Georgeta Zegan

Prof. Dr. Georgeta Zegan


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Elena-Raluca BaciuElena-Raluca Baciu
Elena-Raluca Baciu
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
AVAnca-Mihaela Vitalariu
Anca-Mihaela Vitalariu
CBConstantin BACIU
Constantin BACIU
Nicanor CimpoesuNicanor Cimpoesu
Nicanor Cimpoesu
MMmurariu_alice MURARIU
murariu_alice MURARIU
The surface condition of the materials involved in dentistry is significant for the subsequent operations that are applied in oral cavity. Samples of Co–Cr–W alloy, obtained through selective laser melting (SLM) 3D printing, with different surface states were analyzed. Surface analysis after the 3D printing process and sandblasting was realized from microstructural, chemical composition, profilometry, droplet adhesion, scratch test, and microhardness perspectives. The results presented a hardening process and a roughness modification following the sandblasting procedure, a better adhesion of the liquid droplets, the appearance of micro-cracks during the scratch test, and the oxidation of the sample after the 3D printing process and surface processing.

13 July 2018 in Metals
Verified
Journal Article
Open access
PDF file
Nicanor CimpoesuNicanor Cimpoesu
Nicanor Cimpoesu
FSFlorin Sandulache
Florin Sandulache
Bogdan IstrateBogdan Istrate
Bogdan Istrate
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
GZGeorgeta Zegan
Georgeta Zegan
Nowadays, alongside metallic biomaterials, there is increasing interest in using degradable metals in an appreciable number of medical applications. There are new kinds of metallic biomaterials for medical applications and many new findings have been reported over the past few years. Iron-based materials are a solution for biodegradable applications based on their mechanical and chemical properties. In order to control the corrosion rate of the Fe10Mn6Si alloy, we proposed the use of two additional elements, Ca and Mg, as corrosion promoters. The new material was obtained in an air-controlled atmosphere furnace after five melting operations. The material was in vitro analyzed from a corrosion resistance point of view. The experiments were realized by immersion (7, 14, and 30 days) in simulated body fluid (SBF) solution at 37 °C and a constant pH, and by electrochemical tests (electrochemical impedance spectroscopy (EIS), linear polarization (LP), cyclic polarization (CP)). Material surfaces before and after corrosion tests were analyzed through scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD) techniques. A discussion on the degradation rate of the material was realized from a comparison of the results. The results presented good composition homogeneity after the re-melting stages, with low percentages of Ca and Mg in the material, but with an adequate spread in the alloy.

12 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
ARAna-Maria Roman
Ana-Maria Roman
VGVictor Geantă
Victor Geantă
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
Corneliu MunteanuCorneliu Munteanu
Corneliu Munteanu
Lohan Nicoleta-MonicaLohan Nicoleta-Monica
Lohan Nicoleta-Monica
NINicoleta Ioanid
Nicoleta Ioanid
Special materials are required in many applications to fulfill specific medical or industrial necessities. Biodegradable metallic materials present many attractive properties, especially mechanical ones correlated with good biocompatibility with vivant bodies. A biodegradable iron-based material was realized through electric arc-melting and induction furnace homogenization. The new chemical composition obtained presented a special property named SME (shape memory effect) based on the martensite transformation. Preliminary results about this special biodegradable material with a new chemical composition were realized for the chemical composition and structural and thermal characterization. Corrosion resistance was evaluated in Ringer’s solution through immersion tests for 1, 3, and 7 days, the solution pH was measured in time for 3 days with values for each minute, and electro-corrosion was measured using a potentiostat and a three electrode cell. The mass loss of the samples during immersion and electro-corrosion was evaluated and the surface condition was studied by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). SME was highlighted with differential scanning calorimetry (DSC). The results confirm the possibility of a memory effect of the materials in the wrought case and a generalized corrosion (Tafel and cyclic potentiometry and EIS) with the formation of iron oxides and a corrosion rate favorable for applications that require a longer implantation period.

