Lara Franchin

Ms. Lara Franchin

Department of Information Engineering, University of Padua, Padua, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Open access
Stefano BonaldoStefano Bonaldo
Stefano Bonaldo
LFLara Franchin
Lara Franchin
EPElisabetta Pasqualotto
Elisabetta Pasqualotto
ECErica Cretaio
Erica Cretaio
CLCarmen Losasso
Carmen Losasso
Alessandro PaccagnellaAlessandro Paccagnella
Alessandro Paccagnella
The bovine serum albumin (BSA) protein is employed in genosensors as non-specific binding blocker. In this work, the influence of BSA on the electrochemical response of an DNA-based biosensor is explored by electrochemical impedance spectroscopy and double pulse voltammetry technique. Each buffer component of the hybridization buffer is studied on bare gold electrodes and on ssDNA-functionalized electrodes. The BSA is found to have the higher influence on the sensor sensitivity. The superficial modification induced by BSA greatly affects the electrochemical signal due to steric hindrance, which decreases the device sensitivity. Thus, we propose a novel treatment method of the BSA by using the proteinase K. The proteinase K reduces the steric hindrance, improving the charge transfer at the electrode/solution interface and enhancing the genosensor sensitivity. The proposed method is based on a rapid BSA treatment. The BSA solution containing the proteinase K is kept for one hour at 37 °C to obtain BSA fragmentation and then, heated up to 95 °C for 2 minutes to inactive the enzyme and denature the fragments. The method was tested successfully on a genosensor for the detection of the Campylobacter Jejuni . Double pulse current measurements clearly discriminate the presence of complementary DNA fragments with any other non-complementary DNA fragments.

26 June 2025 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
MPM. Ploner
M. Ploner
BSBajramshahe Shkodra
Bajramshahe Shkodra
LFLara Franchin
Lara Franchin
AAA. Altana
A. Altana
Mattia PetrelliMattia Petrelli
Mattia Petrelli
LPLuisa Petti
Luisa Petti
Cytokines play a vital role in immune system signaling, making their detection crucial for continuous health monitoring. Among the various cytokines, tumor necrosis factor-alpha (TNF-α) stands out as a key regulator of the immune response. Notably, TNF-α can be detected in sweat at concentrations as low as pg/mL, with levels strongly correlated with those in blood. Despite its importance, sensitive, wearable, and continuous monitoring of TNF-α in sweat remains limited. To address this gap, this study presents a flexible electrochemical sensor integrated into a microfluidic system for the sensitive and selective detection of TNF-α under continuous sweat flow. First, we present the fabrication of two distinct, miniaturized designs of flexible screen-printed carbon three-electrode platforms, which are subsequently biofunctionalized with gold nanoparticles (AuNPs) coated with TNF-α-specific thiolated aptamers. Next, we compare the two geometrically distinct AuNP-aptamer-functionalized sensors, utilizing experimental and novel simulation-based characterization techniques. Finally, the sensors are integrated into a custom-built microfluidic system enabling the detection of TNF-α ranging from 0.2 to 1000 pg/mL under constant artificial sweat flow conditions, exhibiting high selectivity with negligible responses to non-specific analytes. These findings highlight the feasibility of integrating wearable cytokine sensors for detecting TNF-α under continuous sweat flow conditions, achieving clinically relevant sensitivity within the pg/mL range.

28 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LFLara Franchin
Lara Franchin
Stefano BonaldoStefano Bonaldo
Stefano Bonaldo
In this work, we present a multiphysics modeling approach capable of simulating electrochemical impedance spectroscopy (EIS) responses of screen-printed electrodes (SPEs) modified with self-assembled monolayers of 11-Mercaptoundecanoic acid (MUA). Commercially available gold SPEs are electrochemically characterized through experimental cyclic voltammetry and EIS measurements with 10 mM [Fe(CN)6]3−/4− redox couple in phosphate buffered saline before and after the surface immobilization of MUA at different concentrations. We design the multiphysics model through COMSOL Multiphysics® based on the 3D geometry of the devices under test. The model includes four different physics considering the metal/solution interface electrochemical phenomena, the ion and electron potentials and currents, and the measurement set-up. The model is calibrated through a set of experimental measurements, allowing the tuning of the parameters used by the model. We use the calibrated model to simulate the EIS response of MUA-modified SPEs, comparing the results with experimental data. The simulations fit the experimental curves well, following the variation of MUA concentration on the surface from 1 µM to 100 µM. The EIS parameters, retrieved through a CPE-modified Randles’ circuit, confirm the consistency with the experimental data. Notably, the simulated surface coverage estimates and the variation of charge transfer resistance due to MUA-immobilization are well matched with their experimental counterparts, reporting only a 2% difference and being consistent with the experimental electrochemical behavior of the SPEs.

