Oľga Ivánková

Prof. Oľga Ivánková


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in Molecules
Verified
Journal Article
Open access
PDF file
JOJarmila Oremusová
Jarmila Oremusová
ZVZuzana Vitková
Zuzana Vitková
AVAnton Vitko
Anton Vitko
JOJarmila Oremusová
Jarmila Oremusová
EMEva Miklovičová
Eva Miklovičová
DKDaniel Krchňák
Daniel Krchňák
The paper analyses influences of the temperature and hydrophilic groups on micellar properties of ionic surfactants with 12-carbonic hydrophobic chains. The aim is to assess the impact of hydrophilic groups and temperature on thermodynamic parameters and micellization. This knowledge is indispensable for the formulation of new dosage forms. The method uses conductometric measurements. The following hydrophilic groups are analyzed: trimethylammonium bromide, trimethylammonium chloride, ethyldimethylammonium bromide, didodecyldimethylammonium bromide, pyridinium chloride, benzyldimethyl-ammonium chloride, methylephedrinium bromide, cis and trans-[(2-benzyloxy)-cyclohexyl-methyl]-N, N-dimethylammonium bromide, sodium sulphate and lithium sulphate. Except for a few cases, there is a good agreement between values of critical micellar concentrations (CMC) and critical vesicle concentration (CVC) obtained here and those which were obtained by other authors and/or by other physicochemical methods. Values of the CMC are compared with respect to the molar masses of hydrophilic groups. It was found that CMC values increased non-linearly with increasing system temperature. The degrees of counterion binding and thermodynamic parameters, like the standard molar Gibbs energy, enthalpy and entropy of micellization are determined and discussed in detail. The results obtained will be incorporated into in silico processes of modeling and design of optimal dosage forms, a current interdisciplinary research focus of the team.

2 September 2022 in Designs
Verified
Journal Article
Open access
PDF file
OIOľga Ivánková
Oľga Ivánková
OHOlga Hubova
Olga Hubova
MMMarek Macák
Marek Macák
EVEva Vojteková
Eva Vojteková
LKLenka Bujdáková Konečná
Lenka Bujdáková Konečná
The investigation of wind pressure distribution on a façade of an atypically shaped 162 m tall building is discussed in this paper. The horizontal cross-section was changed with the height of the structure (the square in the bottom part and the polygon in the top). The surface of the structure was smooth. A structural system was created using a combination of the tube structural system and exoskeleton structure. The building was stand-alone, located in urban terrain. In this case, the information in standards were not sufficient for its design. Therefore, other available tools had to be used for the determination of required input parameters (mean external pressure coefficients). At first, wind tunnel tests (WT) were performed on a reduced-scale model (1:300). Then, the obtained results were compared with data from a computational fluid dynamics (CFD) simulation. The accuracy of the simulation was evaluated by the method of three metrics. Short descriptions of the reduced-scale model, boundary layer wind tunnel, used measuring devices, and the methodology of tests are mentioned. The aim of this research was to identify the influence of the shape modification on the values of mean external pressure coefficients (in the comparison with the original shape, which was the cuboid). In the case of the cuboid, good agreement between the values determined by the CFD and the values from Eurocode was achieved. Larger discrepancies occurred on the roof. The modification of the total shape of the structure from the cuboid to atypical structure had the positive effect on the mean values of external pressure coefficients cpe. These values were smaller (at some levels significantly). Mainly, this effect was noticeable on the leeward side. For the wind directions 0° and 180°, the changes of the values were relatively large. For the other two wind directions (45° and 67.5°), the values on the windward sides were similar. The large advantage of this atypical structure is that the negative pressures on side walls and leeward side are smaller in the comparison with the cuboid. This is very useful for the fixing of façade components, where the values of negative pressures are larger than the positive pressures on the cladding in the larger heights.

24 October 2017 in Molecules
Verified
Journal Article
Open access
PDF file
ZVZuzana Vitkova
Zuzana Vitkova
JOJarmila Oremusová
Jarmila Oremusová
PHPetra Herdová
Petra Herdová
OIOľga Ivánková
Oľga Ivánková
AVAnton Vitko
Anton Vitko
It is known that cationic surfactants have an antimicrobial effect and act as enhancers. This paper studies three cationic surfactants from the group of alkyldimethylbenzylammonium chlorides (dodecyl-, tetradecyl-, and hexadecyl). Interest is focused on the association of the surfactants with respect to temperature, partition balances and their influence on drug release, rheological properties, and the pH of hydrogels. The critical micelle concentrations (CMC) of the surfactants were estimated from dependencies of conductivity, density, spectrofluorimetry, and UV–VIS spectrophotometry on molarity in the temperature range of 25–50 °C. It was found that the temperature dependence of a CMC is U-shaped, with its minimum at 30 °C, and the CMC value decreases as the length of the chain increases. The pseudo-phase separation model was used for the calculation of various thermodynamic parameters, such as the Gibbs free energies (spontaneous process), enthalpies (exothermic process), and entropies of the micelles’ formation, CMCs, and the degree of counterion binding. All thermodynamic parameters, as functions of the temperature, were estimated. It was found that partition coefficients increase as the length of the alkyl chain and the pH = (5.0–7.0) increase. The influences of surfactants, below and above the CMC, on drug (chlorhexidine dihydrochloride) release from hydrogels, rheological properties, and pH at 30 °C were studied. Also, the amounts of the released drug increase as the alkyl chains of the surfactants prolongate. The amounts of the released drug with the surfactant below the CMC are greater than that above the CMC. All hydrogels (regardless of the length of the alkyl chain) exhibit a non-Newtonian pseudo-plastic flow. The results obtained will be used in the formulation of the drug and surfactants into dosage forms.

