With the high penetration connection of inverter-interfaced distributed generators and the increasing application of large-capacity energy routers, fully weak-infeed distribution networks consisting entirely of power-electronized weak-infeed power sources are set to become one of the fundamental forms of future distribution networks. For fully weak-infeed distribution networks, multi-terminal current differential protection is considered an optional or even preferred line protection scheme. In this paper, a multi-terminal current differential protection setting method for fully weak-infeed distribution networks is proposed based on the restricted enumeration method. To address the impact of data synchronization errors and measurement errors of multi-terminal current on differential current, the problem of determining the maximum differential current superimposed with the multi-terminal current phasor errors is transformed into a high-dimensional non-convex optimization problem. The distribution law of the global optimal solution in the non-convex constraint space is deeply studied and analyzed, and a restricted enumeration method is proposed that can quickly solve the protection setting value, thereby solving the problem of multi-terminal current differential protection setting. The accuracy and rapidity of the proposed method are verified by comparing the calculation accuracy and time consumption of the restricted enumeration method and the exhaustive search. It is shown that the proposed multi-terminal differential protection setting method exhibits sufficient reliability and sensitivity in fully weak-infeed distribution networks, as verified through simulation analysis using a fully weak-infeed distribution network model built in PSCAD/EMTDC.
Reliable fault line selection technology is crucial for preventing fault range expansion and ensuring the reliable operation of distribution networks. Modern distribution systems with neutral earthing via arc extinguishing coil face challenges during single-phase ground faults due to indistinct fault characteristics and system sequence networks influenced by the grounding methods on the distributed generation side. These factors increase the difficulty of fault line selection. By analyzing the differences between the zero-sequence currents of feeder lines and neutral lines in active distribution networks with neutral earthing via arc extinguishing coil, a method for single-phase ground fault line selection has been proposed in this paper. This method involves switching from a neutral point ungrounded mode to a low-resistance neutral grounding mode using distributed generation grid-connected transformers under permanent fault conditions. Criteria based on the differences in zero-sequence current ratios before and after the grounding mode switch are established. Simulation validation using the Power Systems Computer Aided Design (PSCAD) platform has been conducted. The proposed method demonstrates strong tolerance to transition resistance, simple extraction of fault characteristic signals, and accurate fault line selection results.
To address the impact of distributed generation (DG) access on the traditional protection configuration methods of distribution networks (DNs) and to facilitate the swift and effective protection of lines by protection devices under fault conditions, an adaptive current protection method for three‐phase short‐circuit faults in active distribution networks (ADNs), based on local information, is proposed. Initially, the applicability issues of traditional protection are examined, and the limitations of the existing protection scheme in ADNs are highlighted. Subsequently, the fault characteristics of ADNs are analysed, taking into account the output characteristics of DGs under short‐circuit faults, which form the foundation for the proposed protection method. Following this, an adaptive current protection method based on local information is introduced, utilizing a dual criterion of phase and magnitude to adjust line protection, with a specific implementation strategy for the protection scheme provided. Finally, the proposed protection scheme is validated using PSCAD/EMTDC simulation software, with results demonstrating that the scheme enables rapid and efficient protection action under fault conditions across the entire line.
As the demand for power supply stability and reliability in the active distribution network (ADN) increases, the primary and secondary integrated intelligent switch (PSIIS) has become the primary choice for smart grid transformation in many weak infrastructure areas. However, the number of PSIISs that can be configured is often limited. It is necessary to comprehensively utilize the measurement data and sectional capabilities of PSIISs through the optimal configuration method to find the optimal configuration scheme. Therefore, fault observability-related indexes (FORIs) are proposed based on the functional characteristics of PSIISs. These indexes include fault type observability, fault location observability, fault current distribution characteristics observability, transition resistance observability, and weak infrastructure area observability. An optimization configuration model of PSIISs considering the comprehensive fault observability (CFO) is constructed. The adaptive genetic algorithm (AGA) is selected as the model-solving method. Subsequently, an optimal configuration method of PSIISs considering CFO is proposed. Finally, an example analysis is conducted in MATLAB to verify the effectiveness and feasibility of the proposed method. This optimal configuration method aims to maximize the use of a limited number of PSIISs by considering CFO, and the AGA proves to be an effective tool in solving the optimal configuration scheme.