杨枝 薛

杨枝 薛

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BSBowen Sun
Bowen Sun
DMDanyue Ma
Danyue Ma
XFXiujie Fang
Xiujie Fang
杨薛杨枝 薛
杨枝 薛
Jixi LuJixi Lu
Jixi Lu
YZYueyang Zhai
Yueyang Zhai
Most magnetic shielding rooms (MSRs) are made of highly permeable permalloy. The limitation of such MSR is its intrinsic magnetic noise, which exceeds the sensitivity of magnetic sensors, impeding the further applications of ultrasensitive magnetic sensors, such as the magnetometers operated in the spin-exchange relaxation free (SERF) regime. In this article, a cubic ferrite magnetic shield with a low magnetic noise and magnetic field is proposed. The demagnetization model and magnetic noise calculation models are given. After optimizing several different coil structures and degaussing parameters, the magnetic field and the magnetic noises inside the cubic ferrite shield were measured. Within a distance of ±10 mm near the center, the residual magnetic field is below 0.5, 1.72, and 1.57 nT at the x-, y- and z- directions. The magnetic noise measurements at the center of the cubic ferrite magnetic shield reveal an averaged magnetic noise of 2.62 fT/Hz−1/2 from 20 to 100 Hz. Compared with the noise spectrum of permalloy shield, the noise level is reduced more than 133%. The results of this scaled-down cubic ferrite magnetic shield can be applied in larger sized shielding rooms. By assembling multiple ferrite panels together, it is possible to create a larger shielding space with a low magnetic field and low magnetic noise.

5 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PSPeipei Shen
Peipei Shen
Shuyan ZhangShuyan Zhang
Shuyan Zhang
DMDanyue Ma
Danyue Ma
BXBozheng Xing
Bozheng Xing
HCHua Chen
Hua Chen
BHBangcheng Han
Bangcheng Han
High-shielding coefficient and low-noise magnetic shielding systems play an important role in the field of ultrahigh-sensitive magnetic field sensors and biomagnetism measurements. Currently, the magnetic shielding systems often suffer from high intrinsic magnetic noise generated by μ-metal. In this study, cobalt-based metallic glass with high permeability and excellent soft magnetic properties was employed to design magnetic shielding cylinders with an inner diameter of 240 mm. Using the Finite Element Method simulation, the shielding coefficient S of the single-layer cobalt-based metallic glass (20 μm thickness) magnetic shielding cylinder was 11.27 for the geomagnetic field. The magnetic noise characteristics of cobalt-based metallic glass magnetic shielding cylinder were analyzed based on complex permeability and resistivity in the obtained frequency band. In addition, we also experimentally studied the effectiveness of cobalt-based metallic glass magnetic shielding cylinder with different layers, when used as the innermost magnetic shielding layer, in suppressing the magnetic noise generated by μ-metal. The experimental results show that the minimum magnetic noise of the ten-layer cobalt-based metallic glass magnetic shielding cylinder is only 1.3 fT/Hz1/2, which indicates that cobalt-based metallic glass as an innermost magnetic shielding layer material can effectively reduce the magnetic noise generated by μ-metal and verifies the superiority of cobalt-based metallic glass in achieving low noise. Moreover, the ultra-thin structure and low cost of the cobalt-based metallic glass magnetic shielding cylinder offer significant advantages for other applications requiring the measurement of extremely weak magnetic fields. This study confirms the potential of cobalt-based metallic glass in improving the performance of magnetic shielding systems.

16 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
PSPeipei Shen
Peipei Shen
YGYanan Gao
Yanan Gao
Shuyan ZhangShuyan Zhang
Shuyan Zhang
HCHua Chen
Hua Chen
PWPengfei Wang
Pengfei Wang
Jixi LuJixi Lu
Jixi Lu
Cobalt-based metallic glasses have sparked intensive attention because of their extraordinary properties. In this work, a series of Co66Fe4Mo2-xTaxSi16B12 (x = 0, 0.5, 1.0, 1.5, 2.0) metallic glass ribbons were systematically designed to investigate the influence of the minor Ta substitution for Mo on the thermal behavior and magnetic performance. The results reveal that the width of the supercooled liquid region initially increases with Ta content, reaching 98 K at x = 1.0, and subsequently decreases with further Ta addition. It indicates that the Co66Fe4Mo1.0Ta1.0Si16B12 alloy has the optimal glass-forming ability. Moreover, the crystallization onset temperature and crystallization peak temperature of all as-quenched ribbons were improved with the Ta content x increasing to 2.0, which is due to the higher melting temperature of the element Ta (3290 K). In addition, these ribbons exhibit outstanding soft magnetic properties, including ultralow coercivity (Hc < 1.1 A/m) and moderate saturation magnetization, which indicates that these ribbons are suitable for magnetic shielding. These results offer valuable insights into the design of soft magnetic metallic glass.

9 November 2025 in Measurement
Verified
Journal Article
Closed access
杨薛杨枝 薛
杨枝 薛
XFXiujie Fang
Xiujie Fang
YGYanan Gao
Yanan Gao
Jixi LuJixi Lu
Jixi Lu
BSBowen Sun
Bowen Sun
DMDanyue Ma
Danyue Ma