This paper studies the problem of fault detection for continuous time linear switched systems in the presence of disturbance. For this purpose, a fault detection sliding mode observer approach is designed to generate the residual signal. To minimize the effect of disturbance from the residual, the problem is formulated into H∞ filtering technique to increase more robustness. To deal with the issue of the switched systems stability, the Lyapunov-Krasovskii functional method is utilized along with average dwell time, and linear matrix inequalities are formulated to derive the sufficient conditions. The residual signal is evaluated, and an adaptive threshold is computed for both modes of the switched system. Finally, a simulation example for a case study of boost converter and a numerical example with both abrupt and incipient faults are illustrated to prove the efficacy of the proposed method.
Recently, different metaheuristic techniques, their variants, and hybrid forms have been extensively used to solve economic load dispatch (ELD) problems with and without valve point loading (VPL) effects. Due to the randomization involved in these metaheuristic techniques, one has to perform extensive runs for each experiment to get an optimal solution. The process may sometimes become laborious and time-consuming to converge to an optimal solution. On the other hand, advanced calculus-based techniques, being deterministic, perform iteration systematically and come up with the same solution on each run of the experiment. Since ELD problems are constrained optimization problems, we are proposing the constrained (deterministic) optimization algorithm for their solutions. Various 13-unit, 38-unit, and 40-unit thermal test systems are considered. Valve point loading (VPL) effects are also considered in some cases. Computer-based numerical results depict that the constrained optimization algorithm shows evidence of being almost as competitive in a total fuel cost as the metaheuristic optimization techniques, especially for the less-constrained ELD problems but with far reduced computation time. This finding validates the application of the constrained optimization technique to solve the economic dispatch problem.
19 March 2020 in Arabian Journal for Science and Engineering
The problem of voltage sag and swell is one of the major reasons for low-quality power in the distribution system. Normally, it results from the system’s faults, including line-to-ground and line-to-line, non-linear characteristics of loads and sources. Its effect is very serious for the critical loads as their performance is very sensitive to the variation in voltage. The stabilization of voltage is a mandatory requirement in such a situation. The correction of such problems requires the addition and subtraction of the voltage once the line voltage is decreased and increased. This behavior of the correcting voltage is ensured by the use of voltage controllers that can convert a constant input voltage into a non-inverted and inverted variable form. Their voltage gains depend on the depth level of the problem. The voltage buck and boost capabilities of the AC voltage stabilizers can tackle the problems having any depth level. The smartness of such a system depends on the number of electronic devices as they are the key elements in the power conversion system. Therefore, this research proposes a new AC voltage controller with fewer solid-state devices. Its overall impact is low volume and cost. The validation of the introduced approach is ensured with the help of simulation modeling and results gained from the practical setup.