8 February 2023 in IEEE Sensors Journal
Verified
Journal Article
Open access
Stefano BonaldoStefano Bonaldo
Stefano Bonaldo
ECErica Cretaio
Erica Cretaio
EPElisabetta Pasqualotto
Elisabetta Pasqualotto
MSMatteo Scaramuzza
Matteo Scaramuzza
LFLara Franchin
Lara Franchin
Alessandro PaccagnellaAlessandro Paccagnella
Alessandro Paccagnella
In the dairy industry, the spreading of phages of Lactococcus lactis prevent the proper lactic fermentation, causing waste of contaminated products and economic losses. This work presents a cheap biosensing method for rapidly detecting the L.lactis phages. The detection is based on live L. lactis bacteria covering the sensor electrodes, whose electrical response is measured by electrochemical impedance spectroscopy (EIS). Solutions contaminated by phages induce bacteria lysis, clearly reducing the bacteria coverage over the electrodes and leading to evident parametrical shifts in the charge transfer resistance and in the impedance phase at 400 Hz. Experimental tests with laboratory contaminated samples confirm that screen-printed sensors with gold and detection capability compared to interdigitated gold electrodes. Two measurement protocols, called spill-out and drop-in methods, are evaluated to optimize the sensor detection capability and time. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed detection method with 10 7 PFU/mL phages and with a detection time of about 5 hours. Lastly, the proposed method is tested successfully with milk-based solutions. Evident shifts are measured in the charge transfer resistance of more than one order of magnitude and impedance phase differences of 43° in phages contaminated sensors.

21 November 2023 in IEEE Sensors Journal
Verified
Journal Article
Open access
Stefano BonaldoStefano Bonaldo
Stefano Bonaldo
LFLara Franchin
Lara Franchin
ECErica Cretaio
Erica Cretaio
EPElisabetta Pasqualotto
Elisabetta Pasqualotto
MSMatteo Scaramuzza
Matteo Scaramuzza
Alessandro PaccagnellaAlessandro Paccagnella
Alessandro Paccagnella
Lactococcus lactis bacteriophage infections in milk prevent the proper lactic fermentation, leading to the production of unsaleable low-quality products and great economic losses in the dairy industry. In this work, we present an innovative biosensing approach for the cost-effective detection of L. lactis phages in milk-based samples through electrochemical impedance spectroscopy (EIS). The detection is based on the evident parametric shifts in the charge transfer resistance and in the impedance phase at 100 Hz caused by different bacteria proliferation due to phage activity. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed method. Preliminary experimental tests with filtered milk-based samples confirm the sensor capability to detect phages at different concentrations in milk-based solutions in less than 4 hours. In order to reach a higher sensitivity, we propose a new milk pre-treatment adding calcium chloride (CaCl 2 ) to the samples. The EIS results with CaCl 2 -treated milk evidence an enhanced phage activity, which leads to a much larger parametric shift. Lastly, the sensor is tested with CaCl 2 -treated milk-based samples at different phages concentrations, obtaining an enhanced performance reaching the limit of detection of 10 3 PFU/mL.

25 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
EPElisabetta Pasqualotto
Elisabetta Pasqualotto
ECerica cretaio
erica cretaio
MSMatteo Scaramuzza
Matteo Scaramuzza
ATAlessandro De Toni
Alessandro De Toni
LFLara Franchin
Lara Franchin
Stefano BonaldoStefano Bonaldo
Stefano Bonaldo
The blood ammonia (NH3) level is one of the most important hepatic biomarkers for the diagnosis and monitoring of liver pathologies and infections. In this work, we developed an optimized optical biosensing method to extract and quantify the ammonia contained in complex-matrix samples emulating the blood serum. First, the approach was tested with solutions of phosphate-buffered saline (PBS) and ammonia chloride. Then, further trials were carried out with solutions of fetal bovine serum (FBS). The ammonia was extracted from the tested samples through a customized cell, and it was optically quantified by exploiting the indophenol reaction. The extraction cell included a cation-exchange membrane in Nafion, which was chemically pre-treated through cleaning procedures of sulfuric acid and hydrogen peroxide to keep a basic pH in the ammonia solution and to avoid contaminants in the membrane. From the NH3 solution, the indophenol reaction produced light-reactive indophenol dye molecules, which were used as colorimetric indicators. Through absorbance measurements of the indophenol dye solution at 670 nm wavelength, we were able to detect and quantify the ammonia level in the samples both with a spectrophotometer and a customized miniaturized read-out system, obtaining a detection limit of 0.029 µmol/mL.