John Saffell

Dr. John Saffell

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in Applied Spectroscopy Reviews
Verified
Journal Article
Open access
MGMILA RÓDENAS GARCÍA
MILA RÓDENAS GARCÍA
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
Pedro BrancoPedro Branco
Pedro Branco
Francesca BorghiFrancesca Borghi
Francesca Borghi
GVGuillermo Villena
Guillermo Villena
Sofia SousaSofia Sousa
Sofia Sousa
Humans spend the majority of their time indoors, where they are potentially exposed to hazardous pollutants. Within this context, over the past few years, there has been an upsurge of low-cost sensors (LCS) for the measurement of indoor air pollutants, motivated both by recent technological advances and by increased awareness of indoor air quality (IAQ) and its potential negative health impacts. Although not meeting the performance requirements for reference regulatory-equivalent monitoring indoors, LCS can provide informative measurements, offering an opportunity for high-resolution monitoring, emission source identification, exposure mitigation and managing IAQ and energy efficiency, among others. This article discusses the strengths and limitations that LCS offer for applications in the field of IAQ monitoring; it provides an overview of existing sensor technologies and gives recommendations for different indoor applications, considering their performance in the complex indoor environment and discussing future trends.

31 July 2024 in Environmental Research
Verified
Journal Article
Open access
Pedro BrancoPedro Branco
Pedro Branco
Sofia SousaSofia Sousa
Sofia Sousa
MDMarzena Roza Dudzińska
Marzena Roza Dudzińska
DRDuygu Gazioglu Ruzgar
Duygu Gazioglu Ruzgar
MMMustafa Mutlu
Mustafa Mutlu
AWAnnemarie Weersink
Annemarie Weersink
Indoor air quality (IAQ) in educational facilities is crucial due to the extended time students spend in those environments, affecting their health, academic performance, and attendance. This paper aimed to review relevant parameters (building characteristics and factors related with occupancy and activities) for assessing IAQ in educational facilities, and to identify the parameters to consider when performing an IAQ monitoring campaign in schools. It also intended to identify literature gaps and suggest future research directions. A narrative literature review was conducted, focusing on seven key parameters: building location, layout and construction materials, ventilation and air cleaning systems, finishing materials, occupant demographics, occupancy, and activities. The findings revealed that carbon dioxide (CO2) levels were predominantly influenced by classroom occupancy and ventilation rates, while particulate matter (PM) concentrations were significantly influenced by the building's location, design, and occupant activities. Furthermore, this review highlighted the presence of other pollutants, such as trace metals, polycyclic aromatic hydrocarbons (PAHs), carbon monoxide (CO), nitrogen dioxide (NO2), ozone (O3), and radon, linking them to specific factors within the school environment. Different IAQ patterns, and consequently different parameters, were observed in various school areas, including classrooms, canteens, gymnasiums, computer rooms, and laboratories. While substantial literature exists on IAQ in schools, significant gaps still remain. This study highlighted the need for more studies in middle and high schools, as well as in other indoor microenvironments within educational settings beyond classrooms. Additionally, it underscored the need for comprehensive exposure assessments, long-term studies, and the impacts of new materials on IAQ including the effects of secondary reactions on surfaces. Seasonal variations and the implications of emerging technologies were also identified as requiring further investigation. Addressing those gaps through targeted research and considering the most updated standards and guidelines for IAQ, could lead to define more effective strategies for improving IAQ and safeguarding the students' health and performance.

3 July 2023 in Standards
Verified
Journal Article
Open access
PDF file
JSJohn Saffell
John Saffell
Sascha NehrSascha Nehr
Sascha Nehr
Human beings experience a large fraction of their exposure to air pollutants in indoor environments. Air pollution is a large environmental health risk, and exposure to ambient air pollution and indoor air pollution contribute equally to the total number of fatalities worldwide. Although legislative authorities have established limit values for ambient outdoor air and stack emissions, there are inconsistent and variable national and regional limit values for gaseous substances and airborne particulate matter in the built environment (schools, homes, healthcare facilities, offices, and other public spaces). This lack of regulation is unsurprising, because indoor spaces are characterized by complex air chemistry, and their construction materials and types of activities vary significantly. The current understanding of indoor pollutants, including short-lived oxidants, degradation of VOCs, particle formation, and particle composition, is incomplete. It is necessary to identify and assess emerging pollutants and their toxicity, and to consider new consumer products and green construction materials and their impact on indoor air quality (IAQ). Learning from IAQ surveys and audit protocols, research methodologies should be regularized for cross-research comparisons. Some indoor air quality guidance and standards have been written, and several more are in development, with the international ISO 16000 series of indoor standards leading the way for improving indoor air data quality. The WHO has established some ambient air limit values which can mostly be translated into indoor limit values. The built environment needs to harmonize energy efficiency, thermal comfort and air quality standards and guidance. In this review, we discuss the next steps for improving international, regional and national standards and guidance, leading to better and more complete indoor air quality regulations.

