Roberto Dinapoli

Dr. Roberto Dinapoli

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMChristopher Milne
Christopher Milne
TSThomas Schietinger
Thomas Schietinger
MAMasamitsu Aiba
Masamitsu Aiba
AAArturo Alarcon
Arturo Alarcon
JAJürgen Alex
Jürgen Alex
HBHans-Heinrich Braun
Hans-Heinrich Braun
The SwissFEL X-ray Free Electron Laser (XFEL) facility started construction at the Paul Scherrer Institute (Villigen, Switzerland) in 2013 and will be ready to accept its first users in 2018 on the Aramis hard X-ray branch. In the following sections we will summarize the various aspects of the project, including the design of the soft and hard X-ray branches of the accelerator, the results of SwissFEL performance simulations, details of the photon beamlines and experimental stations, and our first commissioning results.

1 May 2014 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
RDRoberto Dinapoli
Roberto Dinapoli
ABAnna Bergamaschi
Anna Bergamaschi
SCS Cartier
S Cartier
DGDominic Greiffenberg
Dominic Greiffenberg
IJI Johnson
I Johnson
Gemma TintiGemma Tinti
Gemma Tinti

23 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DGDominic Greiffenberg
Dominic Greiffenberg
MAMarie Andrä
Marie Andrä
RBRebecca Barten
Rebecca Barten
ABAnna Bergamaschi
Anna Bergamaschi
MBMartin Brückner
Martin Brückner
JZJiaguo Zhang
Jiaguo Zhang
Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e− ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called “crater effect” which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the “crater effect” is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the “crater effect” on the detector operation.

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MAMaria del mar Carulla Areste
Maria del mar Carulla Areste
RBRebecca Barten
Rebecca Barten
FBFilippo Baruffaldi
Filippo Baruffaldi
ABAnna Bergamaschi
Anna Bergamaschi
GBGiacomo Borghi
Giacomo Borghi
JZJiaguo Zhang
Jiaguo Zhang
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.

11 December 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
XXX. Xie
X. Xie
ABA. Bergamaschi
A. Bergamaschi
MBM. Brückner
M. Brückner
MCM. Carulla
M. Carulla
RDRoberto Dinapoli
Roberto Dinapoli
JZJ. Zhang
J. Zhang

8 March 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Gianluca TraversiGianluca Traversi
Gianluca Traversi
RDRoberto Dinapoli
Roberto Dinapoli
MMMassimo Manghisoni
Massimo Manghisoni
AMAldo Mozzanica
Aldo Mozzanica
Elisa RiceputiElisa Riceputi
Elisa Riceputi