Rana Altay

Ms. Rana Altay


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Chemical Engineering Research and Design
Verified
Journal Article
Closed access
VAVahid Ebrahimpour Ahmadi
Vahid Ebrahimpour Ahmadi
İBİsmail Bütün
İsmail Bütün
RARana Altay
Rana Altay
Sajad Razavi BazazSajad Razavi Bazaz
Sajad Razavi Bazaz
HAHossein Alijani
Hossein Alijani
Ali KosarAli Kosar
Ali Kosar

3 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
RARana Altay
Rana Altay
Ali SadaghianiAli Sadaghiani
Ali Sadaghiani
MSM. Ilker Sevgen
M. Ilker Sevgen
AŞAlper Şişman
Alper Şişman
Ali KosarAli Kosar
Ali Kosar
With many emerging applications such as chemical reactions and ultrasound therapy, acoustic cavitation plays a vital role in having improved energy efficiency. For example, acoustic cavitation results in substantial enhancement in the rates of various chemical reactions. In this regard, an applied acoustic field within a medium generates acoustic streaming, where cavitation bubbles appear due to preexisting dissolved gas in the working fluid. Upon cavitation inception, bubbles can undergo subsequent growth and collapse. During the last decade, the studies on the effects of different parameters on acoustic cavitation such as applied ultrasound frequency and power have been conducted. The bubble growth and collapse mechanisms and their distribution within the medium have been classified. Yet, more research is necessary to understand the complex mechanism of multi-bubble behavior under an applied acoustic field. Various parameters affecting acoustic cavitation such as surface roughness of the acoustic generator should be investigated in more detail in this regard. In this study, single bubble lifetime, bubble size and multi-bubble dynamics were investigated by changing the applied ultrasonic field. The effect of surface roughness on bubble dynamics was presented. In the analysis, images from a high-speed camera and fast video recording techniques were used. Numerical simulations were also done to investigate the effect of acoustic field frequency on bubble dynamics. Bubble cluster behavior and required minimum bubble size to be affected by the acoustic field were obtained. Numerical results suggested that bubbles with sizes of 50 µm or more could be aligned according to the radiation potential map, whereas bubbles with sizes smaller than 10 µm were not affected by the acoustic field. Furthermore, it was empirically proven that surface roughness has a significant effect on acoustic cavitation phenomena.

11 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
RARana Altay
Rana Altay
Murat Kaya YapiciMurat Kaya Yapici
Murat Kaya Yapici
Ali KosarAli Kosar
Ali Kosar
The separation of circulating tumor cells (CTCs) from blood samples is crucial for the early diagnosis of cancer. During recent years, hybrid microfluidics platforms, consisting of both passive and active components, have been an emerging means for the label-free enrichment of circulating tumor cells due to their advantages such as multi-target cell processing with high efficiency and high sensitivity. In this study, spiral microchannels with different dimensions were coupled with surface acoustic waves (SAWs). Numerical simulations were conducted at different Reynolds numbers to analyze the performance of hybrid devices in the sorting and separation of CTCs from red blood cells (RBCs) and white blood cells (WBCs). Overall, in the first stage, the two-loop spiral microchannel structure allowed for the utilization of inertial forces for passive separation. In the second stage, SAWs were introduced to the device. Thus, five nodal pressure lines corresponding to the lateral position of the five outlets were generated. According to their physical properties, the cells were trapped and lined up on the corresponding nodal lines. The results showed that three different cell types (CTCs, RBCs, and WBCs) were successfully focused and collected from the different outlets of the microchannels by implementing the proposed multi-stage hybrid system.

22 March 2024 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
KDKendall Marie Defelippi
Kendall Marie Defelippi
AKAllyson Yuuka Saumei Kwong
Allyson Yuuka Saumei Kwong
JAJulia Rose Appleget
Julia Rose Appleget
RARana Altay
Rana Altay
MMMaya Bree Matheny
Maya Bree Matheny
MMMaryam Mobed-Miremadi
Maryam Mobed-Miremadi
A variety of hollow microneedle (HMN) designs has emerged for minimally invasive therapies and monitoring systems. In this study, a design change limiting the indentation depth of the (3D) printed custom microneedle assembly (circular array of five conical frusta with and without a stopper, aspect ratio = 1.875) fabricated using stereolithography has been experimentally validated and modeled in silico. The micro-indentation profiles generated in confined compression on 1 mm ± 0.073 mm alginate films enabled the generation of a Prony series, where displacement ranged from 100 to 250 µm. These constants were used as intrinsic properties simulating experimental ramp/release profiles. Puncture occurred on two distinct hydrogel formulations at the design depth of 150 µm and indentation rate of 0.1 mm/s characterized by a peak force of 3.5 N (H = 31 kPa) and 8.3 N (H = 36.5 kPa), respectively. Experimental and theoretical alignments for peak force trends were obtained when the printing resolution was simulated. Higher puncture force and uniformity inferred by the stopper was confirmed via microscopy and profilometry. Meanwhile, poroviscoelasticity characterization is required to distinguish mass loss vs. redistribution post-indentation through pycnometry. Results from this paper highlight the feasibility of insertion-depth control within the epidermis thickness for the first time in solid HMN literature.

23 June 2024
Verified
Conference Paper
Open access
MLMengchu Li
Mengchu Li
HGHanchen Gu
Hanchen Gu
YZYushen Zhang
Yushen Zhang
SLSiyuan Liang
Siyuan Liang
HGHudson Gasvoda
Hudson Gasvoda
USUlf Schlichtmann
Ulf Schlichtmann
Control channels on microfluidic large-scale integration (mLSI) chips are prone to blockage and leakage defects. In this work, we propose a built-in self-test (BIST) method that drastically improves the test efficiency. Given n to-be-tested control channels, we reduced the number of test patterns for blockage and leakage tests from [EQUATION] to 1, and from ⌈log2(n + 1)⌉ to ⌈log2(χ(G) + 1)⌉, respectively, where χ(G) denotes the vertex chromatic number of a graph G consisting of n vertices. We fabricated our design and demonstrated the feasibility and efficiency of our method.

28 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CACaroline Barbar Asjar
Caroline Barbar Asjar
NCNick Cmager
Nick Cmager
RARana Altay
Rana Altay
IAIsmail Emre Araci
Ismail Emre Araci
The capability to record data in passive, image-based wearable sensors can simplify data readouts and eliminate the requirement for the integration of electronic components on the skin. Here, we developed a skin-strain-actuated microfluidic pump (SAMP) that utilizes asymmetric aspect ratio channels for the recording of human activity in the fluidic domain. An analytical model describing the SAMP’s operation mechanism as a wearable microfluidic device was established. Fabrication of the SAMP was achieved using soft lithography from polydimethylsiloxane (PDMS). Benchtop experimental results and theoretical predictions were shown to be in good agreement. The SAMP was mounted on human skin and experiments conducted on volunteer subjects demonstrated the SAMP’s capability to record human activity for hundreds of cycles in the fluidic domain through the observation of a stable liquid meniscus. Proof-of-concept experiments further revealed that the SAMP could quantify a single wrist activity repetition or distinguish between three different shoulder activities.