Janez Trontelj

Prof. Janez Trontelj

Laboratory for Microelectronics, Faculty of Electrical Engineering, University of Ljubljana, Tržaska 25, Ljubljana, SI-1000 Ljubljana, Slovenia

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Irmantas KasalynasIrmantas Kasalynas
Irmantas Kasalynas
RVRimvydas Venckevičius
Rimvydas Venckevičius
LMLinas Minkevicius
Linas Minkevicius
ASAleksander Sesek
Aleksander Sesek
FWFaustino WAHAIA
Faustino WAHAIA
Janez TronteljJanez Trontelj
Janez Trontelj
A terahertz (THz) imaging system based on narrow band microbolometer sensors (NBMS) and a novel diffractive lens was developed for spectroscopic microscopy applications. The frequency response characteristics of the THz antenna-coupled NBMS were determined employing Fourier transform spectroscopy. The NBMS was found to be a very sensitive frequency selective sensor which was used to develop a compact all-electronic system for multispectral THz measurements. This system was successfully applied for principal components analysis of optically opaque packed samples. A thin diffractive lens with a numerical aperture of 0.62 was proposed for the reduction of system dimensions. The THz imaging system enhanced with novel optics was used to image for the first time non-neoplastic and neoplastic human colon tissues with close to wavelength-limited spatial resolution at 584 GHz frequency. The results demonstrated the new potential of compact RT THz imaging systems in the fields of spectroscopic analysis of materials and medical diagnostics.

28 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MMMatija Mraovic
Matija Mraovic
TMTadeja Muck
Tadeja Muck
MPMatej Pivar
Matej Pivar
Janez TronteljJanez Trontelj
Janez Trontelj
APAnton Pleteršek
Anton Pleteršek
Research, design, fabrication and results of various screen printed capacitive humidity sensors is presented in this paper. Two types of capacitive humidity sensors have been designed and fabricated via screen printing on recycled paper and cardboard, obtained from the regional paper and cardboard industry. As printing ink, commercially available silver nanoparticle-based conductive ink was used. A considerable amount of work has been devoted to the humidity measurement methods using paper as a dielectric material. Performances of different structures have been tested in a humidity chamber. Relative humidity in the chamber was varied in the range of 35%–80% relative humidity (RH) at a constant temperature of 23 °C. Parameters of interest were capacitance and conductance of each sensor material, as well as long term behaviour. Process reversibility has also been considered. The results obtained show a mainly logarithmic response of the paper sensors, with the only exception being cardboard-based sensors. Recycled paper-based sensors exhibit a change in value of three orders of magnitude, whereas cardboard-based sensors have a change in value of few 10s over the entire scope of relative humidity range (RH 35%–90%). Two different types of capacitor sensors have been investigated: lateral (comb) type sensors and modified, perforated flat plate type sensors. The objective of the present work was to identify the most important factors affecting the material performances with humidity, and to contribute to the development of a sensor system supported with a Radio Frequency Identification (RFID) chip directly on the material, for use in smart packaging applications. Therefore, the authors built a passive and a battery-supported wireless module based on SL900A smart sensory tag’s IC to achieve UHF-RFID functionality with data logging capability.

22 March 2012 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
Anton PletersekAnton Pletersek
Anton Pletersek
MSMiha Sok
Miha Sok
Janez TronteljJanez Trontelj
Janez Trontelj

17 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MPMatija Podhraški
Matija Podhraški
Janez TronteljJanez Trontelj
Janez Trontelj
An inductive linear displacement measurement microsystem realized as a monolithic Application-Specific Integrated Circuit (ASIC) is presented. The system comprises integrated microtransformers as sensing elements, and analog front-end electronics for signal processing and demodulation, both jointly fabricated in a conventional commercially available four-metal 350-nm CMOS process. The key novelty of the presented system is its full integration, straightforward fabrication, and ease of application, requiring no external light or magnetic field source. Such systems therefore have the possibility of substituting certain conventional position encoder types. The microtransformers are excited by an AC signal in MHz range. The displacement information is modulated into the AC signal by a metal grating scale placed over the microsystem, employing a differential measurement principle. Homodyne mixing is used for the demodulation of the scale displacement information, returned by the ASIC as a DC signal in two quadrature channels allowing the determination of linear position of the target scale. The microsystem design, simulations, and characterization are presented. Various system operating conditions such as frequency, phase, target scale material and distance have been experimentally evaluated. The best results have been achieved at 4 MHz, demonstrating a linear resolution of 20 µm with steel and copper scale, having respective sensitivities of 0.71 V/mm and 0.99 V/mm.

5 April 2019 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Closed access
PDF file
NKNatasa Koceska
Natasa Koceska
RKRadko Komadina
Radko Komadina
MSMonika Simjanoska
Monika Simjanoska
BKBojana Koteska
Bojana Koteska
ASAndrej Strahovnik
Andrej Strahovnik
Janez TronteljJanez Trontelj
Janez Trontelj

14 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LMLinas Minkevicius
Linas Minkevicius
LQLiang Qi
Liang Qi
Agnieszka SiemionAgnieszka Siemion
Agnieszka Siemion
DJDomas Jokubauskis
Domas Jokubauskis
ASAleksander Sesek
Aleksander Sesek
GVGintaras Valusis
Gintaras Valusis
Terahertz (THz) imaging and spectroscopy set-ups require fine optical alignment or precise control of spatial mode profile. We demonstrate universal, convenient and easy-to-use imaging—resonant and broadband antenna coupled ultrasensitive titanium-based—dedicated to accurately adjust and control spatial mode profiles without additional focusing optical components of weak power THz sources. Versatile operation of the devices is shown using different kinds of THz—electronic multiplier sources, optical THz mixer-based frequency domain and femtosecond optoelectronic THz time-domain spectrometers as well as optically pumped molecular THz laser. Features of the microbolometers within 0.15–0.6 THz range are exposed and discussed, their ability to detect spatial mode profiles beyond the antennas resonances, up to 2.52 THz, are explored. Polarization-sensitive mode control possibilities are examined in details. The suitability of the resonant antenna-coupled microbolometers to resolve low-absorbing objects at 0.3 THz is revealed via direct, dark field and phase contrast imaging techniques as well.