Johannes Kunsch

Mr. Johannes Kunsch

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JWJente R. Wubs
Jente R. Wubs
UMUwe Macherius
Uwe Macherius
XLXiang Lü
Xiang Lü
LSLutz Schrottke
Lutz Schrottke
MBMatthias Budden
Matthias Budden
JHJean-Pierre van Helden
Jean-Pierre van Helden
The application of terahertz (THz) radiation in scientific research as well as in applied and commercial technology has expanded rapidly in recent years. One example is the progress in high-resolution THz spectroscopy based on quantum cascade lasers, which has enabled new observations in astronomy, atmospheric research, and plasma diagnostics. However, the lack of easy-to-use and miniaturised detectors has hampered the development of compact THz spectroscopy systems out of the laboratory environment. In this paper, we introduce a new high-speed pyroelectric receiver as a cryogen-free detector for THz absorption spectroscopy. Its performance is characterised by absorption spectroscopy measurements on a reference gas cell (RGC) with ammonia using a tunable THz quantum cascade laser at approximately 4.75 THz as the light source. It is shown that the receiver can record spectra up to 281 Hz without any artefacts to the observed spectral absorption profile, and the results reproduce the known pressure of ammonia in the RGC. This demonstrates that the pyroelectric receiver can be reliably used as an alternative to helium-cooled bolometers for absorption spectroscopy measurements in the THz range, with its main advantages being the high bandwidth, compactness, relatively low cost, and room-temperature operation. Its simplicity and high sensitivity make this receiver a key component for compact THz spectroscopy systems.

1 August 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
MHMichael Hlavatsch
Michael Hlavatsch
NSNicolas Schaefer
Nicolas Schaefer
RWRobert Weih
Robert Weih
JKJohannes Koeth
Johannes Koeth
JKJohannes Kunsch
Johannes Kunsch
BMBoris Mizaikoff
Boris Mizaikoff
In this study, we report a compact and versatile gas sensor system combining mid-infrared interband cascade light emitting diodes (MIR-ICLEDs) with substrate-integrated hollow waveguides (iHWGs) toward miniaturized gas sensors. Two readily exchangeable MIR-ICLEDs with center emission wavelengths of 3.4 µm (2941 cm−1) and 5.7 µm (1754 cm−1), respectively, were integrated into a modular sensor system using the iHWG simultaneously as a miniaturized gas cell. The performance of the sensor system for quantitative analysis was evaluated based on calibration functions established for four analytes (i.e., methane, isobutane, acetone, and acetaldehyde) within the respective spectral regions. The utility of such a sensor system as a non-dispersive infrared sensor was tested for various scenarios, including the application of spectral filters, the performance of the individual ICLEDs, and in the analysis of gas mixtures. Furthermore, we demonstrated that the modularity of the sensor design facilitates flexible adaptation to target gas species and available sample volumes, differentiating individual components within gas mixtures.

4 December 2024 in Optics Express
Verified
Journal Article
Open access
JMJakub Mnich
Jakub Mnich
JKJohannes Kunsch
Johannes Kunsch
MBMatthias Budden
Matthias Budden
TGThomas Gebert
Thomas Gebert
MSMarco Schossig
Marco Schossig
ŁSŁukasz A. Sterczewski
Łukasz A. Sterczewski
Fourier-transform infrared spectroscopy (FTIR) has matured into a versatile technique with relevance for environmental monitoring, pharmaceutical research, and food safety applications. However, compared to other spectroscopic methods, it experiences slower progress in terms of power optimization, miniaturization, and adoption by industry. To overcome this limitation, we developed an ultra-broadband room-temperature FTIR instrument relying on commercially available components that offers a spectral coverage from 1.6 µm to 31 µm (9.7–190 THz) without changing optics at a single-watt-level of electrical power consumption. To demonstrate the capabilities of the instrument, we measured atmospheric species in multiple spectral regions with better than 1.5 cm-1 resolution.

1 January 2023
Verified
Conference Paper
Closed access
PDF file
SBShankar Baliga
Shankar Baliga
JKJohannes Kunsch
Johannes Kunsch
RKReinhard Köhler
Reinhard Köhler
Pyroelectric infrared detectors are used in spectroscopy at relatively high modulation frequencies and long wavelengths out to THz. This paper describes a robust detector that provides higher performance in a scalable, disruptive sensing technology.

9 February 2026 in arXiv
Verified
Preprint
Open access
PDF file
BHBorislav Hinkov
Borislav Hinkov
JKJohannes Kunsch
Johannes Kunsch
Werner MänteleWerner Mäntele
Werner Mäntele
LSLukasz Sterczewski
Lukasz Sterczewski
ÁSÁngel Sánchez-Illana
Ángel Sánchez-Illana
HAHatice Altug
Hatice Altug
The field of infrared (IR) photonics is currently undergoing remarkable progress, moving rapidly towards practical sensing applications demanded by medical therapy and diagnostics (theranostics). The Developments can be divided into three main categories: (i) novel devices and measurement concepts including advanced updates of classical approaches that push medical sensing into the spotlight; (ii) new demonstrations of photonic integrated circuit (PIC-)based IR devices enabling highly miniaturized sensors for point-of-care application as well as medical and wellness wearables; and (iii) technologically-mature IR demonstrators that enable first medical sensing and treatment applications. This roadmap paper provides a consolidated overview of this highly dynamic and interdisciplinary research field with a focus on the major roadblocks that limit the widespread adoption of IR photonics in large-scale medical diagnostics. Special attention is given to the ambivalence between the molecular-level spectroscopic interpretation and a broader health-state assessment, highlighting the need for a common framework. Additionally, the paper discusses the critical importance of unified measurement standards, calibration protocols, and medical certification processes to ensure the validity of experimental results, reproducibility, and clinical trust, particularly when novel experimental techniques and AI algorithms are involved. Perspectives from major past and current contributors to application-oriented IR photonics will be provided.

1 January 2023
Verified
Conference Paper
Open access
PDF file
DBD. Babic
D. Babic
SBS. Baliga
S. Baliga
WPW. Pigg
W. Pigg
JRJ. Roman
J. Roman
JKJohannes Kunsch
Johannes Kunsch
RMR. Mühlenbein
R. Mühlenbein
Laser Components is a manufacturer of infrared detectors and with the mission to "Maintain and Upgrade IR Classics". PbSe polycrystalline mid-wave infrared detectors are integral part of our product portfolio. They are linear p-type photoconductors over wide bias and temperature ranges. Current flows mostly uniform across grains and connecting tissue. Photoconductivity follows the "numbers modulation" model. Practical improvement of the devices is forecasted by using sort of balanced detection scheme.