We present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized recording pixels (20 µm × 20 µm) and 12 reference pixels (20 µm × 80 µm), densely packed on a 50 µm thick, 100 µm wide, and 8 mm long shank. The active electrodes or pixels consist of dedicated in-situ circuits for signal source amplification, which are directly located under each electrode. The probe supports the simultaneous recording of all 1356 electrodes with sufficient signal to noise ratio for typical neuroscience applications. For enhanced performance, further noise reduction can be achieved while using half of the electrodes (678). Both of these numbers considerably surpass the state-of-the art active neural probes in both electrode count and number of recording channels. The measured input referred noise in the action potential band is 12.4 µVrms, while using 678 electrodes, with just 3 µW power dissipation per pixel and 45 µW per read-out channel (including data transmission).
28 March 2018 in Journal of Micromechanics and Microengineering
This paper presents a fast analytical procedure in order to design a micro-opto-mechanical pressure sensor (MOMPS) taking into account the mechanical nonlinearity and the optical losses. A realistic model of the photonic MZI is proposed, strongly coupled to a nonlinear mechanical model of the membrane. Based on the membrane dimensions, the residual stress, the position of the waveguide, the optical wavelength and the phase variation due to the opto-mechanical coupling, we derive an analytical model which allows us to predict the response of the total system. The effect of the nonlinearity and the losses on the total performance are carefully studied and measurements on fabricated devices are used to validate the model. Finally, a design procedure is proposed in order to realize fast design of this new type of pressure sensor.
The motivation of this work is to enable the use of piezoelectric micromachined ultrasonic transducer (PMUT)-based implants within the human body for biomedical applications, particularly for power and data transfer for implanted medical devices. To protect surrounding tissue and ensure PMUT functionality over time, biocompatible and hermetic encapsulation is essential. This study investigates the impact of Parylene F-VT4 layers of various thicknesses as well as the effect of multilayer stacks of Parylene F-VT4 combined with atomic layer-deposited nanolayers of Al2O3 and HfO2 on the mechanical and acoustic properties of PMUTs. PMUTs with various diameters (40 µm, 60 µm, and 80 µm) are fabricated and tested both as stand-alone devices and as arrays. The mechanical behavior of single stand-alone PMUT devices is characterized in air and in water using laser Doppler vibrometry (LDV), while the acoustic output of arrays is evaluated by pressure measurements in water. Experimental results reveal a non-monotonic change in resonance frequency as a function of increasing encapsulation thickness due to the competing effects of added mass and increased stiffness. The performance of PMUT arrays is clearly influenced by the encapsulation. For certain array designs, the encapsulation significantly improved the arrays’ pressure output, a change that is attributed to the change in the acoustic wavelength and inter-element coupling. These findings highlight the impact of encapsulation in modifying and potentially enhancing PMUT performance.
As smart structures are becoming increasingly ubiquitous in our daily life, the need for efficient modeling electromechanical coupling devices is also rapidly advancing. Smart structures are often made of piezoelectric materials such as lead zirconate titanate (PZT), which exhibits strong nonlinear behavior known as hysteresis effect under a large applied electric field. There have been numerous modeling techniques that are able to capture such an effect; some techniques are suitable for obtaining physical insights into the micro-structure of the material, while other techniques are better-suited to practical structural analyses. In this paper, we aim to achieve the latter. We propose a simplified phenomenological macroscopic model of a nonlinear ferroelectric actuator. The assumption is based on the direct relation between the irreversible strain and irreversible electric field, and the consequently irreversible polarization. The proposed model is then implemented in a finite element framework, in which the main features such as local return mapping and the tangent moduli are derived. The outcomes of the model are compared and validated with experimental data. Therefore, the development presented in this paper can be a useful tool for the modeling of nonlinear ferroelectric actuators.
The pull-in and pull-out voltages are important characteristics of Capacitive Micromachined Ultrasound Transducers (CMUTs), marking the transition between conventional and collapse operation regimes. These voltages are commonly determined using capacitance–voltage (C-V) sweeps. By modeling the operating conditions of an LCR meter in COMSOL Multiphysics®, we demonstrate that the measured capacitance comprises both static and dynamic capacitances, with the dynamic capacitance causing the appearance of a peak in the effective C-V curve. Furthermore, Laser Doppler Vibrometer (LDV) measurements and electromechanical simulations indicate the occurrence of collapse–snapback phenomena during the C-V sweeps. This study, through advanced simulations and experimental analyses, demonstrates that the transient membrane behavior significantly affects the apparent capacitance–voltage characteristics of electrostatically actuated Micro-Electromechanical Systems (MEMS).
This work investigates and compares the response of piezoelectrically actuated nonlinear microelectromechanical devices (MEMS) to direct and to degenerate parametric drives. We describe the regime of degenerate parametric amplification in piezoelectric Duffing-type nonlinear MEMS devices using a single mode expansion, and we then explore the existence of regions in parameter space where parametric excitation may be advantageous compared to direct drive, which we label “parametric advantage.” Analytical, experimental, and numerical verification demonstrates that parametric advantage cannot exist if both pump and signal voltages are accounted for in the total voltage budget. This work determines non-dimensional scaling rules that can act as guidelines for selecting an optimal operating regime for degenerate parametric amplification.