Mohammad Alamri

Dr. Mohammad Alamri

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2024 in Medical Science Monitor
Verified
Journal Article
Open access
SJSaurabh Jain
Saurabh Jain
Mohammed SayedMohammed Sayed
Mohammed Sayed
RKReem Abdullah A. Khawaji
Reem Abdullah A. Khawaji
GHGhada Ali J. Hakami
Ghada Ali J. Hakami
ESEman Hassan M. Solan
Eman Hassan M. Solan
KMKhurshid Mattoo
Khurshid Mattoo
Accuracy of 3 Intraoral Scanners in Recording Impressions for Full Arch Dental Implant-Supported Prosthesis: An In Vitro Study - Article abstract #946624

20 November 2023 in Medical Science Monitor Basic Research
Verified
Journal Article
Open access
Mohammed SayedMohammed Sayed
Mohammed Sayed
DLDr.Honey Lunkad
Dr.Honey Lunkad
KMKhurshid Mattoo
Khurshid Mattoo
HJHossam F Jokhadar
Hossam F Jokhadar
SASaad AlResayes
Saad AlResayes
AMAmal M. Masmali
Amal M. Masmali
Background: Replicating the 3-dimensional (3D) color of natural teeth in artificial substitutes is challenging. Fixed dental prosthodontics require aesthetic, color-stable provisional restorations. Recent milling and 3D printing digital manufacturing techniques offer improved outcomes. This study assesses color stability in various digital manufacturing methods, tapers, and aging effects on anterior provisional resin restorations. Material/Methods: Two all-ceramic tooth preparations on typodont teeth with 10 degrees and 20 degrees tapers were converted into experimental dies. Forty temporary crowns were manufactured using 3D printing and computer-aided design/computeraided manufacturing (milling). Within these 2 groups, 10 crowns were cemented using a regular and clear provisional cement. All samples were thermocycled to simulate clinical use of 6 months. Color difference formula (CIEDE2000) indicated changes between before and after cementation (AE00[I]) and between after cementation and after thermocycling (AE00[II]). The color change was considered significant in terms of clinically perceptible (AE00 <= 0.62) and acceptable (AE00 <= 2.62) changes. One-way ANOVA (P value of less than 0.05) calculated overall differences, which were established using a Fisher post hoc test. Results: Crowns cemented with clear cement showed fewer color changes irrespective of the manufacturing technique or taper. Notably, only the 10 degrees 3D-printed crown with clear cement had an imperceptible color change at the pre-/post-cementation phase. Meanwhile, the 10 degrees and 20 degrees milled crowns with regular cement exhibited unacceptable color changes after thermocycling. Conclusions: For long-term temporization in the aesthetic zone, properly optimized 3D-printed provisional restorations cemented with clear cement had better color stability.

30 December 2023 in Medical Science Monitor
Verified
Journal Article
Open access
Mohammed SayedMohammed Sayed
Mohammed Sayed
SJSaurabh Jain
Saurabh Jain
AAAbrar A. Ageeli
Abrar A. Ageeli
AAAlhanouf K. Alnajdi
Alhanouf K. Alnajdi
AZAsma Ahmed Zain
Asma Ahmed Zain
KMKhurshid Mattoo
Khurshid Mattoo
Background: Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. Material/Methods: Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (Delta E) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. Results: NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (Delta E=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. Conclusions: ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.

