Mohamed Elsaharty

Dr. Mohamed Elsaharty

Research Institute for Autonomous Systems
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
NZNahla E. Zakzouk
Nahla E. Zakzouk
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
AAahmed abdelsalam
ahmed abdelsalam
AHAhmed A. Helal
Ahmed A. Helal
BWBarry W. Williams
Barry W. Williams
Variable‐step incremental conductance (Inc.Cond.) technique, for photovoltaic (PV) maximum power point tracking, has merits of good tracking accuracy and fast convergence speed. Yet, it lacks simplicity in its implementation due to the mathematical division computations involved in its algorithm structure. Furthermore, the conventional variable step‐size, based on the division of the PV module power change by the PV voltage change, encounters steady‐state power oscillations and dynamic problems especially under sudden environmental changes. In this study, an enhancement is introduced to Inc.Cond. algorithm in order to entirely eliminate the division calculations involved in its structure. Hence, algorithm implementation complexity is minimised enabling the utilisation of low‐cost microcontrollers to cut down system cost. Moreover, the required real processing time is reduced, thus sampling rate can be improved to fasten system response during sudden changes. Regarding the applied step‐size, a modified variable‐step size, which depends solely on PV power, is proposed. The latter achieves enhanced transient performance with minimal steady‐state power oscillations around the MPP even under partial shading. For proposed technique's validation, simulation work is carried out and an experimental set up is implemented in which ARDUINO Uno board, based on low‐cost Atmega328 microcontroller, is employed.

5 February 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
Alvaro LunaAlvaro Luna
Alvaro Luna
JCJose Ignacio Candela
Jose Ignacio Candela
Pedro RodriguezPedro Rodriguez
Pedro Rodriguez

1 May 2014
Verified
Conference Paper
Closed access
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
HAH. A. Ashour
H. A. Ashour
The increased demand for grid-connected inverters for connection of renewable energy sources raises the issue of harmonics injected to the grid. Such inverters must comply with the standards specification of current harmonics injected to the grid. Such regulations can be maintained using passive filters connected between the inverter and grid. Design of such filters is a challenging problem when considering factors for the filter design such as inverter specifications and ratings. This paper proposes a trial-and-error based algorithm to obtain viable L and LCL filter parameters which comply with standards requirements and inverter ratings. Filter parameters are studied and the IEEE-1547 standard is adopted for the algorithm decision making. The result is a various combination of filter parameters that can be used which all satisfy the required criteria. By means of simulation the resulting parameters are evaluated.

1 November 2011
Verified
Conference Paper
Closed access
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
MHMostafa Saad Hamad
Mostafa Saad Hamad
HAH.A. Ashour
H.A. Ashour
Current controlled inverter using hysteresis controller is popular due to the simplicity of the algorithm implementation with a robust dynamic response. However, the controller action requires the use of analogue circuitry to maintain its characteristics which lacks the interfacing, maintenance, flexibility, and integration of a digital system. In this paper, a digital hysteresis controller based on sampling the feedback signal and applying control action at a fixed interval is investigated. The controller is applied on three proposed configurations for a single phase grid connected inverter with a designed LCL filter and a primary control loop on the filter inductor current. Parameters affecting the hysteresis controller primary characteristics are investigated and a selection criteria of filter parameters is derived. To eliminate performance issues arising from parameters mismatching and variable switching frequency, adaptive hysteresis band calculation and a secondary control loop is proposed. By means of simulation and experimental implementation, the performance of the configurations is evaluated.

8 June 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
JRJoan Rocabert
Joan Rocabert
JCJose Ignacio Candela
Jose Ignacio Candela
PRPedro Rodriguez
Pedro Rodriguez
This paper presents the three-phase custom power active transformer (CPAT), characterized by the integration of power electronics in a transformer to facilitate grid services. Such integration enables step-up/step-down transformation between primary and secondary as well as shunt and series compensation services to the power system through a single transformer. The CPAT can empower the grid with flexible ac transmission system and power quality services such as power flow control, reactive power compensation, active filter, and voltage regulation through a single monolithic transformer. In this paper, designs of the three-phase CPAT are realized and analyzed based on their equivalent magnetic circuit as well as their structure requirements and constraints. Simulation analysis of the three-phase CPAT clarifies its capability to actively regulate power flow between the primary and secondary windings as well as achieve grid harmonic current compensation. Moreover, through real-time simulations and an experimental prototype, the merits and performance of the three-phase CPAT were further validated.

27 December 2016 in Electric Power Components and Systems
Verified
Journal Article
Closed access
Elyas RakhshaniElyas Rakhshani
Elyas Rakhshani
Kumars RouzbehiKumars Rouzbehi
Kumars Rouzbehi
Mohamed ElsahartyMohamed Elsaharty
Mohamed Elsaharty
PCPedro Rodriguez Cortes
Pedro Rodriguez Cortes
This paper presents a new approach to enhance the dynamic responses of AGC in power systems by means of heuristic optimization of VSC-HVDC supplementary controllers. The upcoming power electronics-based VSC-HVDC transmission systems offer new features that would be advantageous for improving the frequency control and thus for enhancing the stability of the transmission grids. In this paper, the parameters of the proposed control modulation are tuned using Genetic Algorithm and Simulated Annealing methods. The performance of the proposed intelligent based tuning approach is assessed through MATLAB simulations for an AC/DC interconnected system. For the sake of detailed analysis, the effects of PLL and frequency measurements are also included in the VSC-HVDC system modeling. Furthermore, to show merits of the proposed strategy, a comparison between AC and DC transmissions is presented.