Janosch Kunczik

Dr. Janosch Kunczik

RWTH Aachen University, Faculty of Medicine, Aachen, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
Janosch KunczikJanosch Kunczik
Janosch Kunczik
LZLeonie Zieglowski
Leonie Zieglowski
RTRené Tolba
René Tolba
AAAhmed Abdelrahman
Ahmed Abdelrahman
MCMichael Czaplik
Michael Czaplik
Animal research has always played a crucial role in various medical and scientific breakthroughs. They offer, inter alia, insights into diseases mechanisms, genetic predisposition to a disease, and drug therapy. However, the use of animals for medical research is a cause of major controversies and debates in modern science. To warrant high bioethical standards, new directives have been being adopted to replace animal research whenever possible, to reduce the number of animals, and to refine the procedures to minimize stress and pain. Here, we present two new approaches, based on thermal imaging (a remote and passive technology), to assess respiratory rate (RR) as well as exploratory behavior and general activity in rodents. In animal research, these parameters are gold standards for welfare assessment. The approaches were validated in a study conducted with both rats and mice. To test the feasibility of our algorithm to estimate RR, thermal videos from anesthetized rodents were acquired. The capability of the second approach to monitor activity was tested with videos of Open Field tests. Regarding RR, a high agreement between thermal imaging and gold standard (electrocardiography-derived RR) was achieved. The mean relative error averaged 0.50 ± 0.15 breaths/min and 4.55 ± 2.94 breaths/min for rats and mice, respectively. The second approach was capable of monitoring and tracking the activity of the rodents very well. This paper demonstrates that thermal imaging is a promising and relevant alternative for monitoring of RR and activity in rodents, thus contributing to the remote assessment of animal welfare.

16 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Janosch KunczikJanosch Kunczik
Janosch Kunczik
KHKerstin Hubbermann
Kerstin Hubbermann
Lucas MöschLucas Mösch
Lucas Mösch
AFAndreas Follmann
Andreas Follmann
MCMichael Czaplik
Michael Czaplik
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
The ability to continuously and unobtrusively monitor and classify breathing patterns can be very valuable for automated health assessments because respiration is tightly coupled to many physiological processes. Pathophysiological changes in these processes often manifest in altered breathing patterns and can thus be immediately detected. In order to develop a breathing pattern monitoring system, a study was conducted in which volunteer subjects were asked to breathe according to a predefined breathing protocol containing multiple breathing patterns while being recorded with color and thermal cameras. The recordings were used to develop and compare several respiratory signal extraction algorithms. An algorithm for the robust extraction of multiple respiratory features was developed and evaluated, capable of differentiating a wide range of respiratory patterns. These features were used to train a one vs. one multiclass support vector machine, which can distinguish between breathing patterns with an accuracy of 95.79 %. The recorded dataset was published to enable further improvement of contactless breathing pattern classification, especially for complex breathing patterns.

5 August 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
Janosch KunczikJanosch Kunczik
Janosch Kunczik
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
LZLeonie Zieglowski
Leonie Zieglowski
RTRené Tolba
René Tolba
LWLaura Wassermann
Laura Wassermann
MCMichael Czaplik
Michael Czaplik
Laboratory animal research was always crucial for scientific breakthroughs in the fields of medicine and biology. Animal trials offer insights into various disease mechanisms, genetics, drug therapy and the effect of different external factors onto living organisms. However, conducting animal trials is highly controversial. To ensure high ethical standards, a number of directives have been adopted in the European Union, which seek to replace, reduce and refine animal trials. Hence, severity assessment plays an important role in today's laboratory animal research. Currently, severity of trials is assessed by highly rater dependent scoring systems. In this paper, we propose a method for unobtrusive, automated and contactless measurement of respiratory rate (RR) and heart rate (HR). We were able to extract RR and HR with an high agreement between our method and a contact-based reference method. The Root Mean Squared Error (RMSE) averaged 0.32 ± 0.11 breaths/min for RR and 1.28 ± 0.62 beats/min for HR in rats, respectively. In mice, the RMSE averaged 1.42 ± 0.97 breaths/min for RR and 1.36 ± 0.87 beats/min, respectively. In the future, these parameters can be used for new, objective scoring systems, which are not susceptible to inter-rater variability.

