Xuxu Lyu

Dr. Xuxu Lyu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
XLXuxu Lyu
Xuxu Lyu
GWGuanghui Wei
Guanghui Wei
XLXinfu Lu
Xinfu Lu
HWHaojiang Wan
Haojiang Wan
XDXue Du
Xue Du
Most studies assessing the safety of hot bridge wire EEDs employ temperature sensors that directly use the measurements of the temperature measurement device without analyzing the accuracy of the temperature measurement. This study establishes the response function of the exposed bridge and exposed bridge temperature rise system of hot bridge wire EEDs through the Rosenthal’s temperature rise equation and Laplace transformation as well as experimental tests, and through the response function, the response law and numerical characteristics of the two are compared and analyzed under four typical excitations. Under steady current injection and continuous-wave radiation, both exposed bridge and exposed bridge temperature measurement systems can reach thermal equilibrium, and the equilibrium temperature of both are the same. However, under pulse excitation, the temperature rise measurement value is significantly different from the actual value due to the large difference in response time of the exposed bridge (1 ms) and the exposed bridge temperature measurement device (0.82 s). Studies have shown that under steady current injection and continuous-wave radiation, temperature rise measurements can be directly applied to the safety assessment of hot bridge wire EEDs, while under pulsed conditions, temperature rise measurements cannot be directly applied.

14 December 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
XLXuxu Lyu
Xuxu Lyu
GWGuanghui Wei
Guanghui Wei
XDXue Du
Xue Du
HZHongze Zhao
Hongze Zhao
JSJiangning Sun
Jiangning Sun
Hot bridge wire electroexplosive devices (EEDs) are widely used as starting elements in aerospace and other fields. Their thermal ignition process and safety testing technology have always been a focus of research. In this paper, we construct a temperature rise model for a hot bridge wire EED by using the law of conservation of energy, and the temperature response of the bridge wire and the reagent is obtained. According to the theoretical and numerical analysis, the sensitive criterion for a hot bridge wire EED is given, and the simulation process for the critical ignition current is designed. Based on this process, the law of the influence of the bridge wire and reagent parameters on the ignition of a hot bridge wire EED was studied. The research results show that a first derivative of the reagent temperature with respect to the radial distance of greater than zero is a sensitive criterion for the ignition of a hot bridge wire EED with high accuracy. Compared with traditional numerical methods, the proposed process makes the acquisition of the critical ignition current more precise and programmable due to the use of sensitive criteria. In addition, the following significant features are noted: the critical ignition current first increases as the square root of the bridge wire radius and then linearly; the square of the critical ignition current increases linearly with the activation energy of the reagent; there is rapid exponential decay of the critical ignition current with increasing reagent combustion heat; asymptotic values are present. In engineering use, it is possible to conveniently design the ignition characteristics of a hot bridge wire EED by changing the radius of the bridge wire. This study serves as a foundational work for the safety testing of hot bridge wire EEDs and can provide theoretical guidance for the safety testing, actual production and use of hot bridge wire EEDs.

18 September 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
XLXuxu Lyu
Xuxu Lyu
GWGuanghui Wei
Guanghui Wei
XLXinfu Lu
Xinfu Lu
XDXue Du
Xue Du
JSJiangning Sun
Jiangning Sun
HZHongze Zhao
Hongze Zhao
To address the problem of the difference in temperature between the exposed and amorce-filled state of the bridge wire in the fiber optic thermometry, this paper proceeds from a mathematical model of the temperature rise of the hot bridge wire electro-explosive device (EED), the relationship between the critical ignition temperature and the current of hot bridge wire EED is discussed. Combining thermal ignition theory, the technique of measurement and calibration the critical ignition temperature of hot bridge wire EED is proposed, and the technique is validated by injection versus radiation. The results show that the critical ignition temperature of the tested hot bridge wire EED obtained by testing and calibration is 337.53 °C. The 50% ignition field strength of the hot bridge wire EED under radiation conditions obtained by the up-and-down method test is 1271 V m−1, while the equivalent ignition field strength determined from the critical ignition temperature under the same radiation conditions is 1345 V m−1, the error between the two is only 0.49 dB, which demonstrates the high accuracy of the proposed measurement and calibration technique.

