This paper presents the results of numerical and experimental investigation of thermal convection near heat emitting surfaces of an electric device. For the intensification of thermal convection, special vertical channels were formed near the heat emitting surfaces of the device. An experimental test has proved that there is an optimal length of the channels - thermal convection is the most intensive then. Air velocity vectors close to heat emitting surfaces are presented with the use of Ansys software. Due to vertical channels, it is possible to increase the current-carrying capacity of electric devices.
The article presents the results of experimental studies on a flat plate radiator. The influence of curtains made of materials of different structures and permeabilities on the temperature fields in the space around the radiator and the heating power of the radiator was checked. Temperature studies concern the gap between the front panel of the radiator and the hung material. The heating power was calculated for the individual variants tested (with or without a cover). The highest heating power was shown to be achieved by the radiator without a cover, which was 319.8 W. The radiator with guipure cover had 319.3 W, while the lowest power was achieved by the radiator with cotton curtain, which was 277.0 W. Based on the experiment conducted, screening factors were given. They were established in relation to the curtains tested and their effect on the heat power of the radiator.
17 December 2024 in Journal of Building Engineering