7 January 2023 in Crystals
Verified
Journal Article
Open access
PDF file
ARAna-Maria Roman
Ana-Maria Roman
Ionelia VoiculescuIonelia Voiculescu
Ionelia Voiculescu
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
Bogdan IstrateBogdan Istrate
Bogdan Istrate
RCRomeu Chelariu
Romeu Chelariu
MMmurariu_alice MURARIU
murariu_alice MURARIU
The medical applications of degradable iron-based biomaterials have been targeted by re-searchers due to their special properties that they present after alloying with various elements and different technological methods of obtaining. Compared to other biodegradable materials, iron-based alloys are designed especially for the low production costs, the non-magnetism obtained by alloying with Mn, and the shape memory effect (SME) following the alloying with Si, which is necessary in medical applications for which it could replace nitinol successfully. Alloying with new elements could improve the mechanical properties, the degradation rate, and the transformation temperatures corresponding to the SME. This paper presents the results from the study of FeMnSi-Al alloy as a biodegradable material. The X-ray diffraction (XRD) method was used to identify the phases formed in the experimental Fe-Mn-Si-Al alloy, and the SME was studied by differential scanning calorimetry (DSC). In vitro tests were performed by immersing the samples in Ringer’s biological solution for different time intervals (1, 3, and 7 days). The chemical composition of the samples, as well as the compounds resulting from the immersion tests, were evaluated by energy dispersive X-ray (EDS). Scanning electron microscopy (SEM) was used for the microstructural analysis and for highlighting the surfaces subjected to contact with the electrolyte solution. The corrosion rate (CR, mm/yr.) was calculated after mass loss, sample surface area, and immersion time (h) (at 37 °C). Samples were subjected to electro-corrosion tests using electrochemical impedance spectroscopy (EIS) and Tafel linear and cyclic potentiometry.

12 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
CPCatalin Panaghie
Catalin Panaghie
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
Bogdan IstrateBogdan Istrate
Bogdan Istrate
Nicanor CimpoesuNicanor Cimpoesu
Nicanor Cimpoesu
MBMihai-Adrian Bernevig
Mihai-Adrian Bernevig
ASAlina Sodor
Alina Sodor
Zinc biodegradable alloys attracted an increased interest in the last few years in the medical field among Mg and Fe-based materials. Knowing that the Mg element has a strengthening influence on Zn alloys, we analyze the effect of the third element, namely, Y with expected results in mechanical properties improvement. Ternary ZnMgY samples were obtained through induction melting in Argon atmosphere from high purity (Zn, Mg, and Y) materials and MgY (70/30 wt%) master alloys with different percentages of Y and keeping the same percentage of Mg (3 wt%). The corrosion resistance and microhardness of ZnMgY alloys were compared with those of pure Zn and ZnMg binary alloy. Materials were characterized using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD), linear and cyclic potentiometry, and immersion tests. All samples present generalized corrosion after immersion and electro-corrosion experiments in Dulbecco solution. The experimental results show an increase in microhardness and indentation Young Modulus following the addition of Y. The formation of YZn12 intermetallic phase elements with a more noble potential than pure Zinc is established. A correlation is obtained between the appearance of new Y phases and aggressive galvanic corrosion.

3 April 2023 in Crystals
Verified
Journal Article
Open access
PDF file
MLMarian Lutcanu
Marian Lutcanu
Ramona CimpoesuRamona Cimpoesu
Ramona Cimpoesu
MAMARIOARA ABRUDEANU
MARIOARA ABRUDEANU
Corneliu MunteanuCorneliu Munteanu
Corneliu Munteanu
SMSorin Moga
Sorin Moga
MMmurariu_alice MURARIU
murariu_alice MURARIU
Ceramic coatings have many advantages for industrial and medical applications due to their exceptional properties. Ceramic coatings with a thickness of approximately 45 μm, after grinding, were grown using a robotic arm that used the atmospheric plasma spraying procedure. The thermal shock stresses—a common situation in applications but difficult to reproduce under laboratory conditions—of the ceramic layers on top of the metal substrate was achieved using solar energy focused by a concentrating mirror, based on experiments conducted in the CNRS-PROMES laboratory, UPR 8521, belonging to the French National Centre for Scientific Research (CNRS). The ceramic layers showed excellent stability at 1000 °C, even at high heating or cooling rates. At high temperatures (above 1800 °C), the exfoliation of the complex ceramic layer was observed. No differences in the structural, phase, mechanical or adhesion properties of the ceramic layer were observed after the thermal shock cycles (in the literature, there have been quite few reports regarding the properties of the ceramic layers after the thermal shock application). Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), atomic force microscopy (AFM) and X-ray diffraction (XRD) techniques were used to characterize the complex ceramic coating and the effects of thermal shock cycling. The phases and chemical composition of the complex coatings remained similar, insensitive to thermal shock at 1000 °C, consisting of a mixture of crystalline yttrium zirconium oxide and α and γ alumina. For all cases, the main residual stress state was tensile. After 5 or 10 cycles of thermal shocks, a smoothing of the residual stress state was observed in the investigated area. A higher temperature (above 1800 °C), applied as thermal shock, led to higher residual stresses and resulted in large cracks and the spallation of the coating layer.