8 July 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
Janosch KunczikJanosch Kunczik
Janosch Kunczik
ABAndré Bleich
André Bleich
CHChristine Haeger
Christine Haeger
Fabian KiesslingFabian Kiessling
Fabian Kiessling
MCMichael Czaplik
Michael Czaplik
Animal studies have made a great contribution to medical advancement and play a vital role in current scientific work, as they replicate key aspects of human physiological and pathophysiological processes.1,2 They allow a higher understanding of various disease mechanisms as well as of genetic predisposition to certain diseases. Furthermore, they have been improving medication and treatments, allowing for a higher quality of life for people all over the world.3 In 2011, nearly 11.5 million animals were used for scientific purposes in the EU, of which 76.8% were rodents (including mice, rats, guinea-pigs, and hamsters), whereas only 0.67% were pigs, 0.25% were sheep, and 0.05% were primates.4 The remaining 22.23% correspond to other animal species (including birds, reptiles, and amphibians).4

7 June 2023 in Animals
Verified
Journal Article
Open access
PDF file
LBLukas Breuer
Lukas Breuer
Lucas MöschLucas Mösch
Lucas Mösch
Janosch KunczikJanosch Kunczik
Janosch Kunczik
VBVerena Buchecker
Verena Buchecker
HPHeidrun Potschka
Heidrun Potschka
Carina Barbosa PereiraCarina Barbosa Pereira
Carina Barbosa Pereira
Animal research has always been crucial for various medical and scientific breakthroughs, providing information on disease mechanisms, genetic predisposition to diseases, and pharmacological treatment. However, the use of animals in medical research is a source of great controversy and ongoing debate in modern science. To ensure a high level of bioethics, new guidelines have been adopted by the EU, implementing the 3R principles to replace animal testing wherever possible, reduce the number of animals per experiment, and refine procedures to minimize stress and pain. Supporting these guidelines, this article proposes an improved approach for unobtrusive, continuous, and automated monitoring of the respiratory rate of laboratory rats. It uses the cyclical expansion and contraction of the rats’ thorax/abdominal region to determine this physiological parameter. In contrast to previous work, the focus is on unconstrained animals, which requires the algorithms to be especially robust to motion artifacts. To test the feasibility of the proposed approach, video material of multiple rats was recorded and evaluated. High agreement was obtained between RGB imaging and the reference method (respiratory rate derived from electrocardiography), which was reflected in a relative error of 5.46%. The current work shows that camera-based technologies are promising and relevant alternatives for monitoring the respiratory rate of unconstrained rats, contributing to the development of new alternatives for a continuous and objective assessment of animal welfare, and hereby guiding the way to modern and bioethical research.

Verified
Journal Article
Open access
PDF file
LELisa Ernst
Lisa Ernst
Zoltan CziganyZoltan Czigany
Zoltan Czigany
PPPascal Paschenda
Pascal Paschenda
MSMareike Schulz
Mareike Schulz
LBLukas Breuer
Lukas Breuer
RTRené Tolba
René Tolba
Ischemia-reperfusion injury remains a fundamental problem during organ transplantation logistics. One key technical factor is the rapid allograft rewarming during the time of vascular reconstruction in the recipient. In this pilot study, a new thermal insulation bag (TIB) for organ transplantation was used. Insulation capacity, tissue compatibility, and usability were tested initially ex vivo on porcine kidneys (n = 24) followed by the first in vivo usage. Fourteen female German landrace pigs underwent kidney auto-transplantation after 24 h cold storage (4 °C). During the implantation process the kidney was either insulated with the new TIB, or it was not thermo-protected at all, which represents the clinical standard. In this proof-of-concept study, the usability (knife-to-skin-time) and the general thermal capacity (30 min warm storage at 38 °C ex vivo p < 0.001) was shown. The clinical outcome showed significant differences in the determination of CRP and pi-GST levels. Syndecan-1 Antibody staining showed clear significant higher counts in the control group (p < 0.01) indicating epithelial damage. However, the effect on renal outcomes in not severely pre-damaged kidneys does not appear to be conclusively significant. A close follow-up study is warranted, especially in the context of marginal organs or in cases where anastomosis-times are prolonged due to surgical complexity (e.g., multiple vessels and complex reconstructions).