Sabry Fayed

Prof. Sabry Fayed


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
SFSabry Fayed
Sabry Fayed
Mohamed GhallaMohamed Ghalla
Mohamed Ghalla
Jong Wan HuJong Wan Hu
Jong Wan Hu
EMEhab Mlybari
Ehab Mlybari
AAAbdullah Albogami
Abdullah Albogami
SYSaad A. Yehia
Saad A. Yehia
In this study, shear-critical reinforced concrete (RC) beams were strengthened by combining the prestressing and near-surface mounted (NSM) rods approaches. The potential danger of failure in such RC beams is a substantial concern as it is considered a potential threat. This study addresses its careful mitigation through experimental identification and numerical analysis to enhance the safety and sustainability of buildings by reducing the probability of failure risk for these RC beams. Nine of the ten RC beams that were tested had strengthened, and one had not. Internal prestressing (IP) within the beam body, external prestressing NSM (PNSM), internal embedment (IE) inside the beam with or without prestressing, and NSM are the strengthening technologies that were employed. The range of the extra shear reinforcement ratios (μs) was 0.87% to 1.60%. We investigated how strengthened beams behaved structurally in terms of the cracking load, ultimate load, load–deflection response, ultimate deflection, and stiffness. The insertion of five pairs of PNSM rods (μs = 1.45%) and five pairs of IP rods (μs = 1.6%), respectively, increased the beams’ shear capacity by 57.8% and 70.4%. Shear capacity increased by 23.2% when three pairs of IE rods (μs = 1.02%) were installed. The prestressing location had an impact on shear capacity, with the interior case surpassing the external one. Compared to the control, the stiffness of the strengthened beams rose by 20%, 82%, and 84.4% when three, four, or five pairs of internal prestressing rods were added. A formula is proposed to calculate the shear capacity of all beams strengthened using various methods.

26 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SFSabry Fayed
Sabry Fayed
MBMoataz Badawi
Moataz Badawi
MGMohamed Ghalla
Mohamed Ghalla
EMEhab A. Mlybari
Ehab A. Mlybari
YIYahia Iskander
Yahia Iskander
SYSaad A. Yehia
Saad A. Yehia
Three push-out specimens were experimentally tested to investigate the behavior of tubular steel columns (TSC) with and without bolted shear connectors embedded in normal concrete (NC). Each specimen consisted of a tubular steel column (TSC) encased in a 250 × 250 × 200 mm concrete cube The embedment/the prominent height of TSC was 100 mm. Foam was used underneath the TSC to form free space. The study considered variables such as the presence of demountable shear studs and reinforcement. The failure modes, load-slip response, peak load/slip, and shear stiffness of the specimens were analyzed. Furthermore, a finite element model (FEM) was developed using ABAQUS software to simulate the behavior of the tested specimens and validated against the experimental results. The FEM was also employed to conduct further parametric investigations. The results indicate that demountable shear studs significantly improve shear capacity, with specimens exhibiting a 217% higher peak load than those without studs. Reinforcing the concrete block had a negligible effect on peak load but increased peak slip by 37.7% and shear stiffness by 18.7% compared to the unreinforced specimen. Furthermore, increasing the TSC thickness significantly enhances peak load, with a 154.31% increase observed as the thickness increases from one-third of the bolt diameter to the full bolt diameter. Additionally, using TSC thicknesses greater than half the bolt diameter helps prevent bearing failure. Increasing the concrete compressive strength from 25 to 50 MPa leads to a 24.6% increase in peak load, while slip capacity decreases by 19.77%. For applications requiring high ductility, excessively high-strength concrete should be avoided, as it reduces slip capacity. The results also demonstrate that the bolt diameter should not exceed twice the TSC web thickness to prevent bearing failure.

