Arkadiusz Kaszewski

Dr. Arkadiusz Kaszewski

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BUBartlomiej Ufnalski
Bartlomiej Ufnalski
AKArkadiusz Kaszewski
Arkadiusz Kaszewski
LGLech M Grzesiak
Lech M Grzesiak
This paper presents evolutionary optimization of the linear quadratic regulator (LQR) for a voltage-source inverter with an LC output filter. The procedure involves particle-swarm-based search for the best weighting factors in the quadratic cost function. It is common practice that the weights in the cost function are set using the guess-and-check method. However, it becomes quite challenging, and usually very time-consuming, if there are many auxiliary states added to the system. In order to immunize the system against unbalanced and nonlinear loads, oscillatory terms are incorporated into the control scheme, and this significantly increases the number of weights to be guessed. All controller gains are determined altogether in one LQR procedure call, and the originality reported here refers to evolutionary tuning of the weighting matrix. There is only one penalty factor to be set by the designer during the controller synthesis procedure. This coefficient enables shaping the dynamics of the closed-loop system by penalizing the dynamics of control signals instead of selecting individual weighting factors for augmented state vector components. Simulational tuning and experimental verification (the physical converter at the level of 21 kVA) are included.

14 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
MGMichal Gierczynski
Michal Gierczynski
LGLech M Grzesiak
Lech M Grzesiak
AKArkadiusz Kaszewski
Arkadiusz Kaszewski
This paper deals with a well-known problem of the transient DC-bias current occurring during a phase shift transition in dual active bridge (DAB) DC/DC converters. This phenomenon, if not compensated, can cause damage to the converter or deteriorate its performance. One aim of this paper is to present a solution which allows for the elimination of the undesired transient DC-bias component in current waveforms. This solution is the dual rising edge shift (DRES) compensation algorithm. It provides a very simple implementation and fast settling time within the first half of a switching period. Moreover, the solution is independent on any measurements or system parameter values. It is based on the double-sided single phase shift (DSSPS) modulation, which is described in detail along with a converter model in steady-state. Then, the mechanisms leading to the transient DC-bias are explained, and the compensation algorithm is derived. The performance of the algorithm has been tested using a laboratory prototype. A comprehensive set of tests, involving rapid step changes in power flow and frequency sweep, are provided. Finally, the features of the proposed algorithm are briefly discussed.

29 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
MGMichal Gierczynski
Michal Gierczynski
LGLech M Grzesiak
Lech M Grzesiak
AKArkadiusz Kaszewski
Arkadiusz Kaszewski
The paper describes the cascaded voltage and current control for a bidirectional DC/DC converter in Dual Active Bridge (DAB) topology. The typical DAB converter circuit was extended by additional current filters, which allow it to operate in application fields with high requirements on current ripples. The core concept of the presented solution is usage of the modified Single Phase Shift (SPS) modulation, which allows to compensate for the DC-bias current occurring in dynamic states and provides a settling time of half switching cycle during transients. Its features were utilized to build a simplified dynamic model of the converter. The linear Proportional-Integral (PI) controllers are used in both voltage and current control loops. Based on the developed dynamic models, the tuning rules for both controllers were derived. In both cases, a number of the tuned parameters were reduced from two to one (which can present a great practical value for application engineers). The proposed solutions are validated based on a laboratory prototype. An important part of the experiments was devoted to non-linear effects occurring near the current limitation boundary of the system. The paper ends with a brief discussion regarding the future research directions.

1 October 2012
Verified
Conference Paper
Closed access
AKArkadiusz Kaszewski
Arkadiusz Kaszewski
LGLech M Grzesiak
Lech M Grzesiak
BUBartlomiej Ufnalski
Bartlomiej Ufnalski
The paper presents control system synthesis for a true sine wave four-leg inverter with an LC output filter. Our main goal is to ensure high quality voltage waveform for unbalanced and nonlinear loads. An LQR approach was chosen. The LQR design approach has proven effective in many industrial applications. Although weights in a cost function are usually set by guess and check method, the LQR in proposed system gives satisfactory results as far as some general and very intuitive rules are applied, e.g. the penalty coefficient for an integral of control error is a few orders of magnitude away from penalty coefficients related to plant state variables. In order to immunise system against nonlinear loads oscillatory terms are included in the control scheme. They can be tuned for typical harmonics like 5 th , 7 th , 11 th and 13 th . A novelty of the proposed solution lies in the fact that all controller gains (including all integral and oscillatory terms) are determined altogether in one LQR procedure call. Controls are calculated in rotating reference frame. Simulation (continuous and discrete) and experimental results (at the level of 10kW) are included. They establish consistent set of tests that validates effectiveness of the design approach.

1 September 2014
Verified
Conference Paper
Closed access
AKArkadiusz Kaszewski
Arkadiusz Kaszewski
AGAndrzej Galecki
Andrzej Galecki
BUBartlomiej Ufnalski
Bartlomiej Ufnalski
LGLech M Grzesiak
Lech M Grzesiak
This paper presents a control strategy for four-leg grid-connected PWM rectifiers that have an active power filtering function. The four-leg voltage source converter topology gives ability to control an input current in the neutral leg. That is important for the active power filtering function when there is an unbalanced load. The control strategy is based on a voltage oriented method that has a cascaded DC voltage and current controllers designed in a rotating reference frame. The DC voltage controller is a PI-type, whereas the input current is shaped by a full-state feedback controller. The novelty of the proposed solution is the control structure that has modified the DC voltage error signal by adding a discontinuity element and reduction the number of current signals by half. The discontinuity element is needed to provide a constant reference current signal during active power filtering operation. The paper describes in detail the design procedure for the voltage and current controllers. Numerical results for active rectification and active power filtering operations are presented and discussed. Numerical results have been obtained by using a discrete control model.