ŁUKASZ SEMKŁO

Dr. ŁUKASZ SEMKŁO

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Journal of Ecological Engineering
Verified
Journal Article
Open access
Bartosz CiupekBartosz Ciupek
Bartosz Ciupek
ŁBŁukasz Brodzik
Łukasz Brodzik
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
WPWojciech Prokopowicz
Wojciech Prokopowicz
PSPiotr W. Sielicki
Piotr W. Sielicki
The aim of the research was to determine the possibility of co-combustion of conventional aviation fuel (JET A-1 jet fuel) with hydrogen (H2). The tested miniature turbojet engine was adapted to co-combust of both fuels. The results obtained from the research provide a positive premise for the...

2 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
MBMarcin Bilski
Marcin Bilski
PGPrzemysław Górnaś
Przemysław Górnaś
APAndrzej Pożarycki
Andrzej Pożarycki
PSPrzemysław Skrzypczak
Przemysław Skrzypczak
MSMieczysław Słowik
Mieczysław Słowik
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
The thermal properties of pavement layers made of concrete with varying bulk densities are a particularly interesting topic in the context of development road technologies. If a hybrid layer system is used as a starting point, with thin asphalt layers (from 1 cm to 4 cm) laid on top of a foam concrete layer, thermal properties begin to play a crucial role. The main research problem was to create a test method enabling the assessment of the influence of solar heating on the thermal parameters of the building material, especially cement concrete. For this reason, this paper is concerned specifically with the assessment of a new methodology for testing and calculating the value of the thermal diffusivity coefficient of samples made of concrete varying bulk densities. In this case, using the proprietary concept the authors built a solar simulator using a multi-source lighting system. The analysis of the results of laboratory tests and numerical analyses allowed the authors to observe that there is a strong correlation between the bulk density of samples heated and the thermal diffusivity parameter, which appears in the unidirectional heat transfer equation. The strength of this relationship has been expressed with the coefficient of determination and amounts to 99%. The calculated values of the coefficient of thermal diffusivity for samples made of foam concrete range from 0.16×10−6m2s to 0.52×10−6m2s and are lower (from 2.5 to 8 times) than the value determined for samples made of typical cement concrete.

9 April 2020 in Agronomy
Verified
Journal Article
Open access
PDF file
Łukasz GierzŁukasz Gierz
Łukasz Gierz
Krzysztof PrzybyłKrzysztof Przybył
Krzysztof Przybył
Krzysztof KoszelaKrzysztof Koszela
Krzysztof Koszela
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
SKSebastian Kwiecień
Sebastian Kwiecień
It is important to protect potatoes from insects and diseases at an early stage of their development. Pesticides are necessary to prevent loss caused by Colorado potato beetles feeding on potato leaves. Nowadays, there are attempts to reduce the use of chemical agents to the minimum necessary level. This article describes the construction of a novel valve that applies chemicals in an intermittent stream during potato treatment. Thus, it is possible to reduce the emission of chemicals to the natural environment. The article also describes the research site where the valve was tested, provides the results of laboratory investigations on different types of sprayer nozzles and their validation. Apart from that, the degree of the seed potato surface covering with the dressing was assessed in order to select the right sprayer nozzle and working pressure. The results of field tests of the seed dresser prototype with novel nozzles showed that they effectively dressed seed potatoes while saving 2 L (50%) of the chemical per hectare. Fissure sprayers achieved the highest degree of covering (up to 78%) with the first version of the valve (without auxiliary airflow). When the innovative valve (the second solution with auxiliary airstream) was applied at a distance of 50 mm from the seed potato fall path S, the highest degree of coverage with the dressing substance (up to 88%) was observed for the ejector sprayer. When the distance between the valve and the seed potato fall, path S was increased from 50 to 100 mm, the degree of surface coverage was lower for both of the valves used in the tests.

1 January 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
ŁGŁ Gierz
Ł Gierz
The demand for agricultural products increases with limited access to agricultural land. As a result, there is an increase in yield owing to new techniques applied to agriculture, i.e. precise seed potatoes treatment. For this purpose, the dressing of seed potatoes was tested using the author’s method of checking the quality of spraying with dressing agent and improving seed coverage. In the hereby work, the method of image analysis was used to detect the movement of particles of working liquid. The article presents a test stand for measuring spraying time after exiting an innovative pressure-pneumatic valve using image analysis. The analysis was made using a fast Cronos 1.4 camera. The subject of the research was the construction of the station and evaluation of the work of the innovative pressure-pneumatic valve in two configurations: without the addition of compressed air and using additional compressed air.

27 November 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
Łukasz GierzŁukasz Gierz
Łukasz Gierz
Numerical analysis of parts of the installation for transporting the mixture. The mixture consists of sand, stones and water. The analysis concerns the possibility of reducing the flow velocity of the mixture in the installation by means of installing the blades. The article presents an analysis of 10 blades that have been simulated. Speed distributions are presented after passing through the blades and determined which slows the speed of the mixture to the best possible extent.

11 February 2026 in Energies
Verified
Journal Article
Open access
PDF file
ŁBŁukasz Brodzik
Łukasz Brodzik
Bartosz CiupekBartosz Ciupek
Bartosz Ciupek
Grigore CicanGrigore Cican
Grigore Cican
ŁSŁUKASZ SEMKŁO
ŁUKASZ SEMKŁO
DSDominik Schroeder
Dominik Schroeder
Research related to the use of hydrogen is crucial because it can be a significant factor in reducing exhaust emissions into the environment. This work represents the second stage of research related to the analysis of exhaust gases from a miniature GTM 400 MOD turbojet engine. Based on the parameters obtained in the experiment, a numerical study of the flow downstream of the exhaust nozzle was performed in ANSYS software (version R1, 2025). The main goal of the calculations was to obtain the temperature distribution and compare the values at checkpoints where actual measurements were taken. The study was conducted in two stages. In the first stage, the engine operated conventionally, burning kerosene. In the second stage, co-combustion of kerosene and hydrogen occurred in the engine. The numerical analysis enabled the visualization of the flow phenomenon for these stages within the considered rotational speeds. The analysis examined flow in domains where the gap was included and excluded. This gap was created by the different diameters of the container opening and the engine nozzle outlet. The study showed that ignoring the gap allows for temperatures closer to the experimental values. Results deemed satisfactory were less likely to be found in vortex areas, but more likely in areas closer to the container walls and the engine exhaust stream itself. The results of the conducted tests showed that the Root Mean Square Error RMSE was within the range of 9.5–22.8% relative to the average temperature values obtained from experimental measurements. The highest turbulence intensity occurred for hydrogen co-combustion at a higher rotational speed, reaching 284% for Variant 2 and 300% for Variant 1. The largest standard deviation for both fuel types at a distance of 0.083 m from the container wall was 68.5 K for variant 2 and 76 K for variant 1. At a distance of 0.166 m from the container wall, the deviation was 76 K for variant 2 and 83.8 K for variant 1.