28 June 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
XLXuxu Lyu
Xuxu Lyu
GWGuanghui Wei
Guanghui Wei
MSMingchang Song
Mingchang Song
JSJiangning Sun
Jiangning Sun
Hong-Ze ZhaoHong-Ze Zhao
Hong-Ze Zhao
XLXinfu Lu
Xinfu Lu
To solve the problem of testing the sensitivity under electromagnetic pulse radiation for a hot bridge wire electro-explosive device (EED), this paper simulated and analyzed the correlation between the critical ignition current under steady and pulse excitation. The simulation results showed that, under single pulse excitation, the critical ignition current of the EED decreases with the increase in the pulse width, and the variation law can be divided into three pieces: adiabatic, transition, and constant; while under pulse train excitation, due to the thermal cumulative effect, the critical ignition current is related to both material properties and excitation parameters. By analyzing the simulation results and considering the thermal ignition theory, the mathematical model of the critical ignition current under pulse excitation was established, and the mathematical model showed that under pulse train excitation, the critical ignition current is relevant not only to the single pulse excitation critical ignition current, pulse period, and duty cycle, but also to the ratio of single pulse and steady excitation critical ignition current and the thermal time constant. It was verified that the errors between the theoretical values obtained from the mathematical model and the results obtained from the simulation were within 2.5%.

17 February 2023 in Materials Research Express
Verified
Journal Article
Open access
PDF file
SLShaojie Li
Shaojie Li
JYJun Yan
Jun Yan
HMHuijuan Ma
Huijuan Ma
XLXuxu Lyu
Xuxu Lyu
YZYuling Zhang
Yuling Zhang
SDShiguo Du
Shiguo Du
This study aims to investigate the hybrid effects of carbon nanotubes (CNTs) and steel fiber (SF) on dynamic mechanical behavior of ultra-high performance concrete (UHPC) under the high-speed dynamic loading effects. The functionalized CNTs content varied from 0.0% to 0.20%, and SF volume content was added from 0.5% to 2.0%. The UHPC specimens were tested at strain rates ranging from about 60 s-1 to 240 s-1 using the split Hopkinson pressure bar. The dynamic behavior of specimens was evaluated in terms of stress–strain relationships, energy absorption capacity and failure patterns. Test results show that dynamic compressive properties of UHPC are strongly sensitive to strain rates. The individual addition of CNTs obviously improves the dynamic performance of plain UHPC, and there exists an optimal CNTs content of about 0.10% to achieve better improvement effects. The dynamic increase factor (DIF) is almost unrelated to CNTs content but closely correlated to strain rate variations, which can be well described by a modified empirical formula. Furthermore, it is found that the hybrid CNTs and SF display more significant reinforcing effects on dynamic properties of UHPC, as the UHPC specimen with 0.10% CNTs and 2.0% SF exhibits the highest dynamic compressive strength and toughness. Meanwhile, UHPC reinforced by hybrid fibers is less sensitive to high strain rates compared to plain UHPC. From microscopic observations, it is reasonably believed CNTs and SF exert synergistic reinforcing effects on UHPC matrix in view of their respective characteristics, which are more significant in improving the interfacial transition zone (ITZ) structure between SF and the surrounding matrix. This work promotes a fundamental understanding for the reinforcing effects of CNTs on UHPC, and provides an effective strategy to reinforce UHPC from multiscale perspectives.

2 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
Hong-Ze ZhaoHong-Ze Zhao
Hong-Ze Zhao
GWGuanghui Wei
Guanghui Wei
XPXiaodong Pan
Xiaodong Pan
XDXue Du
Xue Du
XLXuxu Lyu
Xuxu Lyu
When typical radar equipment is subjected to single-frequency electromagnetic radiation, the radar display interface forms a pseudo-signal, resulting in the misjudgment of real targets. Based on the working principle of stepped-frequency radar ranging, the effect mechanism of radar equipment pseudo-signal interference is revealed. Taking a Ku band stepped-frequency ranging radar as the test object, the pseudo-signal interference effect test of single-frequency electromagnetic radiation is carried out in this study. The pseudo-signal level value of 6 dBmV is selected as the sensitive criterion of the pseudo-signal interference effect. Through experiments, the variation curves of the pseudo-signal level values of the sensitive frequency bands and the typical frequency points inside and outside the band with the field strength of the single-frequency interference are obtained. Based on the nonlinear distortion analysis of the receiving circuit, the variation laws of the pseudo-signal level values inside and outside the band are explained, respectively. The experimental results show that there are at least seven pseudo-signal interference-sensitive bands in the tested radar, and the first pseudo-signal strength is only related to the interference signal strength. The essence of the second type of pseudo-signal interference is intermodulation interference, and the pseudo-signal level is related to the interference signal and the useful signal strength.