node mounted on a public bus moving on urban routes. AQI data gathered by the low-cost sensors have been compared with reference instrumentations as a case study of citizen science.
A sensor network based on 10 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality (AQ) monitoring. The low-cost sensor systems have been installed in specific sites (e.g., buildings, offices, schools, streets, ports, and airports) to enhance environmental awareness of the citizens and to supplement the expensive official air-monitoring stations with cost-effective sensor nodes at high spatial and temporal resolution. Continuous measurements were performed by low-cost electrochemical gas sensors (CO, NO2, O3), optical particle counter (PM10), and NDIR infrared sensor (CO2), including micro-sensors for temperature and relative humidity. The sensors are operated to assess the performance during a campaign (July 2015–December 2017) of several months for citizen science in sustainable smart cities. Typical values of CO2, measured by distributed nodes, varied from 312 to 494 ppm (2016), and from 371 to 527 ppm (2017), depending on seasonal micro-climate change and site-specific conditions. The results of the AQ-monitoring long-term campaign for selected sensor nodes are presented with a relative error of 26.2% (PM10), 21.7% (O3), 25.5% (NO2), and 79.4% (CO). These interesting results suggest a partial compliance, excluding CO, with Data Quality Objectives (DQO) by the European Air Quality Directive (2008/50/EC) for Indicative (Informative) Measurements.
A sensors network based on 8 stationary nodes distributed in Bari (Southern Italy) has been deployed for urban air quality monitoring during advection events of Saharan dust in the period 2015–2017. The low-cost sensor-systems have been installed in specific sites (buildings, offices, schools, streets, airport) to assess the PM10 concentration at high spatial and temporal resolution in order to supplement the expensive official air monitoring stations for citizen science purposes. Continuous measurements were performed by a cost-effective optical particle counter (PM10), including temperature and relative humidity sensors. They are operated to assess the performance during a long-term campaign (July 2015–December 2017) of 30 months for smart cities applications. The sensor data quality has been evaluated by comparison to the reference data of the 9 Air Quality Monitoring Stations (AQMS), managed by local environmental agency (ARPA-Puglia) in the Bari city.
A flexible humidity sensor operating at room temperature was produced by direct drop casting of a graphene oxide (GO) water solution on a substrate of bimatted polyester, previously coated with inkjet-printed interdigitated electrodes in silver. The GO was synthesized by using a modified Hummers’ method, followed by an alkaline treatment with a water solution of KOH. Changes in the device resistance were measured for varying levels of relative humidity in the range from 15% to 70% in a sealed stainless cell. The device showed high sensitivity, good repeatability, and fast recovery time. Being flexible and robust, the proposed sensors could be easily integrated into wearable equipment.