28 December 2024 in Polymers
Verified
Journal Article
Open access
PDF file
Firas Khalid AlqarawiFiras Khalid Alqarawi
Firas Khalid Alqarawi
BABandar AL-Makramani
Bandar AL-Makramani
PGPRAVEEN GANGADHARAPPA
PRAVEEN GANGADHARAPPA
KMKhurshid Mattoo
Khurshid Mattoo
MHMaryam Hadi
Maryam Hadi
Mohammed SayedMohammed Sayed
Mohammed Sayed
Interocclusal records (IORs) created with bite registration materials (BRMs) accurately reflect the opposing teeth’s physiological and anatomical associations in digital and traditional dentistry. This study assessed the linear dimensional accuracy of vinyl polysiloxane-based scannable and transparent BRMs over obligatory clinical time intervals (1, 24, 72, and 168 h/s). A total of 3 scannable [Flexitime Bite, Occlufast CAD, Virtual CADBite] and 3 transparent [Maxill Bite, Charmflex Bite, Defend ClearBite] VPS-based BRMs were divided into 28 subgroups by time interval: 1, 24, 72, and 168 h/s. Stereomicroscope measurements of 420 standardised disk-shaped specimens with three distinct linear distances between crossing vertical and horizontal lines were taken. Comparisons with the conventional BRM determined the scannable and transparent BRMs’ accuracy, while comparisons with die dimensions yielded linear dimensional changes. Statistical analysis used median rank scores, interquartile range, and median. Using a one-way ANOVA rank and Dunn test, differences were assessed between and within groups at a probability ‘p’ value of 0.05 (p ≤ 0.05). Mean linear dimensions for CAD and transparent IOR materials were [−0.06 (−0.24%) to −0.15 (−0.6%)] and [−0.06 (0.24%) to −0.10 (0.40%)] millimetres, respectively. Virtual CADBite and Maxill Bite had the lowest linear disagreement after 1 h, but both showed significant variations at 7 days. Other commercial brands maintained their clinically acceptable linear accuracy (0.11). Flexitime Bite (CAD) was the sole material with a linear accuracy above the clinical threshold. IOR shrinkage reduced the linear dimensions in all materials. Until 7 days, all IOR materials except Flexitime bite (CAD) were clinically correct. Virtual CADBite and Maxill bite changed significantly during 1 h and 7 days.

9 December 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
Saleh Ali AlqahtaniSaleh Ali Alqahtani
Saleh Ali Alqahtani
MAMohammad Alamri
Mohammad Alamri
GAGhadeer Alwadai
Ghadeer Alwadai
NANaif Abogazalah
Naif Abogazalah
VMVinod Babu Mathew
Vinod Babu Mathew
BJBetsy Joseph
Betsy Joseph
Preserving dental pulp vitality is a key goal in minimally invasive dentistry. Conventional materials such as calcium hydroxide and mineral trioxide aggregate (MTA) are effective but limited in bioactivity and mechanical strength. This systematic review evaluated the biological efficacy of chitosan-based nanoparticles and biomaterials for pulp capping and regeneration. Following PRISMA 2020 guidelines, electronic searches were conducted across five databases up to April 2025. Controlled in vitro and animal studies using chitosan-based nanoparticles, hydrogels, or composite scaffolds were included. Risk of bias was assessed using SYRCLE (animal) and ToxRTool (in vitro), and certainty of evidence was rated via the GRADE-Preclinical framework. Due to methodological heterogeneity, data were synthesized using direction-of-effect coding and visualized through Albatross and heatmap plots. Sixteen studies met the criteria, consistently demonstrating enhanced cell viability, mineralization, and upregulation of odontogenic and angiogenic markers (BMP-2, TGF-β1, VEGF, DSPP) compared with MTA or calcium hydroxide. Animal models confirmed improved angiogenesis, reparative dentin formation, and pulp vitality preservation. Despite uniformly positive biological outcomes, the overall certainty was rated Low to Very Low owing to small samples and unclear randomization. Chitosan-based biomaterials show promising regenerative potential, warranting well-designed preclinical and clinical studies for translational validation.

19 September 2023 in Medical Science Monitor
Verified
Journal Article
Open access
BABandar AL-Makramani
Bandar AL-Makramani
Mohammed SayedMohammed Sayed
Mohammed Sayed
FAFuad A. Al-Sanabani
Fuad A. Al-Sanabani
KMKhurshid Mattoo
Khurshid Mattoo
NANasser M. Alqahtani
Nasser M. Alqahtani
RERami Eshaq
Rami Eshaq
Background: The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast.Material/Methods: Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (con-trol group). Opposing mandibular casts obtained from three different impression materials [Hydrogum Alginate (Conventional), Hydrocolor 5 (Extended-Pour Alginate), FreeAlgin (Alginate Alternative)] and 3-dimensional print constituted test groups [Gp AL(C)], [Gp AL(E)], [Gp AL(F)] and [Gp 3D-C], respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P pound 0.05 using the single-sample t test, ANOVA, and Tukey test.Results: The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the er-ror of means among the 4 tested groups [Gp AL(C), Gp AL(E), Gp AL(F), and Gp 3D-C] were detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences.Conclusions: The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.