Fahui Chen

Dr. Fahui Chen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
BLBotong Li
Botong Li
FCFahui Chen
Fahui Chen
BLBin Li
Bin Li
JZJing Zhang
Jing Zhang
XJXiaotong Ji
Xiaotong Ji
QHQiteng Hong
Qiteng Hong
With the high penetration connection of inverter-interfaced distributed generators and the increasing application of large-capacity energy routers, fully weak-infeed distribution networks consisting entirely of power-electronized weak-infeed power sources are set to become one of the fundamental forms of future distribution networks. For fully weak-infeed distribution networks, multi-terminal current differential protection is considered an optional or even preferred line protection scheme. In this paper, a multi-terminal current differential protection setting method for fully weak-infeed distribution networks is proposed based on the restricted enumeration method. To address the impact of data synchronization errors and measurement errors of multi-terminal current on differential current, the problem of determining the maximum differential current superimposed with the multi-terminal current phasor errors is transformed into a high-dimensional non-convex optimization problem. The distribution law of the global optimal solution in the non-convex constraint space is deeply studied and analyzed, and a restricted enumeration method is proposed that can quickly solve the protection setting value, thereby solving the problem of multi-terminal current differential protection setting. The accuracy and rapidity of the proposed method are verified by comparing the calculation accuracy and time consumption of the restricted enumeration method and the exhaustive search. It is shown that the proposed multi-terminal differential protection setting method exhibits sufficient reliability and sensitivity in fully weak-infeed distribution networks, as verified through simulation analysis using a fully weak-infeed distribution network model built in PSCAD/EMTDC.

23 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
SSShi Su
Shi Su
QXQingyang Xie
Qingyang Xie
PMPengfei Ma
Pengfei Ma
YLYuan Li
Yuan Li
FCFahui Chen
Fahui Chen
CWChangqi Wang
Changqi Wang
Reliable fault line selection technology is crucial for preventing fault range expansion and ensuring the reliable operation of distribution networks. Modern distribution systems with neutral earthing via arc extinguishing coil face challenges during single-phase ground faults due to indistinct fault characteristics and system sequence networks influenced by the grounding methods on the distributed generation side. These factors increase the difficulty of fault line selection. By analyzing the differences between the zero-sequence currents of feeder lines and neutral lines in active distribution networks with neutral earthing via arc extinguishing coil, a method for single-phase ground fault line selection has been proposed in this paper. This method involves switching from a neutral point ungrounded mode to a low-resistance neutral grounding mode using distributed generation grid-connected transformers under permanent fault conditions. Criteria based on the differences in zero-sequence current ratios before and after the grounding mode switch are established. Simulation validation using the Power Systems Computer Aided Design (PSCAD) platform has been conducted. The proposed method demonstrates strong tolerance to transition resistance, simple extraction of fault characteristic signals, and accurate fault line selection results.

30 December 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
XHXuehao He
Xuehao He
SSShi Su
Shi Su
YLYuan Li
Yuan Li
QXQingyang Xie
Qingyang Xie
FCFahui Chen
Fahui Chen
SLSumei Liu
Sumei Liu
In line with the latest protection configuration requirements for 35 or 10 kV distribution grids, current differential protection is recommended for distribution lines connected to photovoltaic power sources. However, unlike traditional synchronous generators, photovoltaic power sources provide fault currents with amplitudes typically less than 1.2 to 2 times the rated current, and their phase angles are controlled and capacitive. This often results in the differential current being insufficient to trigger the current differential protection even during internal faults. This paper analyzes the issues with applying traditional current differential protection to photovoltaic power sources connected lines and deduces the threshold for the ratio restraint coefficient. An adaptive protection strategy is proposed, where the restraint coefficient is adjusted based on the amplitude ratios and phase angle differences of the fault currents. This ensures correct operation, particularly in cases of high photovoltaic power sources penetration. The strategy is tested through simulations conducted in Power Systems Computer Aided Design (PSCAD), showing improved sensitivity compared to traditional methods.

1 January 2025 in IET Electric Power Applications
Verified
Journal Article
Open access
SSShi Su
Shi Su
YLYuan Li
Yuan Li
XHXuehao He
Xuehao He
QXQingyang Xie
Qingyang Xie
JSJiali Su
Jiali Su
CWChangqi Wang
Changqi Wang
Single‐phase grounding faults (SPGFs), especially high‐resistance faults, significantly weaken the electrical characteristics of active distribution networks (ADNs), thereby posing considerable challenges for faulted line selection (FLS). To address these challenges under flexible grounding conditions, this paper proposes an FLS method based on the ratio of zero‐sequence current variations. By establishing the zero‐sequence equivalent circuit of SPGFs in flexible grounding ADNs, the variation patterns of zero‐sequence currents in both faulted and nonfaulted feeders are analysed before and after the parallel insertion of a small grounding resistor. Using a designated reference feeder, the proposed method evaluates the magnitude and phase characteristics of zero‐sequence current variation ratios of other feeders relative to the reference. These features are then used to construct a reliable line selection criterion. The effectiveness of the method is validated through fault simulations carried out in PSCAD/EMTDC. Simulation results confirm that the proposed approach achieves high selection accuracy and demonstrates strong robustness against transition resistance.

9 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
YLYuan Li
Yuan Li
SSShi Su
Shi Su
FHfaping hu
faping hu
XHXuehao He
Xuehao He
BLBotong Li
Botong Li
FCFahui Chen
Fahui Chen
As the demand for power supply stability and reliability in the active distribution network (ADN) increases, the primary and secondary integrated intelligent switch (PSIIS) has become the primary choice for smart grid transformation in many weak infrastructure areas. However, the number of PSIISs that can be configured is often limited. It is necessary to comprehensively utilize the measurement data and sectional capabilities of PSIISs through the optimal configuration method to find the optimal configuration scheme. Therefore, fault observability-related indexes (FORIs) are proposed based on the functional characteristics of PSIISs. These indexes include fault type observability, fault location observability, fault current distribution characteristics observability, transition resistance observability, and weak infrastructure area observability. An optimization configuration model of PSIISs considering the comprehensive fault observability (CFO) is constructed. The adaptive genetic algorithm (AGA) is selected as the model-solving method. Subsequently, an optimal configuration method of PSIISs considering CFO is proposed. Finally, an example analysis is conducted in MATLAB to verify the effectiveness and feasibility of the proposed method. This optimal configuration method aims to maximize the use of a limited number of PSIISs by considering CFO, and the AGA proves to be an effective tool in solving the optimal configuration scheme.