12 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Sérgio Ivan LopesSérgio Ivan Lopes
Sérgio Ivan Lopes
COCezary Orłowski
Cezary Orłowski
Pedro BrancoPedro Branco
Pedro Branco
Kostas KaratzasKostas Karatzas
Kostas Karatzas
GVGuillermo Villena
Guillermo Villena
MGMILA RÓDENAS GARCÍA
MILA RÓDENAS GARCÍA
In recent decades, significant efforts have been devoted to constructing energy-efficient buildings, providing comfortable indoor environments. However, measures such as enhanced airtightness, while reducing infiltration through the building envelope, might consequently reduce natural ventilation. This reduction is a critical concern because natural ventilation is an essential factor in controlling indoor air quality (IAQ), and its diminution could therefore worsen IAQ. Sick building syndrome has emerged as a term used to describe health hazards linked to the time spent indoors but with no particular cause. Since people spend most of their time indoors, the demand for continuous and real-time IAQ management to reduce human exposure to pollutants has increased considerably. In this context, low-cost sensors (LCS) for IAQ monitoring have become popular, driven by recent technological advancements and increased awareness regarding indoor air pollution and its negative health impacts. Although LCS do not meet the performance requirements of reference and regulatory equipment, they provide informative measurements, offering high-resolution monitoring, emission source identification, exposure mitigation, real-time IAQ assessment, and energy efficiency management. This perspective article proposes a general model for LCS systems (and subsystems) implementation and presents a prospective analysis of their strengths and limitations for IAQ management, reviews the literature regarding sensor system technologies, and offers design recommendations. It provides valuable insights for researchers and practitioners in the field of IAQ and discusses future trends.

18 October 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
PZPengfei Zhou
Pengfei Zhou
JTJone-Him Tsang
Jone-Him Tsang
Chris BlackmanChris Blackman
Chris Blackman
Yanbai ShenYanbai Shen
Yanbai Shen
JLJinsheng Liang
Jinsheng Liang
EDEhsan Danesh
Ehsan Danesh
Gas sensors based on metal oxide semiconductors (MOS) have been widely used for the detection and monitoring of flammable and toxic gases. In this paper, p-type Cr2O3 and Ti-doped Cr2O3 (CTO) thin films were synthesized using an aerosol-assisted chemical vapor deposition (AACVD) method. Detailed analysis of the thin films deposited, including structural information, their elemental composition, oxidation state, and morphology, was investigated using XRD, Raman analysis, SEM, and XPS. All the gas sensors based on pristine Cr2O3 and CTO exhibited a reversible response and good sensitivity to isobutylene (C4H8) and ammonia (NH3) gases. Doping Ti into the Cr2O3 lattice improves the response of the CTO-based sensors to C4H8 and NH3. We describe a novel mechanism for the gas sensitivity of p-type metal oxides based on variations in the oxygen vacancy concentration.

29 January 2024 in Journal of Testing and Evaluation
Verified
Journal Article
Closed access
PDF file
JSJohn Saffell
John Saffell
NMNicholas A. Martin
Nicholas A. Martin
Electrochemical amperometric gas cells are becoming the sensor of choice when measuring polluting gases using low-cost air quality networks. A number of technical issues remain to be resolved to deliver fit-for-purpose monitoring systems: humidity corrections are needed but not well understood, interfering gases such as ozone can have variable cross-sensitivity and calibration intervals, and procedures are still being investigated. Another unanswered question is the limit of detection (LOD) for electrochemical gas sensors. Estimates range from hundreds of equivalent parts per billion (ppbv) to single-digit ppbv concentrations. We discuss the LOD for nitrogen dioxide (NO2), an important gas when monitoring air quality. Multiple NO2 sensor systems were tested in an environmental chamber to determine, among other parameters, the LOD for NO2 electrochemical gas sensors. Low-noise electronics and battery powering further reduced electronic noise, allowing the intrinsic LOD of the electrochemical cell to be determined. Noise, quantified as the standard deviation in zero air in a very stable temperature and relative humidity–controlled chamber was <500 pA, which translated into 1.6 ppbv, so the LOD, 3 × standard deviation, was 4.8 ppb. Interestingly, the LOD calculated with 300 ppbv NO2 test gas was the same (±0.1 ppbv). Further tests with a higher resolution analog-to-digital converter resulted in the same LOD, further leading to the conclusion that for the Alphasense NO2-A43F NO2 sensor, the limiting value for LOD is 4.8 ppbv.