Rade Tomov

Dr. Rade Tomov

Technical University of Sofia, Sofia, Sofia-Grad, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Rumiana KotsilkovaRumiana Kotsilkova
Rumiana Kotsilkova
VGVladimir Georgiev
Vladimir Georgiev
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
TBTodor Batakliev
Todor Batakliev
Evgeni IvanovEvgeni Ivanov
Evgeni Ivanov
TTTsvetozar Tsanev
Tsvetozar Tsanev
This study developed a novel 3D-printable poly(vinylidene fluoride) (PVDF)-based nanocomposite incorporating 6 wt% graphene nanoplatelets (GNPs) with programmable characteristics for resistive heating applications. The results highlighted the significant effect of a controlled printing direction (longitudinal, diagonal, and transverse) on the electrical, thermal, Joule heating, and thermo-resistive properties of the printed structures. The 6 wt% GNP/PVDF nanocomposite exhibited a high electrical conductivity of 112 S·m−1 when printed in a longitudinal direction, which decreased significantly in other directions. The Joule heating tests confirmed the material’s efficiency in resistive heating, with the maximum temperature reaching up to 65 °C under an applied low voltage of 2 V at a raster angle of printing of 0°, while the heating Tmax decreased stepwise with 10 °C at the 45° and the 90° printing directions. The repeatability of the Joule heating performance was verified through multiple heating and cooling cycles, demonstrating consistent maximum temperatures across several tests. The effect of sample thickness, controlled by the number of printed layers, was investigated, and the results underscore the advantages of programmable 3D printing orientation in thin layers for enhanced thermal stability, tailored electrical conductivity, and efficient Joule heating capabilities of 6 wt% GNP/PVDF composites, positioning them as promising candidates for next-generation 3D-printed electronic devices and self-heating applications.

2 September 2023 in Molecules
Verified
Journal Article
Open access
PDF file
RTRade Tomov
Rade Tomov
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
Metallization for contacts in organic electronic nanodevices is of great importance for their performance. A lot of effects can appear at the contact/organic interface and modify the contact parameters, such as contact resistance, adhesive strength, and bonding ability. For novel materials, it is important to study the interactions with metal atoms to develop a suitable technology for contacts, fulfilling to the greatest extent the above-mentioned parameters. A novel material is carbyne, which is still under intensive research because of its great potential in electronics, especially for sensing applications. However, the most appropriate metallization strategy for carbyne-based devices is still unknown, so the interactions between carbyne and metal films should be studied to more precisely direct the development of the metallization technology, and to form contacts that are not limiting factors for device performance.

1 March 1996 in Czechoslovak Journal of Physics
Verified
Journal Article
Closed access
PDF file
VTV. Tsaneva
V. Tsaneva
RTRade Tomov
Rade Tomov
DOD. Ouzounov
D. Ouzounov
TDT. Donchev
T. Donchev

13 August 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
RTRade Tomov
Rade Tomov
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
In this work, a titanium oxide buffer layer was explored as a possible buffer electron transporting layer (ETL) with iodine-tin-based perovskite material for enhancement of a thin-film lead-free perovskite solar cell. The open-circuit voltage of the device was used as an indicator for the interface energy barrier’s change with the thickness of the TiO2. The buffer and photoabsorbing layers were deposited by vacuum reactive sputtering and a low-temperature ion-assisted process from a confocal sintered source, respectively, allowing precise tuning of the film properties and reproducibility of the solar cell behavior. The surface roughness of the buffer layers was investigated by atomic force microscopy and together with the measured absorbance spectra conclusions about the optical losses in the device were made. It was found that the highest voltage was generated from the structure with 75 nm-thick ETL. The electrical behavior of the cell with this buffer layer was additionally studied by impedance measurements. Small interface capacitance and contact resistance were obtained and considered suitable for photodetector fabrication. The practical applicability of the structure with a dual function of self-powered photodetection was demonstrated by the measurement of the response time.

13 October 2025
Verified
Conference Paper
Closed access
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
RTRade Tomov
Rade Tomov
DDDanijel Dankovic
Danijel Dankovic
VDVojkan Davidovic
Vojkan Davidovic
SSSrboljub Stanković
Srboljub Stanković
This study investigates the effects of irradiation on the performance of carbyne-based surface acoustic wave sensors for ethanol sensing. Carbyne, a carbon allotrope, shows promise in sensing applications, but its stability under radiation, relevant in nuclear and medical settings, is not investigated yet. SAW devices coated with carbyne-enriched films were exposed to 100 kRad of irradiation, and their ethanol-sensing performance was evaluated before and after exposure by measuring impedance, phase angle, resistance, capacitance, and signal response. After irradiation, a slight increase in impedance (approximately 1%) was observed across the frequency range, and the phase angle shifted, with a maximal deviation of approximately 10°. The contact resistance negligibly increased, while the interface capacitance decreased by almost one order of magnitude for some frequencies. Most importantly, the voltage difference between the output and the input signal increased from a 17 mV before irradiation to 172 mV after exposure to 100 kRad, indicating improved sensitivity. Results indicate that irradiation doesn't negatively impact sensor performance; in fact, it enhances sensitivity to ethanol. The study provides insights into the stability of carbyne coatings under harsh conditions and the reliability of carbyne-based SAW sensors following irradiation.

14 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
RTRade Tomov
Rade Tomov
Boriana R. TzanevaBoriana R. Tzaneva
Boriana R. Tzaneva
Ivo Tsvetanov IlievIvo Tsvetanov Iliev
Ivo Tsvetanov Iliev
This study investigates the impact of microresistor topology on the sensing characteristics of MoS2-based chemoresistive cortisol sensors. It is done to address the critical need for robust, non-invasive cortisol monitoring in wearable applications, where mechanical stability under strain is paramount, and to explore underexplored topological effects on sensor performance. The research is conducted by fabricating MoS2-based meander structures on flexible PDMS substrates, featuring various microresistor designs, including long-shoulder and short-shoulder topologies, both with and without integrated mechanical ribs. Sensor performance is evaluated in resistance change mode across a range of cortisol concentrations (2.5 to 500 ng/mL) and subjected to significant mechanical bending stress. Electrical parameters such as contact resistance and parasitic capacitance, as well as temperature dependence, are also analyzed. The results demonstrate that the incorporation of ribs significantly enhances the mechanical stability and preserves the reliable sensing function of the long-shoulder topology under bending stress, improving sensitivity from 0.9 kΩ/ng/mL (without ribs) to 130.6 kΩ/ng/mL (with ribs) after bending. While temperature influences baseline resistance and response magnitude consistent with MoS2 semiconductor properties and aptamer binding kinetics, the short-shoulder design, even with ribs, showed less optimal performance. The primary advantage of the proposed device lies in its enhanced mechanical reliability under continuous strain, crucial for wearable electronics, alongside a simpler design compared to complex microfluidic or optical systems, thus enabling lower manufacturing costs and easier mass production.