The construction industry of Ukraine has a number of problems and barriers that hinder its development. The main problems affecting Ukraine are corruption, high level of opacity, inefficient use of resources and inefficient process management. Moreover, ineffective design and construction management reduce labor productivity and leads to reworks. Unfortunately, in Ukrainian construction industry most cases of rework have been accepted as a part of construction activities. Rework is one of the main factors in the growth of total costs and the excess of the schedule for the construction project. The problem of rework costs is important and needs to be studied more to alleviate these overruns in the future. However, rework data are usually quite difficult to obtain and most studies have been conducted in developed countries. It can be assumed that there is a greater probability of reworks and rework costs in developing countries than in the developed ones. Thus, the purpose of this article was to determine and systematize reworks factors, quantify amount of direct rework costs, determine the relationship between actual project costs, project duration variation and rework costs.
CO2 emission limits introduced by the European Union are encouraging works on new-generation materials with reduced clinker content. Currently, fumed silica from hard coal combustion is used in cement and concrete technology in Europe and Poland. Its wide application depends mainly on its chemical and phase composition, especially the reactivity of pozzolanic acids and its high fineness similar to cement Many authors studied the influence of fly ashes from hard coal combustion, in accordance with PN-EN 450-1 and 450-2, on the properties of concrete, including the course of the carbonation process. There are no studies in the literature involving ashes from sewage sludge. The objective of the research is to assess the course of carbonation of concrete produced on the basis of fly ash from the thermal transformation of sewage sludge over time and to describe this phenomenon in a mathematical form. An additional objective was to analyze the physicochemical composition of sludge ash in accordance with the requirements of EN 450-1, ASTM-C618-03. In addition, this study also demonstrated the possibility of producing fly ash-modified standard concrete through the thermal treatment of sewage sludge. The average compressive strengths of Krakow gray concrete after curing for 28, 56, 90, and 365 days were 50.1 MPa, 50.6 MPa, 50.8 MPa, and 61.9 MPa, respectively. On the one hand, the additives introduced in the concrete mixture accelerate the carbonation process by shifting the carbonation front deep into the concrete and, on the other hand, create a denser microstructure In all cases, the largest increase in carbonation depth was observed up to the 56th day of the study, while the smallest increase was observed between 90 and 180 days. The diffusivity decreases and the rate of carbonation is reduced. The determined regression coefficients of hyperbolic models indicate the proper adjustment of the adopted hyperbolic model to the results of laboratory tests under accelerated carbonation conditions (R = 0.85–0.99), regardless of the content of fly ash from sewage sludge in ordinary concrete samples.
Implementing rain garden (RG) designs is widespread worldwide to reduce peak flow rates, promote stormwater infiltration, and treat pollutants. However, inadequate RG design degrades its hydrological behaviour, requiring the development and validation of an appropriate hydrological model for the design and analysis of structures. This study aimed to improve a hydrological infiltration model based on Darcy’s law by taking into account the height of the water column (HWC) at the surface of the RG and the filtration coefficients of soil materials. The model was tested by simulating the hydrological characteristics of a rain garden based on a single rain event of critical intensity (36 mm/h). Using the validated model, design curves were obtained that predict the performance of the RG as a function of the main design parameters of the structure: water column height, ratio of catchment area to structure area, layer thickness, and soil filtration coefficient. The hydrological efficiency of the RG was evaluated in terms of the time of complete saturation, filling of the structure with water, and determining the change in HWC caused by changes in the parameters. The filtration coefficient and thickness of the upper and intermediate infiltration layers of the RG are the main parameters that affect the depth of saturation of the layers of the structure and the HWC on the surface. The model is not very sensitive to the model parameters related to the lower gravel layer. If the top layer’s thickness increases by 10 cm, it takes longer to fill the structure with water, and the HWC on the surface reaches 0.341 m. The rain garden’s performance improves when the filtration coefficient of the top layer is 7.0 cm/h. Complete saturation and filling of the structure with rainwater do not occur within 7200 s, and the water column reaches a height of 0.342 m at this filtration coefficient. However, the rain garden’s effectiveness decreases if the filtration coefficient of the upper and intermediate layers exceeds 15 cm/h and 25 cm/h, respectively, or if the catchment area to RG area ratio decreases to values below 15. The modelling results confirm that considering the HWC in RG hydrological models is essential for designing structures to minimise the risk of overflow during intense rainfall events.
This paper examines the effectiveness of sustainable warehouse design with regard to fire regulations and costs. When designing industrial facilities, the high risk of fire during their subsequent operation must be considered. Therefore, in this article, the variant analysis in terms of cost and technological, sustainable solutions for the investment in the “design and build” system were subjected to fire protection installation systems for three variants with different fire zones. During the modelling, the impact of the fire zone on the spread of smoke, temperature changes at a selected point above the fire source, and visibility were examined. Numerical analyses showed differences in the degree of smoke spread for variants I, II, and III without any relevant impact on the effectiveness of evacuation. The division of the hall into a larger number of fire zones reduces the effects of a potential fire. This study highlights that the cost of the investment is vastly influenced by the conditions of fire protection and evacuation.