José Luiz Rangel Paes

Dr. José Luiz Rangel Paes


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2024 in Structures
Verified
Journal Article
Closed access
JEJean Antonio Emerick
Jean Antonio Emerick
Humberto VarumHumberto Varum
Humberto Varum
Xavier RomãoXavier Romão
Xavier Romão
Gustavo de Souza VeríssimoGustavo de Souza Veríssimo
Gustavo de Souza Veríssimo
JPJosé Luiz Rangel Paes
José Luiz Rangel Paes

30 April 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RPRita Cláudia Jorge Peres
Rita Cláudia Jorge Peres
JCJosé Carvalho
José Carvalho
JEJean Antonio Emerick
Jean Antonio Emerick
LMLuís Macedo
Luís Macedo
JPJosé Luiz Rangel Paes
José Luiz Rangel Paes
José Miguel CastroJosé Miguel Castro
José Miguel Castro
The absence of analytical expressions in current codes for evaluating the critical moment for lateral–torsional buckling of cold-formed beams with omega-shaped sections presents a fundamental challenge when assessing their resistance to global buckling. In response to this challenge, a comparative study was conducted to explore various approaches for calculating the critical moment. This involved both analytical and numerical analyses, using different methods available in codes and computational tools. The analytical analysis followed the Effective Width Method, employing the expression proposed in ENV 1993-1-1:1992, which is commonly used for evaluating the critical lateral–torsional moment of hot-rolled profiles. Numerical analyses were then performed using the ABAQUS v6.13, GBTUL v2.0, and CUFSM v5.05 software packages. The ABAQUS model, validated with results obtained from an experimental campaign, serves as the reference model. Upon assessing the bending moment resistances according to European, Brazilian, and American standards, consistency was found among these standards. However, it became evident that using the analytical expression proposed for hot-rolled profiles is inadequate for evaluating the critical lateral–torsional moment of CFS omega-shaped profiles. Conversely, the agreement between the ABAQUS, GBTUL, and CUFSM results suggests their utility as reliable tools for estimating the elastic critical lateral–torsional buckling moment.

22 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ACAlex Bhering Cardoso
Alex Bhering Cardoso
RFRayane Neves Franco
Rayane Neves Franco
MSMariana Araújo dos Santos
Mariana Araújo dos Santos
LSLorena de Melo Sathler
Lorena de Melo Sathler
LPLeonardo Gonçalves Pedroti
Leonardo Gonçalves Pedroti
JPJosé Luiz Rangel Paes
José Luiz Rangel Paes
Steel buildings often experience failure at the interfaces between their vertical exterior enclosure systems (VEESs) and structural elements. This phenomenon generates various pathological manifestations in steel buildings, resulting in the precocious decay of the structure and the diminishment of its service life. The treatment of these interfaces is essential for ensuring their proper performance and watertightness, and to protect the durability of the steel structure. This paper proposes a method for treating common interface joints between masonry and steel structures with the application of an EPDM (ethylene propylene diene monomer) elastomer membrane. The main goal of this building technique is to ensure the durability and watertightness of the interface’s joints when they are subjected to aging triggered by heat exposure and thermal shock. The experimental models tested consisted of a steel frame and a conventional masonry vertical enclosure system with ceramic blocks plastered with cement mortar. The models were subjected to ten cycles of heat exposure and thermal shock for the purpose of simulating accelerated aging, followed by a watertightness experiment that simulated the action of both rain and wind pressure. The interfaces between masonry and the steel structure proposed in this study allowed adequate differential movements between the parts, without damage to joints and masonry. Only small cracks were observed in the outer test region of all of the interfaces tested. In the regions of the joints treated with the EPDM membrane, no alterations were visible to the naked eye. During the cycles of the heat exposure and thermal shock test, the maximum relative horizontal displacements observed in the joints were 0.743 mm for vertical joints and 0.230 mm for horizontal joints, indicating the accurate reproduction of the behavior expected from an untied interface. The results obtained in the previously mentioned watertightness test showed that no humidity stains were found on the inner face of any of the specimens, even after the continuous application of a pneumatic pressure of 400 Pa for eight hours. Therefore, the results indicated satisfactory performance in terms of durability and watertightness in all evaluated cases, indicating that the application of an EPDM membrane can be effective in preventing water leaks in the interfaces between masonry and steel elements, thus contributing to ensuring the steel structure’s durability.

24 October 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Leonardo Carvalho MesquitaLeonardo Carvalho Mesquita
Leonardo Carvalho Mesquita
MMMarília G. Marques
Marília G. Marques
JPJosé Luiz Rangel Paes
José Luiz Rangel Paes
In this study, the bending behavior of Slim-Floor beams was analyzed using FE models developed in the ABAQUS software. The validity of these models was demonstrated by comparing the numerical results obtained with experimental data found in the literature. Through parametric evaluations, the following findings were verified: (i) the connection mechanisms adopted (concrete dowels, reinforcing steel bars, and adherence) were able to activate the composite behavior between steel and concrete; (ii) the spacing between the openings, the number of openings, and the diameter of the reinforcing steel bars determine the behavior of the connection; (iii) adherence contributes little to the strength of the connection, and therefore, its contribution can be neglected; (iv) the connection mechanisms adopted in this study can promote the ductile behavior of the Slim-Floor beams.