8 November 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JSJiangning Sun
Jiangning Sun
XPXiaodong Pan
Xiaodong Pan
XLXinfu Lu
Xinfu Lu
HWHaojiang Wan
Haojiang Wan
GWGuanghui Wei
Guanghui Wei
High field intensity electromagnetic radiation effect test is difficult to simulate in large-scale space, and the existing bulk current injection (BCI) technology has a limited application of the nonlinear system test. Starting from the coupling mechanism of shielded wire, an analysis model about the response of the equipment under test (EUT) is built-in radiation and injection conditions. In addition, the equivalent corresponding relationship originates between the injected excitation source voltage and the radiation field intensity. The basis for obtaining the source of the injection excitation and performing extrapolation tests is found, and the test method of BCI replacing high field intensity electromagnetic radiation is developed. Subsequently, the passing-through load and communication station tests are performed to verify the theoretical derivation and the test method. As indicated from the research results, the BCI is capable of accurately replacing the high field electromagnetic radiation effect test of the EUT, and the maximum test error reaches 2.7 dB, capable of satisfying the actual needs of the project.

1 January 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JSJiangning Sun
Jiangning Sun
XLXinfu Lu
Xinfu Lu
GWGuanghui Wei
Guanghui Wei
HWHaojiang Wan
Haojiang Wan
XPXiaodong Pan
Xiaodong Pan
Under laboratory conditions, it is challenging to perform the high-field-intensity radiation sensitivity measurement on the two-wire coupled channel of the equipment under test (EUT), and the current equivalent measurement method is useless for nonlinear systems. The calculation is performed by building the response calculation model of the EUT under radiation and injection circumstances. The linear correspondence between the injection source and the radiation field is determined on the basis of utilizing a high-linearity current probe with a primary turn larger than 1. The equivalent measurement method for high-field-intensity radiation sensitivity of the two-wire interconnection system is optimized, and the nonlinear EUT can also be applied, which is closer to the actual situation under the radiation conditions and simplifies the operation steps. The CST software and the laser distance measurement sensor test are verified, and the test errors are less than 3 dB, which complies with the engineering requirements.

1 August 2016 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
XLXinfu Lu
Xinfu Lu
GWGuanghui Wei
Guanghui Wei
XPXiaodong Pan
Xiaodong Pan
LFLisi Fan
Lisi Fan
HWHaojiang Wan
Haojiang Wan
A dual‐port pulsed differential‐mode current injection (DPDCI) method is proposed for high‐level wide‐band electromagnetic pulse (EMP) radiated susceptibility testing of interconnected systems. By employing the designed wide‐band differential‐mode (DM) coupling device, the susceptibility of the equipment under test (EUT) at both ends can be assessed at the same time. In order to enforce the equivalence between EMP radiation and DPDCI, the methods to obtain the waveforms of the two equivalent injection sources and their time delay difference are proposed. By using the linear extrapolation method, the results for high‐level EMP radiation can be reproduced by DPDCI even if the responses of the two EUTs are non‐linear. To confirm the effectiveness of the proposed method, the conversion of common‐mode interference into DM disturbance on the cable inside the EUT is assessed by experiment and the impact of connecting the injection devices into the system is discussed. By using a typical interconnected system composed of a coaxial cable and typical non‐linear equipment at both ends, the feasibility of the proposed method is verified.

28 June 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
XLXuxu Lyu
Xuxu Lyu
GWGuanghui Wei
Guanghui Wei
MSMingchang Song
Mingchang Song
JSJiangning Sun
Jiangning Sun
Hong-Ze ZhaoHong-Ze Zhao
Hong-Ze Zhao
XLXinfu Lu
Xinfu Lu
To solve the problem of testing the sensitivity under electromagnetic pulse radiation for a hot bridge wire electro-explosive device (EED), this paper simulated and analyzed the correlation between the critical ignition current under steady and pulse excitation. The simulation results showed that, under single pulse excitation, the critical ignition current of the EED decreases with the increase in the pulse width, and the variation law can be divided into three pieces: adiabatic, transition, and constant; while under pulse train excitation, due to the thermal cumulative effect, the critical ignition current is related to both material properties and excitation parameters. By analyzing the simulation results and considering the thermal ignition theory, the mathematical model of the critical ignition current under pulse excitation was established, and the mathematical model showed that under pulse train excitation, the critical ignition current is relevant not only to the single pulse excitation critical ignition current, pulse period, and duty cycle, but also to the ratio of single pulse and steady excitation critical ignition current and the thermal time constant. It was verified that the errors between the theoretical values obtained from the mathematical model and the results obtained from the simulation were within 2.5%.

11 July 2022 in Electronics
Verified
Journal Article
Open access
PDF file
JSJiangning Sun
Jiangning Sun
XPXiaodong Pan
Xiaodong Pan
XLXinfu Lu
Xinfu Lu
HWHaojiang Wan
Haojiang Wan
GWGuanghui Wei
Guanghui Wei
In unshielded two-wire circuits of weapon systems, the equipment at both ends of the cable needs to be tested at the same time. The theoretical model of substituting double bulk current injection (DBCI) for high-intensity radiated field (HIRF) electromagnetic radiation is established, which aims to calculate the relationship between the injection excitation voltage source and the radiation field intensity. Additionally, the conditions required for linear extrapolation is clarified. Subsequently, the test method of using DBCI for the HIRF radiated susceptibility (RS) is proposed. Next, the verification of the CST studio and the pass-through load test are performed. All results shows that the test method can avoid the influence of the impedance parameters of the two equipment at both ends, which can be applied to nonlinear terminals for the HIRF RS test.

4 July 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JSJiangning Sun
Jiangning Sun
XLXinfu Lu
Xinfu Lu
GWGuanghui Wei
Guanghui Wei
HWHaojiang Wan
Haojiang Wan
XPXiaodong Pan
Xiaodong Pan
XLXiaopeng Li
Xiaopeng Li
To address the significant challenges of testing the electromagnetic pulse (EMP) radiation effects on the shielded multi-core wire coupling channel in large-scale weapon systems, a theoretical model has been developed that utilizes bulk current injection (BCI) as an equivalent substitute for high-field-intensity electromagnetic radiation. This model establishes equivalence based on the equal terminal responses of each wire pair under both radiated and injected conditions. The equivalent relationship between the injection source and the radiation field intensity for each wire pair is linear and uniform. This relationship, being independent of the terminal impedance at the equipment under test (EUT), enables the calculation of the equivalent injection waveforms. The equivalent testing method for strong EMP radiation effects is proposed and demonstrated by experimental validation. The average correlation coefficient of response curves for each wire pair in the pass-through load simulating the EUT test exceeds 0.9. The maximum error observed in the airborne computer effect test is 1.48 dB. The proposed method indicates that achieving equivalence for one wire pair’s terminal response under radiated conditions ensures equivalence for the remaining wire pairs as well, demonstrating applicability to nonlinear systems.