28 June 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMaria Allers
Maria Allers
AAAndré Ahrens
André Ahrens
MHMoritz Hitzemann
Moritz Hitzemann
HBHenrike Bock
Henrike Bock
TWThomas Wolf
Thomas Wolf
AFArne Ficks
Arne Ficks
Rapidly detecting and identifying chemical agents after a chemical release is crucial for a reliable assessment of imminent risks and provides the initial basis for defining an adequate level of protection for first responders. A drone equipped with gas detectors may quickly explore the contaminated area without exposing any first responders to the yet unknown threat. However, drones possess limitations in their capability concerning payload, operational range, and power requirements. Choosing the appropriate gas sensors for this application, thus, imposes significant technical challenges. In this work, we present a mobile ion mobility spectrometer (IMS) designed for operation with drones. The IMS is equipped with a dedicated closed gas loop, high-performance driver electronics, and wireless data transmission capabilities. The resulting performance of the UAV-mounted mobile IMS is characterized in the lab with the chemical warfare agents (CWAs) sarin (GB), tabun (GA), soman (GD), cyclosarin (GF), and sulfur mustard (HD), and further evaluated in three different field-testing scenarios using the simulation compound di(propylene glycol) methyl ether (DPM). It is thereby used to monitor the area near (i) a point source continuously emitting small quantities of a gaseous chemical, (ii) a point source suddenly releasing a limited quantity of a chemical as an aerosol, and (iii) a minor contamination of a liquid chemical on the ground. The results obtained in this work enable a well-founded estimation of the capabilities and limitations of the drone-mounted mobile IMS concerning the real-time remote detection of chemical hazards such as CWAs.

16 July 2024 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Open access
CSChristoph Schäfer
Christoph Schäfer
MAMaria Allers
Maria Allers
MHMoritz Hitzemann
Moritz Hitzemann
ANAlexander Nitschke
Alexander Nitschke
TKTim Kobelt
Tim Kobelt
SZStefan Zimmermann
Stefan Zimmermann
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.

11 July 2026 in Talanta
Verified
Journal Article
Open access
ANAlexander Nitschke
Alexander Nitschke
MAMaria Allers
Maria Allers
GGGian-Luca Gloeden
Gian-Luca Gloeden
MHMoritz Hitzemann
Moritz Hitzemann
CTChristian Thoben
Christian Thoben
SZStefan Zimmermann
Stefan Zimmermann
The analytical performance of ion mobility spectrometry (IMS) is frequently enhanced by coupling with gas chromatography (GC). This hyphenated approach mitigates chemical cross-sensitivities and competitive ionization effects, and enables the distinct separation of analytes even in the presence of complex background matrices. However, coupling GC to IMS can significantly extend analysis time from typically 1 s for IMS to several minutes depending on the chromatographic runtime, thus, limiting the usability of GC-IMS in time-critical scenarios. The newly developed hyper-fast GC-IMS technology offers a viable alternative that features a purpose-built dual-polarity IMS detector. It maintains the high sensitivity of IMS, provides highly selective two-dimensional separation, and achieves short analysis times in less than a minute. Consequently, hyper-fast GC-IMS is of particular interest for defense and security applications that require the urgent identification of toxic substances such as chemical warfare agents (CWAs). In this work, we evaluate the system's capability to detect nine different CWAs in the positive and negative ion polarity, yielding appropriate results with limits of detection (LOD) within the single-digit ng/μL range. Furthermore, analyzing VX in diesel-contaminated topsoil demonstrates the system's suitability for rapid identification of target analytes within complex background matrices.

30 September 2026 in Proceedings in Applied Mathematics and Mechanics
Verified
Journal Article
Open access
MMMarco Mattuschka
Marco Mattuschka
NLNoah An der Lan
Noah An der Lan
SSStefanie Schröder
Stefanie Schröder
AFArne Ficks
Arne Ficks
MDMax von Danwitz
Max von Danwitz
APAlexander Popp
Alexander Popp
Hyperspectral standoff detection systems such as Focal Plane Array (FPA) Fourier Transform Infrared (FTIR) spectrometers provide high spatial resolution in detecting airborne chemical contaminants that are invisible to the human eye but potentially hazardous. When two such systems are operated simultaneously with a suitable opening angle, they enable tomographic reconstruction of contaminant plumes with improved spatial and temporal accuracy. This work presents a mathematical model of these measurement capabilities and an algorithm to identify, localize, and quantify contaminant release sources. The objective is to develop a tool that reconstructs release locations and predicts the future plume evolution from standoff measurement data, thereby supporting early warning and situational awareness in hazardous material release scenarios. The transport of contaminants is modeled by an advection–diffusion equation, and the corresponding inverse problem for source identification is formulated accordingly. Owing to the severe ill‐posedness and underdetermination of the problem, a sparsity‐promoting regularization approach is employed together with a high‐performance optimization algorithm. To incorporate the tomographic measurement data into the discrete formulation, a level‐set description of a threshold concentration is used, allowing the measurements to be represented independently of the computational mesh and avoiding costly remeshing procedures.

18 September 2026 in Analytical Chemistry
Verified
Journal Article
Open access
MAMaria Allers
Maria Allers
AAAndré Ahrens
André Ahrens
MHMoritz Hitzemann
Moritz Hitzemann
SZStefan Zimmermann
Stefan Zimmermann
AFArne Ficks
Arne Ficks
Ion mobility spectrometry (IMS) is widely used for on-site detection of chemical warfare agents due to its high sensitivity and rapid response times. While volatile G-series nerve agents can be detected directly in the gas phase, detection of low-volatility agents such as VX or A-series nerve agents (Novichoks) is considerably more challenging. For VX, indirect detection is often achieved through the volatile hydrolysis product VX-thiol, which can dominate the vapor phase above VX samples. Whether comparable volatile marker compounds exist for A-series agents has remained largely unexplored. In this study, the vapor-phase composition above small droplets of the Novichok agents A-230, A-232, and A-234 was investigated under controlled humidity conditions using IMS. Reference spectra of potential marker compounds, including N,N-diethylacetamidine and N,N-diethylacetamide, were recorded to support signal assignment. For VX, increasing humidity resulted in an increased VX-thiol response, consistent with enhanced hydrolytic formation of this volatile marker. In contrast, the expected amidine marker showed only very limited vapor-phase availability for the investigated A-series agents. Weak N,N-diethylacetamidine signals were detected for A-230 and A-232 at an elevated humidity level of 80% RH, whereas no corresponding signal was observed for A-234. N,N-Diethylacetamide was consistently detected shortly after introduction of the respective A-series samples. Pre-experimental GC–MS analysis showed that this latter compound was already present in the agent stocks, whereas N,N-diethylacetamidine remained undetected in stock samples. The initial amide signal therefore most likely reflects a preexisting volatile constituent associated with synthesis and/or storage rather than formation during the IMS experiment. Overall, the results indicate that a hydrolysis-based marker strategy analogous to VX-thiol is considerably less effective for A-230, A-232, and A-234 under the investigated conditions. No comparably robust hydrolysis-derived volatile marker was identified for the A-series agents, while preexisting volatile constituents may influence rapid gas-phase screening. The findings highlight both the potential and the limitations of extending existing IMS-based gas monitoring approaches to low-volatility nerve agents.