In order to establish the prediction model of radar equipment in multisource complex electromagnetic environment, the blocking effect and false alarm interference effect caused by single-frequency CW (continuous wave) electromagnetic interference on typical radar equipment are studied. Taking a certain sweep radar as the research object, the equivalent injection test of EMI (electromagnetic interference) is carried out. Based on the theory of radar front door coupling, the interference mechanism of EMI to radar receiver RF front end is revealed, and the variation law of blocking target and false alarm target level is analyzed. The results show that, under the single-frequency CW-EMI, the target echo level decreases with the increase of the interference field strength, and the false alarm level increases with the increase of the interference field strength. The blocking jamming sensitive bandwidth is about , and the false alarm jamming sensitive bandwidth is about .
8 December 2022 in IEEE Transactions on Electromagnetic Compatibility
In order to evaluate the viability of frequency equipment in complex electromagnetic environment, the electromagnetic radiation effect evaluation model of random noise is established based on the analysis of the blocking effect mechanism of frequency equipment. Through MATLAB calculation, the corresponding relationship table between the ratio of the critical interference field strength effective value of single frequency continuous wave and sinusoidal amplitude modulation wave and the key parameters of the model is given, and the prediction method of noise electromagnetic interference of frequency equipment is proposed. Taking a Beidou navigation receiver as the test object, the accuracy of the noise electromagnetic radiation blocking effect model is verified by single frequency continuous wave, random noise and narrowband noise electromagnetic radiation blocking effect test, and the maximum error is only 1.51 dB, which indicates that the model and prediction method proposed in this article can accurately evaluate and predict the electromagnetic radiation interference of random noise.
8 November 2021 in IEEE Transactions on Electromagnetic Compatibility
High field intensity electromagnetic radiation effect test is difficult to simulate in large-scale space, and the existing bulk current injection (BCI) technology has a limited application of the nonlinear system test. Starting from the coupling mechanism of shielded wire, an analysis model about the response of the equipment under test (EUT) is built-in radiation and injection conditions. In addition, the equivalent corresponding relationship originates between the injected excitation source voltage and the radiation field intensity. The basis for obtaining the source of the injection excitation and performing extrapolation tests is found, and the test method of BCI replacing high field intensity electromagnetic radiation is developed. Subsequently, the passing-through load and communication station tests are performed to verify the theoretical derivation and the test method. As indicated from the research results, the BCI is capable of accurately replacing the high field electromagnetic radiation effect test of the EUT, and the maximum test error reaches 2.7 dB, capable of satisfying the actual needs of the project.
15 July 2020 in International Journal of Antennas and Propagation
Two hypotheses for the blocking effect mechanisms under the electromagnetic radiation are presented, and the corresponding dual-frequency interference prediction models are proposed, which can be used to predict the working state of equipment under the condition that the single-frequency susceptibility is known. By taking a radar and a communication radio as the EUT, the experiments of dual-frequency continuous wave electromagnetic radiation are designed and carried out to verify the prediction models. The test results show that the sensitive bandwidth of blocking interference effect for the tested radar and the communication station is consistent with their working bandwidth, respectively. By substituting the test data into the proposed prediction models, the prediction errors of the models are less than 13%. Moreover, it can be found that the tested radar is more sensitive to the peak value of electric field, and the tested communication station is more sensitive to the effective value of electric field.
In the test of the electromagnetic radiation blocking effect of the navigation receiver, it is found that the sensitivity of the navigation receiver to single frequency continuous waves and sinusoidal amplitude modulation waves will change with the change in the satellite useful signal strength. This phenomenon reflects that the sensitivity of frequency equipment to multi-frequency electromagnetic radiation is not fixed to a certain extent. In order to make up for the deficiency that the existing multi-frequency electromagnetic radiation evaluation methods can only deal with a single situation, this paper uses the time delay characteristics of the circuit response, introduces the concepts of normalized interference levels and signal duty cycles, establishes the evaluation model of the multi-frequency non-intermodulation electromagnetic radiation blocking effect of frequency equipment, and puts forward the prediction method of the multi-frequency electromagnetic radiation blocking effect of frequency equipment. Taking a certain type of BeiDou navigation receiver as the test object, the single-frequency continuous wave and double-frequency continuous wave electromagnetic radiation blocking effect tests are carried out by using the full-level irradiation method. The test data are substituted into the model established in this paper for verification. The results show that the maximum evaluation error of the model is 2.23 dB. The model and the effect prediction method established in this paper are of great significance for the survival ability evaluation of frequency equipment in complex electromagnetic environments.
1 January 2024 in IEEE Transactions on Instrumentation and Measurement
Under laboratory conditions, it is challenging to perform the high-field-intensity radiation sensitivity measurement on the two-wire coupled channel of the equipment under test (EUT), and the current equivalent measurement method is useless for nonlinear systems. The calculation is performed by building the response calculation model of the EUT under radiation and injection circumstances. The linear correspondence between the injection source and the radiation field is determined on the basis of utilizing a high-linearity current probe with a primary turn larger than 1. The equivalent measurement method for high-field-intensity radiation sensitivity of the two-wire interconnection system is optimized, and the nonlinear EUT can also be applied, which is closer to the actual situation under the radiation conditions and simplifies the operation steps. The CST software and the laser distance measurement sensor test are verified, and the test errors are less than 3 dB, which complies with the engineering requirements.