The paper presents an experimental study on the formation process of burden surface texture on the blast furnace throat and its influence on the radial distribution of gas flow. The study was performed with the application of blast furnaces equipped with a bell-type charging device using radio-isotope means for the control of burden surface texture (profile) and burden surface level, i.e., gamma locators for burden surface texture. The study was carried out under the conditions of an operating blast furnace in an iron and steel plant using a unique GEOTAPS system for automated control of geometric and temperature parameters of burden material surface on the blast furnace throat. The influence of the surface texture on the gas flow distribution was also investigated. The possibility of a self-stabilization effect for burden surface texture and gas flow in an operating blast furnace under suitable conditions was experimentally proven. As a result of the experimental study performed, four ways of energy-saving technology implementation were determined for the control of blast furnace melting based on the data on the burden surface texture and previously unknown regularities of surface layer formation of burden material on the throat of an operating blast furnace with a bell-type charging device. The main idea of the paper is the development of automated control for the radial distribution of burden material and gas flow using actual or predicted surface texture parameters as important intermediate factors that both describe the process and have a significant simultaneous influence on it.
The paper presents the results of analytical and experimental studies of the hydrodynamics of the translational−rotational motion of incompressible gas flow within a working space of a variable-geometry vortex heat generator. The terminal velocity and pressure have been identified analytically. The effect of vortex generation on the ratio of the parameters has been analyzed. A mathematical model has been developed with a simplified design scheme that simulates the movement inside a vortex channel with fixed elements. On the basis of mathematical modelling, the influence of the apparatus-constructive (AC) design of the working space of a vortex heat generator on the generation of vortices inside the apparatus has been analyzed. The influence of the main geometric and hydrodynamic parameters of the device on the indicators of its energy efficiency has been investigated. The obtained models show the critical regions where the most intense cavitation zones are possible. An analysis of the hydrodynamics of the incompressible gas motion within the working space of the newly designed vortex heat generator with variable geometry has helped define both the terminal velocity and pressure. In addition, the effect of the facility geometry on the generation of vortices favoring cavitation was determined. The model studies have been carried out in terms of liquid loading changes in the 0.001–0.01 m3/s range. The changes in a velocity field within a working channel have been analyzed for the channel geometry, where a cone angle is 0° to 25°, with 130, 70, and 40 mm widths for the working channel. It has been identified that a sufficient axial symmetry of the heat carrier along a vortex accelerator enables the heat carrier inlet through a turbulizing nozzle. The dependence of the nozzle area, the effect on the efficiency of the vortex heat generator angle of attack of the vortex accelerator, and the ratio of the length and diameter of the vortex zone of the heat generator to its energy efficiency in general have been defined experimentally. These studies could be instrumental in the design of vortex heat generators whose geometry corresponds to the current requirements concerning energy efficiency. It has been found that the geometry of the vortex accelerator improves the operation of the heat generator by 35% in comparison with similar available designs.
This study presents full transient, three-dimensional numerical models of a PV–TEG hybrid module coupled with single-phase inverter by co-simulation. The influence of factors, such as wind speed, solar radiation intensity, or ambient temperature on the PV–TEG system, was also examined. The numerical model was implemented using Ansys software which accounted the phenomena of Thomson, Seebeck, and Joule’s heat place on the TEG system. Furthermore, its impact on total electrical efficiency was studied. The heat transfer surface of the passive heat sink and forced air circulation positively affected the total heat transfer, and therefore helped to maintain the electrical efficiency at a higher level. Simulation of the single-phase inverter with a PV–TEG system allows the determination of the power characteristics of the system in real time. The results of the study presented may provide a basis for performance optimization of a practical PV–TEG-inverter hybrid system co-design.
The article reviews selected methods and techniques of agricultural biogas desulphurization. Presented is the current state of technological and measurement systems as well as raw biogas purification methods in terms of control and measurement-socio-economic aspects were also pointed out. On the example of a pilot agricultural biogas with the use of pig slurry, the required technical and technological criteria for the production and processing of agricultural biogas were indicated. The article presents the preliminary results of experimental studies on the course of changes in the volumetric composition of biogas on the basis of the average daily production of agricultural biogas.The amount of H2S in raw and purified biogas was analyzed with the proprietary biogas desulphurization method in terms of the process parameters. A novelty is the use of a developed carbon mixture (activated carbon) with turf ore (iron compounds), which allows for 100% desulfurization of raw agricultural biogas under process conditions for mesophilic fermentation. The measurement results show a clear influence of desulphurization using the proprietary adsorption-absorption technique-agricultural biogas.
The effect of basic parameters of the channels of disk pulse devices on the heat exchange efficiency was studied both analytically and experimentally, especially in terms of pulse acting on the heat carrier. A methodology to determine the main parameters, namely the pressure and the temperature of the heat carrier as well as the pulse effect on the fluid, was proposed. The mathematical models of the effect of the structural and technological parameters of the channels in the disk pulse device on the heat exchange efficiency were developed. The models’ adequacy was proved based on a series of experimental studies involving devices with one-stage and multistage systems of pulsed heat carrier processing. This enabled the development, testing, and implementation of practical construction designs of pulse disk heat generators for decentralized heating of commercial and domestic buildings with one-stage and multistage systems of pulsed heat carrier processing. Taking into account the results of the mathematical modeling, the developed method of multistage pulse action was proved experimentally and implemented in regard to the structural design of a working chamber of the disk pulse heat generator. An efficient geometry of the working chamber of the disk pulse heat generator was specified for its further integration into the system of decentralized heat supply. One of the developed heat generators with the multistage pulse action on the heat carrier was integrated into the heating system of a greenhouse complex with a 0.86–0.9 efficiency coefficient.
The research was carried out by means of implosion plasma generators with conical and hemispherical compression chambers to conduct a quantitative assessment of the boundary temperature of super dense plasma jets. It was proved experimentally that nuclear transformations in metals are caused by the impact of super dense plasma jets (11, ..., 12) × 103 kg/m3. The boundary temperature of these jets was evaluated. It was estimated that the nominal boundary temperature of the studied implosion plasma generators is 106 К. The pressure in the target at the penetration of the super dense jet (~12,000 kg/m3) at the speed of 28,000 m / sec is more than 30 ТPa. The boundary temperature was estimated and proved to depend on the pre-determined values only slightly. It was experimentally established that stable isotopes of manganese Mn55 (up to 27%) are formed in iron targets as a result of high temperature plasma jet penetration. The appearance of manganese must be related to iron transformation into stable isotopes Fe56 and Fe54. The obtained results may be applied for investigating structural changes in metals under the conditions of impulsive super high temperatures and pressures. This method can be also used as a testing ground for studying the physical conditions of forming chemical elements as well as super dense plasma jets.