10 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
OHOlga Hubova
Olga Hubova
MMMarek Macák
Marek Macák
MFMichal Franek
Michal Franek
PLPeter Lobotka
Peter Lobotka
LKLenka Bujdáková Konečná
Lenka Bujdáková Konečná
OIOľga Ivánková
Oľga Ivánková
This article deals with the investigation of wind effects on a façade of a rectangular residential building with explicit modelling of the windows for specific wind conditions. The external wind pressure coefficients were treated on the façade and at the places of the window sills, linings, and lintel for the direction of the wind from 0° to 90° with increments of 22.5°. For a detailed analysis, the CFD simulation using Ansys Fluent was used. The method selected for the CFD simulation solution and its setting (quality of meshing, horizontal homogeneity of the boundary layer, etc.) were verified by known results of similar objects. The purpose of this analysis is to show how important it is to consider wind effects to determine the suitable placement of passive ventilation devices. Research shows the potential optimal position of ventilation units in terms of favourable pressure distribution. Zones with negative pressure and corners or façades in a wake are not suitable for applying passive ventilation units. The results can serve as a basis for designers to achieve optimal comfort in residential buildings.

29 October 2023 in Buildings
Verified
Journal Article
Open access
PDF file
OHOlga Hubova
Olga Hubova
MMMarek Macák
Marek Macák
MFMichal Franek
Michal Franek
OIOľga Ivánková
Oľga Ivánková
LKLenka Bujdáková Konečná
Lenka Bujdáková Konečná
The design of a 69 m tall multipurpose building was investigated in this paper. The shape of the structure above the ground was an elliptical cylinder. Under the ground, the building was extended into a cuboid shape (for car parking). External wind pressure coefficients were determined using three methods: wind tunnel tests, CFD, and “the simplification of the shape” (using information defined in building standards). From the obtained results, it was evident that the simplification did not provide results with sufficient accuracy. The external wind pressure coefficients presented in this paper should be used for the design of a similar structure. The shape of the elliptical cylinder is very sensitive to applied wind. Positive pressures only occur on a small area of the windward side. The rest of the windward side is loaded with negative pressures. Therefore, torsional effects can occur, and these can be dangerous for the structure. The leeward side is completely loaded with negative pressures. In our case, this information was necessary for a follow-on static and dynamic analysis of the building. Various subsoil stiffness coefficients were considered. The calculated horizontal displacement was compared with the limit value. A measured wind direction of 20° caused the maximum obtained torsional moment, and a wind direction of 90° induced the maximum obtained force. The commercial program Ansys Fluent 2022 was used for the CFD simulation. The SCIA ENGINEER 21 program was used for follow-on analysis. This paper presents brief information on the selected turbulence model and details the settings used for the CFD simulation. Also, a description of the wind tunnel laboratory utilized in this study is provided, along with a description of the measuring devices used and the methodologies of the tests carried out. The main purpose of this paper is to show how important it is to consider the wind load for the static analysis of a structure like this.

17 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MTMatúš Turis
Matúš Turis
OIOľga Ivánková
Oľga Ivánková
PBPeter Burik
Peter Burik
MDMilan Držík
Milan Držík
An experimental optical method has been developed for the measurement of opening and sliding notch face movements. The light passing through a thin slit is monitored by a photodiode detector. Two parts of the slit are fixed independently on the notch faces of the simulated crack. Dynamic variations of the notch face movements are recorded as an electric signal by an oscilloscope. The sensitivity of such displacement measurement is comparable with the wavelength of light. Dynamic mixed-mode stress intensity factors under shock loading were evaluated from the data obtained and subsequently compared with a numerical simulation by ANSYS software. As it was approved, the technique has shown sufficient sensitivity, good linearity, and measurement reliability. Due to its non-destructive nature and overall robustness, the arrangement is applicable even for structural component condition determination taking into consideration potentially unknown boundary conditions and the non-linear character of mechanical parameters.