Power quality (PQ) becomes a more and more pressing issue for the operation stability of power systems with renewable energy sources. An important aspect of PQ monitoring of distribution networks is to compare the PQ indicators in different operating conditions. This paper evaluates the impact of a microgrid implementation in a real distribution network on power quality indicators at the point of common coupling in an LV network. The study includes a classical assessment of the long-term PQ parameters according to the EN 50160 standard, such as nominal frequency deviations, voltage RMS variations, voltage fluctuations (represented by long-term flicker severity), voltage unbalance and total harmonic distortion. The PQ evaluation is extended in statistical assessment based on cluster analysis. The case study contains 5 weeks of power quality observation results obtained at the assessment point in two different working conditions of the distribution system: before and after implementing the microgrid. The study allows establishing general conclusions regarding a microgrid interconnection in order not to exceed power quality limits and considering the influence of photovoltaic generation on power quality parameters.
The paper presents the results of an experimental study of 26 brand new photovoltaic (PV) inverters widely available for sale on the EU market; the study was conducted in 2021 by researchers at the AGH University of Science and Technology and Tauron Dystrybucja (Polish DSO). The purpose of the study was to compare and assess PV inverter performances in terms of their DC/AC conversion efficiencies, MPPT efficiencies, and harmonic current emissions. To examine the PV inverters, a laboratory test stand was prepared according to the standard EN 50530 and the technical report IEC/TR 61000-3-15. It was composed of a photovoltaic array simulator, a programmable regenerative AC voltage source, and a power analyzer. Each PV inverter was tested in various operating states determined by the DC voltage levels and the volume of active power generation. The results allowed for a benchmark assessment of PV inverters available on the market. The results showed how various energy efficiency indicators of individual PV inverters changed depending on their operating points. The results also revealed that, based on the performed harmonic emission tests, individual harmonics were within the normative requirements; however, in the case of several PV inverters, attention was drawn to the presence of relatively high switching frequency-related components exceeding permissible levels.
In recent years, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Polish Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from dispersed electricity meters to locate dominant sources of disturbances in the power network of the Polish distribution system operator – TAURON Dystrybucja S.A.
The paper presents the results of an experimental study, which was conducted in 2021 and briefly presented at the conference CIGRE Paris Session 2022, as a part of a joint initiative for comparative studies of PV inverters, of AGH University of Science and Technology and Tauron Dystrybucja (Polish DSO). The study was performed on a representative sample of 29 brand new PV inverters, widely available for sale in the EU, from over 20 various manufacturers from and outside the EU. For the purposes of this research, all tested PV have been made available by their manufacturers or regional distributors, which confirms the origin of the devices from official distribution channels and their designation for the EU market. The conducted research covers the technical aspects of PV inverters’ operation and performance included in the NC RfG network code, technical standard EN-505049-1:2019, and internal regulations of distribution system operators governing PV inverter technical quality and its cooperation with the low-voltage distribution network. The national regulations may differ between individual EU member states. The paper describes the testing procedure, obtained results, conclusions, and recommendations for regulatory bodies and DSOs.
23 March 2024 in International Journal of Electronics and Telecommunications
The paper presents the propagation assessment and power quality parameters improvement system in power distribution grid. In this work main functionalities of the system are described focusing on the individual assessment module. The module is using CIRED/CIGRE C4.109 method which is based on the 10-minutes aggregated data. Three cases of individual emission assessment using real measurement data in the distribution system operator environment ware analyzed. The obtained results confirmed the legitimacy of using 10-minute data to assess the emissions of harmonics.
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.