High field intensity electromagnetic radiation effect test is difficult to simulate in large-scale space, and the existing bulk current injection (BCI) technology has a limited application of the nonlinear system test. Starting from the coupling mechanism of shielded wire, an analysis model about the response of the equipment under test (EUT) is built-in radiation and injection conditions. In addition, the equivalent corresponding relationship originates between the injected excitation source voltage and the radiation field intensity. The basis for obtaining the source of the injection excitation and performing extrapolation tests is found, and the test method of BCI replacing high field intensity electromagnetic radiation is developed. Subsequently, the passing-through load and communication station tests are performed to verify the theoretical derivation and the test method. As indicated from the research results, the BCI is capable of accurately replacing the high field electromagnetic radiation effect test of the EUT, and the maximum test error reaches 2.7 dB, capable of satisfying the actual needs of the project.
1 January 2024 in IEEE Transactions on Instrumentation and Measurement
Under laboratory conditions, it is challenging to perform the high-field-intensity radiation sensitivity measurement on the two-wire coupled channel of the equipment under test (EUT), and the current equivalent measurement method is useless for nonlinear systems. The calculation is performed by building the response calculation model of the EUT under radiation and injection circumstances. The linear correspondence between the injection source and the radiation field is determined on the basis of utilizing a high-linearity current probe with a primary turn larger than 1. The equivalent measurement method for high-field-intensity radiation sensitivity of the two-wire interconnection system is optimized, and the nonlinear EUT can also be applied, which is closer to the actual situation under the radiation conditions and simplifies the operation steps. The CST software and the laser distance measurement sensor test are verified, and the test errors are less than 3 dB, which complies with the engineering requirements.
18 September 2023 in Measurement Science and Technology
To address the problem of the difference in temperature between the exposed and amorce-filled state of the bridge wire in the fiber optic thermometry, this paper proceeds from a mathematical model of the temperature rise of the hot bridge wire electro-explosive device (EED), the relationship between the critical ignition temperature and the current of hot bridge wire EED is discussed. Combining thermal ignition theory, the technique of measurement and calibration the critical ignition temperature of hot bridge wire EED is proposed, and the technique is validated by injection versus radiation. The results show that the critical ignition temperature of the tested hot bridge wire EED obtained by testing and calibration is 337.53 °C. The 50% ignition field strength of the hot bridge wire EED under radiation conditions obtained by the up-and-down method test is 1271 V m−1, while the equivalent ignition field strength determined from the critical ignition temperature under the same radiation conditions is 1345 V m−1, the error between the two is only 0.49 dB, which demonstrates the high accuracy of the proposed measurement and calibration technique.
In unshielded two-wire circuits of weapon systems, the equipment at both ends of the cable needs to be tested at the same time. The theoretical model of substituting double bulk current injection (DBCI) for high-intensity radiated field (HIRF) electromagnetic radiation is established, which aims to calculate the relationship between the injection excitation voltage source and the radiation field intensity. Additionally, the conditions required for linear extrapolation is clarified. Subsequently, the test method of using DBCI for the HIRF radiated susceptibility (RS) is proposed. Next, the verification of the CST studio and the pass-through load test are performed. All results shows that the test method can avoid the influence of the impedance parameters of the two equipment at both ends, which can be applied to nonlinear terminals for the HIRF RS test.
To solve the problem of testing the sensitivity under electromagnetic pulse radiation for a hot bridge wire electro-explosive device (EED), this paper simulated and analyzed the correlation between the critical ignition current under steady and pulse excitation. The simulation results showed that, under single pulse excitation, the critical ignition current of the EED decreases with the increase in the pulse width, and the variation law can be divided into three pieces: adiabatic, transition, and constant; while under pulse train excitation, due to the thermal cumulative effect, the critical ignition current is related to both material properties and excitation parameters. By analyzing the simulation results and considering the thermal ignition theory, the mathematical model of the critical ignition current under pulse excitation was established, and the mathematical model showed that under pulse train excitation, the critical ignition current is relevant not only to the single pulse excitation critical ignition current, pulse period, and duty cycle, but also to the ratio of single pulse and steady excitation critical ignition current and the thermal time constant. It was verified that the errors between the theoretical values obtained from the mathematical model and the results obtained from the simulation were within 2.5%.
Radiation effect test cannot be performed in large-scale space simulations of a strong field electromagnetic environment, and existing BCI (bulk current injection) technology employed for nonlinear system tests is subjected to its limitation. Given this, the present study analyzes the equivalent radiation test method of BCI in the parallel double-line coupling channel. To be specific, the response analysis models of the EUT (equipment under test) under the radiation condition and the injection condition are developed with the nonlinear response system as the EUT. In addition, the corresponding equivalent relationship is derived between the voltage of the injection excitation source and the radiation field intensity. Subsequently, the condition and the test method to substitute BCI for radiation are proposed and experimentally verified. As revealed from the research results, specific to nonlinear response systems, the BCI method proposed here can be accurately equated with the radiation effect test of the EUT. It is noteworthy that the maximum test error only reaches 3.62 dB, capable of satisfying the actual requirements of the project.