Jakub Jan Słowiński

Dr. Jakub Jan Słowiński

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Dariusz PykaDariusz Pyka
Dariusz Pyka
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
AKAdam Kurzawa
Adam Kurzawa
MRMaciej Robert Roszak
Maciej Robert Roszak
MSMateusz Stachowicz
Mateusz Stachowicz
DGDominika Grygier
Dominika Grygier
This study investigates the mechanical properties and biocompatibility of eight commercially available filaments tailored for Fused Deposition Modeling (FDM) additive manufacturing. Test specimens were fabricated using original PRUSA MK4 printers, with ten samples from each selected polymer. Mechanical evaluations through static tensile and three-point bending tests revealed that PETG Carbon and PA+15CF exhibited superior tensile and flexural strengths, making them highly suitable for applications requiring high mechanical resilience. Biocompatibility assessments in line with the ISO 10993-5:2009 and ISO 10993-12:2021 standards indicated that all materials except FiberFlex 40D Fiberlogy were non-cytotoxic, supporting their potential in biomedical applications. The experimental data established material constants within the Johnson–Cook strength model, which effectively predicted the mechanical behaviors of monotonic materials like FiberFlex 40D, PETG, HIPS, TPU, and PA+15CF Rosa 3D, with maximum fitting errors not exceeding 2.6%. However, the model was inadequate for non-monotonic materials like PLA and PETG, resulting in higher errors and less accurate simulations. Scanning electron microscope (SEM) analyses provided insights into fracture mechanisms, correlating fracture surface characteristics with mechanical performance. This comprehensive study advances the understanding of mechanical properties in thermoplastic materials for 3D printing, validates numerical models for certain materials, and confirms material suitability for biomedical use.

10 April 2025 in Polymers
Verified
Journal Article
Open access
PDF file
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
MRMaciej Robert Roszak
Maciej Robert Roszak
MKMikołaj Kazimierczak
Mikołaj Kazimierczak
GSGrzegorz Skrzypczak
Grzegorz Skrzypczak
MSMaksymilian Stępczak
Maksymilian Stępczak
Fused deposition modelling (FDM) technology provides a flexible and cost-effective solution for the manufacture of polymer components, enabling the precise design of structures and the incorporation of a variety of composite materials. Its development is confirmed by numerous studies on fibre reinforcements (e.g., GFRP and CF) and thermosetting resin modifications, resulting in improved impact strength and fracture toughness and increased thermal stability of products. The final mechanical properties are significantly influenced by processing parameters (e.g., fill density, layer height, and printing speed) and internal geometry (e.g., lattice structures), which can be further optimised by numerical analyses using constitutive models such as the Johnson–Cook model. The focus of the study presented here is on the fabrication of composites from FDM dies filled with F8 polyurethane resin. Filaments, including PETG carbon and PETG, were tested for potential applications with the resin. A static compression test, supported by numerical analysis using the Johnson–Cook model, was carried out to identify key mechanical characteristics and to predict the material’s behaviour under different loading conditions. The results indicate that these structures exhibit numerous potential delamination planes and voids between filament paths, leading to relatively low maximum stress values (σm ≈ 2.5–3 MPa). However, the impregnation with polyurethane resin significantly enhances these properties by bonding the layers and filling the pores, resulting in a more homogeneous and stronger composite. Additionally, numerical simulations effectively captured key aspects of structural behaviour, identifying critical stress concentration areas, particularly along the side walls and in regions forming triangular stress zones. These findings provide valuable insights into the potential of resin-filled FDM structures in engineering applications, demonstrating their improved performance over purely printed samples.

6 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
MRMaciej Robert Roszak
Maciej Robert Roszak
KKKarina Krawiec
Karina Krawiec
RHRadomir Henklewski
Radomir Henklewski
Krzysztof JamroziakKrzysztof Jamroziak
Krzysztof Jamroziak
Horses have been companions of people for thousands of years. Areas in which humans use these animals include, for example, transport, participation in sports competitions, or during rehabilitation (hippotherapy). Unfortunately, injuries such as lower limb fracture very often require euthanasia due to the significant difficulties in conducting fracture therapy/repair. Therefore, there are still many possibilities for the improvement of existing treatments. The aim of the study was to conduct a numerical analysis enabling the prediction of bone union of the third metacarpal bone of a horse. The loading conditions and type of fracture were based on a pony weighing 120 kg; however, research on a live animal was not the purpose of this study. Numerical studies were carried out for three different methods of stabilization using bone plates in the Ansys program (lateral, anterior, and lateral–anterior stabilization). An algorithm based on the Carter model was used to predict bone union, while linear-coupled models were used to describe the behaviour of materials. The authors also performed dynamic analyses in the Abaqus/Explicit program to determine the maximum speed at which the horse could move so that the fracture would not deepen. For dynamic analyses, the authors used nonlinear models—Johnson–Cook in the case of the 316L surgical steel material and cortical bone. Material failure was described using the Johnson–Cook failure model for steel and the limit strain model for cortical bone. A series of numerical simulations allowed to determine the direction of bone union building, and the most favourable case of stabilization was determined.

Verified
Journal Article
Open access
PDF file
KKKarina Krawiec
Karina Krawiec
AKAdam Kurzawa
Adam Kurzawa
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
RFRomulus Calin Fodor
Romulus Calin Fodor
ŁPŁukasz Pałka
Łukasz Pałka
The mechanical properties of dental implants are critical for their durability. The purpose of this study was to determine the maximum force required to induce full pull-out of a titanium implant from the bone and to characterize the mechanical behavior during this process. First, pull-out tests were performed on monolithic implants embedded in bovine ribs and foam blocks that mimic the mechanical parameters of human bone, allowing a quantitative evaluation of implant–bone interface strength and a comparison of geometric variants. Second, the extraction process was recreated in a three dimensional finite element model incorporating nonlinear interface contact and parameterization, enabling the reproduction of load–displacement curves; the results obtained showed good agreement with the experiment. Third, the fracture surfaces were observed macroscopically and by scanning electron microscopy/energy dispersive spectroscopy. The results demonstrated significant distinctions in the forces required to extract implants with varying thread geometries, clearly indicating the impact of implant design on their mechanical stability. The presented FEM-based methodology provides a reliable tool to study mechanical interactions at the implant–bone interface. The findings obtained can improve our understanding of implant behavior in biological systems and provide a basis for further optimization of their design.

1 October 2016 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
ACAleksandra Czarnecka
Aleksandra Czarnecka

8 January 2018 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
Jakub Jan SłowińskiJakub Jan Słowiński
Jakub Jan Słowiński
KKKonrad Kudłacik
Konrad Kudłacik
Introduction. The treatment of femoral diaphyseal fractures by intramedullary nailing has become a common procedure in orthopaedic surgery. The purpose of this numerical simulation was to present how the changes in configuration of the stabilisation system can affect the stress and displacement state in the bone tissue and implanted device.Material and Methods. The numerical comparison of the stabilisation variants for the type 32-A2 femoral diaphyseal fracture (according to the AO classification) performed by using the Charfix2 (ChM®) anatomical nail locked in a number of chosen ways. The displacement and the stress distributions both in the bone and implant were obtained and analysed by computational simulation.Results. In all models, there was the same characteristic distribution, which shows there were minimal rotational movements of the bone around the anatomical axis. In all cases, stress concentrations were generated in the nail material in the area of the fracture gap.Conclusions. The obtained results indicate that there is a visible advantage to one-plane distal stabilisation in the reduction of stresses regardless of the type of proximal stabilisation. The results of calculations indicate that the use of proximal stabilisation with a neck screw reduces the possibility of damage to the implant.