The heterodyne interferometer is widely used as a precise displacement sensor in ultraprecision processing. However, there is a trade-off between measurement speed and measurement precision in the existing interference signal processing methods. In this work, a novel phase measurement method based on digital dual frequency comb is proposed. The proposed method uses the intrinsic frequency comb signal and a narrowband low-pass filter to form a band-pass filter bank, which divides the broadband brought by high-speed movement into multiple narrow bands. The signal-to-noise ratio (SNR) is improved for phase calculation. In addition, two groups of intrinsic frequency comb signals are used simultaneously for phase measurement and the rotation of the output, preventing the inaccurate phase measurement of the input signal whose frequency is the average of two frequencies in the frequency comb signal. The heterodyne laser interferometer can maintain high precision at high measurement speed. The simulation results show that the precision of the proposed method is more than 50% higher than that of the phase-locked loop method. The experiment with a circuit board combined with 100 Msps sampling 16-bit A/D converter shows that the phase measurement precision of the input signal frequency in the bandwidth range of 2.5–37.5 MHz can reach 0.77 mrad, equivalent to the displacement measurement precision of the double-pass interferometer (19 pm) at a measurement speed of less than 2.77 m/s.
Heterodyne interferometry is playing an increasingly important role in the field of high-end equipment manufacturing. In photolithography, the precision requirement of displacement metrology is increasing to a deep sub-nanometer scale with the decrease in the critical dimension of chips. The error caused by light intensity changes was investigated, and its principle was found to be related to the time difference in photoelectric conversion. On the basis of the analysis of dynamic characteristics of interference light intensity changes in a heterodyne Michaelson interferometer, the influencing factors, and the features of the measurement error, equivalent measurement and real-time compensation methods were investigated and proposed. Experiments revealed that the error was 220 pm using the method of best-gain detection, while it was 4.8 nm using the method of auto-gain detection over a wide dynamic range when the light intensity was reduced by 30%. However, the proposed compensation method successfully reduced the error to less than 40 pm. Therefore, the real-time compensation method based on equivalent measurement can maintain the signal-to-noise ratio while improving the precision of photoelectric conversion, removing the error caused by intensity changes, and helping heterodyne interferometry achieve deep sub-nanometer precision.
10 October 2024 in IEEE Transactions on Instrumentation and Measurement
In the field of heterodyne interferometry, the dynamic performance of measurement electronics decisively influences the dynamic measurement capabilities of the interferometer. Existing test methodologies fail to simultaneously provide comprehensive, rapid, and precise evaluations. Thus, this research introduces an equivalent testing approach, informed by an analysis of phase, frequency, and contrast characteristics of dynamic interference signals. This method employs intensity modulation via an acoustic optical modulator, ensuring phase stability, and thus, high testing accuracy. The design incorporates beam tuners and harmonic-optimized modulation, enhancing the signal frequency range and contrast variability, thereby enabling high equivalent speed. A testing apparatus was constructed, and a series of experiments conducted. The results demonstrated the ability of the method to evaluate the dynamic performance of measurement electronics with an accuracy of 0.03 nm, within a maximum speed of 2.69 m/s and a contrast range of 10-90%. This technique outperforms other methods by improving the testing accuracy by one to two orders of magnitude, increasing the equivalent speed from static to the order of m/s, and introducing contrast evaluation.
This paper proposes a two-dimensional precision level for real-time measurement using a zoom fast Fourier transform (zoom FFT)-based decoupling algorithm that was developed and integrated in an FPGA. This algorithm solves the contradiction between obtaining high resolution and obtaining high measurement speed, and achieves both high angle-resolution measurement and real-time measurement. The proposed level adopts a silicone-oil surface as the angle-sensitive interface and combines the principle of homodyne interference. By analyzing the frequency of the interference fringes, the angle variation can be determined. The zoom-FFT-based decoupling algorithm improves the system’s frequency resolution of the interference fringes, thereby significantly enhancing the angle resolution. Furthermore, this algorithm improves the efficiency of angle decoupling, while the angle decoupling process can also be transplanted to the board to realize real-time measurement of the level. Finally, a prototype based on the level principle was tested to validate the effectiveness of the proposed method. The principle analysis and test results showed that the angle resolution of the prototype improved from 9 arcsec to about 0.1 arcsec using this angle-solution method. At the same time, the measurement repeatability of the prototype was approximately ±0.2 arcsec. In comparison with a commercial autocollimator, the angle measurement accuracy reached ±0.6 arcsec.
The wide application of displacement measurement in high-precision equipment production and high-precision metrology is placing increasing pressure on the resolution of heterodyne interferometers. However, as the core component of an interferometer, since measurement electronics includes the cross-physical process of photoelectric conversion, its resolution is rarely evaluated, either on an individual level or as a whole. Therefore, in this paper, we propose a picometer resolution test method for measurement electronics, that uses intensity modulation signals based on an AOM to replace the beat frequency interference signals, and an ordinary commercial guide rail to equivalently generate the pm-level displacement of the heterodyne interferometer under laboratory conditions. Based on the detailed analysis of the type of noise in the test device, the correlation between the light intensity and the nonlinear error was established, and nonlinearity was suppressed to 10% of the original level. Furthermore, this test method allows one to perform a 0.1 mrad phase step test at 1 MHz signal frequency, equivalent to a 2.5 pm resolution test in a double-pass heterodyne interferometer. Simultaneously, it can be directly applied to the resolution test for measurement electronics with a center frequency in the range of 1 MHz to 20 MHz.
In order to provide theoretical guidance for optimized design and operation of multiple-circuit transmission lines on the same tower, a new method for measuring the line unbalance is proposed, which characterized its physical nature. Using PSCAD, the unbalance factors of the six-circuit transmission lines on the same tower are simulated and calculated, under different line lengths and different phase sequence layouts, the influence of connection patterns of the ground wires on line unbalance are comparatively analyzed. Results show the method is applicable and convenient, accurately reflecting the property of the line unbalance; the connection pattern of ground wires is the main factor that influences zero-sequence unbalance.