Concrete is widely utilized across various industries as a containment material. One essential property related to its performance is permeability, which determines its ability to allow the passage of gases or liquids through its pores and capillaries and even the transmission of aggressive agents. This study focused on investigating the permeability of gases with varying atomic weights and molecular volumes, such as helium, nitrogen, oxygen, and argon, to pass through concrete. The primary objective was to determine the significance of variation in permeability and to evaluate and differentiate their behavior. To achieve this, concrete test specimens were employed, and factors such as cold joint impact, gas pressure, and specimen saturation levels were considered. Throughout the study, changes in weight, specimen humidity, resistivity, and ultrasonic pulse velocity were monitored. The findings suggested that within concrete, the variation in permeability for these gases is negligible. By utilizing the acquired data, the present study estimated the permeability of hydrogen through mathematical models based on gas pressure and concrete thickness. These insights contribute to a deeper comprehension of concrete gas permeability and its potential impact on improving hydrogen containment.
Steel fibers (SF) and polyolefin (PF) are widely used for shotcrete, especially in tunnelling. Both SF and PF and have shown to meet the standards in order to reduce or substitute the conventional steel mesh as reinforcement of concrete showing mechanical and productive advantages. This study sought the analysis and assessment of the mechanical properties of fiber reinforced shotcrete, comparing in-situ with laboratory results. This was performed with low and high fiber dosages of SF and PF as well as a combination of them (hybrid mixtures). A total of seven mixtures, two of steel, two of polyolefins, two hybrids and a control mixture were manufactured at laboratory and in situ. By performing tests according to EN 14651 and slabs according to EN 14488-5, it was possible to characterize the residual flexural strengths (fRj), and energy absorption capacity (E25mm) in slabs. In addition, a fracture surface analysis was performed, and the orientation factor was obtained. This allowed the authors to quantify the loss of residual strength on site and correlate it with the fiber content and positioning. Moreover, some relationships between beam and slab tests were found, allowing to correlate the most relevant type of tests in the field of fiber reinforced concrete.