Koushik Guha

Dr. Koushik Guha

National Institute of Technology Silchar
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
Zoran JaksicZoran Jaksic
Zoran Jaksic
SDSwagata Devi
Swagata Devi
Olga JakšićOlga Jakšić
Olga Jakšić
KGKoushik Guha
Koushik Guha
The application of artificial intelligence in everyday life is becoming all-pervasive and unavoidable. Within that vast field, a special place belongs to biomimetic/bio-inspired algorithms for multiparameter optimization, which find their use in a large number of areas. Novel methods and advances are being published at an accelerated pace. Because of that, in spite of the fact that there are a lot of surveys and reviews in the field, they quickly become dated. Thus, it is of importance to keep pace with the current developments. In this review, we first consider a possible classification of bio-inspired multiparameter optimization methods because papers dedicated to that area are relatively scarce and often contradictory. We proceed by describing in some detail some more prominent approaches, as well as those most recently published. Finally, we consider the use of biomimetic algorithms in two related wide fields, namely microelectronics (including circuit design optimization) and nanophotonics (including inverse design of structures such as photonic crystals, nanoplasmonic configurations and metamaterials). We attempted to keep this broad survey self-contained so it can be of use not only to scholars in the related fields, but also to all those interested in the latest developments in this attractive area.

10 October 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SBSamuyelu Bommu
Samuyelu Bommu
Aravind Kumar MadamAravind Kumar Madam
Aravind Kumar Madam
KBKiranmai Babburu
Kiranmai Babburu
NSNANDOORI SRIKANTH
NANDOORI SRIKANTH
LTLakshmi Narayana Thalluri
Lakshmi Narayana Thalluri
SSS. Kiran S
S. Kiran S

1 December 2015 in Solid-State Electronics
Verified
Journal Article
Closed access
KGKoushik Guha
Koushik Guha
MKMithlesh Kumar
Mithlesh Kumar
SASaurabh Agarwal
Saurabh Agarwal
SBSrimanta Baishya
Srimanta Baishya

1 June 2018 in Micro & Nano Letters
Verified
Journal Article
Open access
PDF file
RMReshmi Maity
Reshmi Maity
NMNiladri Maity
Niladri Maity
KGKoushik Guha
Koushik Guha
SBSrimanta Baishya
Srimanta Baishya
The work analyses the significance of fringing capacitance in modelling effectively the amplitude of the ultrasonic waves generated by silicon nitride membrane‐based micromachined ultrasonic transducer (MUT). The amplitude of the ultrasonic waves is proportional to the displacement of the biased membrane under the influence of a sinusoidal signal. Fringing capacitance is significant as for operating the transducer in the medical imaging regime of frequency range 1–10 MHz, the dimension of the electrodes of the MUT capacitor becomes comparable with the separation between them. The device is modelled first without the fringing effect and then Palmer, Landau's and Younes Ataiiyan's approaches are considered for evaluating the fringing capacitance. The device is finite element method analysed by PZFLEX 3D simulator. The membrane displacement is evaluated with variation in device structural parameters of membrane radius and thickness, electrode separation and bias voltage for an extensive range of values. Fractional percentage error of the above analytical approaches is evaluated with respect to the PZFLEX which are regarded as closest to reality. Substantial decrease in the error is observed on modelling the device with the effect of the fringing capacitance.

22 May 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SCSagarika Choudhury
Sagarika Choudhury
KBKrishna Lal Baishnab
Krishna Lal Baishnab
KGKoushik Guha
Koushik Guha
Zoran JaksicZoran Jaksic
Zoran Jaksic
Olga JakšićOlga Jakšić
Olga Jakšić
Jacopo IANNACCIJacopo IANNACCI
Jacopo IANNACCI
This study discusses the use of a triple material gate (TMG) junctionless tunnel field-effect transistor (JLTFET) as a biosensor to identify different protein molecules. Among the plethora of existing types of biosensors, FET/TFET-based devices are fully compatible with conventional integrated circuits. JLTFETs are preferred over TFETs and JLFETs because of their ease of fabrication and superior biosensing performance. Biomolecules are trapped by cavities etched across the gates. An analytical mathematical model of a TMG asymmetrical hetero-dielectric JLTFET biosensor is derived here for the first time. The TCAD simulator is used to examine the performance of a dielectrically modulated label-free biosensor. The voltage and current sensitivity of the device and the effects of the cavity size, bioanalyte electric charge, fill factor, and location on the performance of the biosensor are also investigated. The relative current sensitivity of the biosensor is found to be about 1013. Besides showing an enhanced sensitivity compared with other FET- and TFET-based biosensors, the device proves itself convenient for low-power applications, thus opening up numerous directions for future research and applications.

14 May 2015 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
KGKoushik Guha
Koushik Guha
MKMithlesh Kumar
Mithlesh Kumar
APAjay Parmar
Ajay Parmar
SBSrimanta Baishya
Srimanta Baishya