11 October 2024 in Materials
Verified
Journal Article
Open access
PDF file
AEAli Serdar ECEMIS
Ali Serdar ECEMIS
EMRAH MADENCİEMRAH MADENCİ
EMRAH MADENCİ
MKMemduh Karalar
Memduh Karalar
SFSabry Fayed
Sabry Fayed
EAEssam Althaqafi
Essam Althaqafi
Yasin OzkilicYasin Ozkilic
Yasin Ozkilic
An investigation was conducted to assess the efficacy of using waste rubber as a substitute for a portion of an aggregate to enhance concrete’s sustainability. For the purpose of accomplishing this objective, a total of 12 specimens were constructed and then subjected to a series of tests to investigate their bending behavior. The samples were constructed with the following dimensions: 1000 mm length and a 100 mm by 150 mm cross-sectional area. A few factors were selected, including the impacts of the longitudinal reinforcement ratio and the waste rubber ratio. Based on the volume of aggregates, rubber replacement rates of 0%, 5%, 10%, and 15% were investigated in this study. To assess the beam bending behavior, the stirrup width and spacing were kept constant at ∅6/10. The longitudinal reinforcement was composed of three diameters: ∅6 at the top (for all beams) and ∅8, ∅10, and ∅12 at the bottom. The experimental results demonstrated that the effects of varying amounts of waste rubber and tension reinforcement on the bending and cracking of reinforced concrete beams (RCBs) were varied. The findings indicate that the incorporation of waste rubber into concrete results in a reduction in both the load-carrying capacity and the level of deformation of the material. Additionally, it was shown that as the amount of waste rubber in the RCB increased, the energy absorption capacity and ultimate load decreased. There was a reduction in energy dissipation of 53.71%, 51.69%, and 40.55% for ∅8 when longitudinal reinforcement was applied at 5%, 10%, and 15% replacement, respectively. Additionally, there were reductions of 25.35%, 9.31%, and 58.15% for ∅10, and 38.69%, 57.79%, and 62.44% for ∅12, respectively.

9 September 2020 in Structural Concrete
Verified
Journal Article
Closed access
PDF file
SFSabry Fayed
Sabry Fayed
ABAli Basha
Ali Basha
GEGalal Elsamak
Galal Elsamak

28 March 2023 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
YSYousry B Shaheen
Yousry B Shaheen
BEBoshra Eltaly
Boshra Eltaly
SYShaimaa G. Yousef
Shaimaa G. Yousef
SFSabry Fayed
Sabry Fayed
In this study, 10 ferroconcrete concrete (FC) beams with lightweight cores reinforced with welded steel mesh as a shear reinforcement were evaluated under three-point bending tests along with two conventionally normal-weight concrete (NWC) beams. Expanded polystyrene and lightweight aerated autoclaved brick wastes were used to create lightweight core concrete. The main factors include the type of lightweight concrete used for the core, beam concrete type, the form and number of holes, the existing steel mesh fabric, the hollow, and the hole placement. This study was done on the tested beams' ductility index, failure modes, first cracking loads and associated deflections, and ultimate loads besides corresponding deflections. Experimental results showed that the use of FC, various filling materials, and welded steel meshes in place of traditional stirrups enhanced the ultimate load by 36.6–107.3%, the ultimate deflection by 6–272%, and the ductility by 89–1155% when referenced to a control NWC beam. When the holing ratio increased from 10 to 20%, the ductility of FC beams was enhanced by 307.7%. Proposed equations were developed to predict the ultimate load and bending moment capacity of FC beams while taking into account the compressive strength of the beam body and filling material, the holing ratio, the tensile reinforcement ratio, and the volume fraction of the steel mesh.

1 November 2023 in Arabian Journal for Science and Engineering
Verified
Journal Article
Open access
PDF file
SFSabry Fayed
Sabry Fayed
EMEmrah Madenci
Emrah Madenci
YÖYasin Onuralp Özkiliç
Yasin Onuralp Özkiliç
TTTaher A. Tawfik
Taher A. Tawfik
For the safe transmission of loads to concrete supports, such as column-foundations, corbels, bridge pedestals, post-tension members, support anchorages, and other forms of superstructure supports, the concrete bearing strength is considered an essential design parameter. The usage of recycled aggregate within concrete is considered environmentally friendly since it diverts rubbish from bulldozing and preserves natural resources. End-hooked steel fibre is an almost substantial enhancer for recycled aggregate concrete characteristics. Never before has the bearing behavior of recycled aggregate concrete been evaluated. Thus, this study provides an experimental evaluation of the bearing strength of steel fiber-reinforced recycled aggregate concrete at different replacement levels (0, 10, 20, 30, 50, and 100%) of recycled concrete aggregate (RCA). The used fraction quantities of steel fiber were 0.5%, 1.5%, and 2%. Three sizes of blocks were manufactured (100 × 100 × 100 mm, 150 × 150 × 150 mm, and 250 × 250 × 250 mm). The ratio of concrete block area to bearing area (A2/A1) was kept constant at 2.5 for all three block sizes. The primary purpose of this research was to examine the impact of block size on bearing stiffness, ultimate slip, and ultimate bearing strength. The findings demonstrated that the bearing stiffness and bearing strength reduced as the block size increased. To assess the ultimate bearing stiffness/strength and normalised ultimate bearing slip, analytical models were employed to develop new proposed equations that unaccounted for the impact of compressive strength, RCA, reinforcing index of steel fibre, and block size. In addition, this research led to the creation of a modified ACI 318 formula that accurately forecasts the bearing strength of concrete depending on block size.