Shuchao WU

Prof. Dr. Shuchao WU

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YBYanzheng Bai
Yanzheng Bai
ZLZhuxi Li
Zhuxi Li
MHMing Hu
Ming Hu
LLLi Liu
Li Liu
SQShaobo Qu
Shaobo Qu
ZZZebing Zhou
Zebing Zhou
High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented.

6 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JYJianbo Yu
Jianbo Yu
CWChengrui Wang
Chengrui Wang
YWYing Wang
Ying Wang
YBYanzheng Bai
Yanzheng Bai
MHMing Hu
Ming Hu
ZZZebing Zhou
Zebing Zhou
Ultra-sensitive inertial sensors are one of the key components in satellite Earth’s gravity field recovery missions and space gravitational wave detection missions. Low-noise capacitive position transducers are crucial to these missions to achieve the scientific goal. However, in actual engineering applications, the sensor head and electronics unit usually place separately in the satellite platform where a connecting cable is needed. In this paper, we focus on the stray-capacitance influences of coaxial cables which are used to connect the mechanical core and the electronics. Specially, for the capacitive transducer with a differential transformer bridge structure usually used in high-precision space inertial sensors, a connecting method of a coaxial cable between the transformer’s secondary winding and front-end circuit’s preamplifier is proposed to transmit the AC modulated analog voltage signal. The measurement and noise models including the stray-capacitance of the coaxial cable under this configuration is analyzed. A prototype system is set up to investigate the influences of the cables experimentally. Three different types and lengths of coaxial cables are chosen in our experiments to compare their performances. The analysis shows that the stray-capacitance will alter the circuit’s resonant frequency which could be adjusted by additional tuning capacitance, then under the optimal resonant condition, the output voltage noises of the preamplifier are measured and the sensitivity coefficients are also calibrated. Meanwhile, the stray-capacitance of the cables is estimated. Finally, the experimental results show that the noise level of this circuit with the selected cables could all achieve 1–2 × 10−7 pF/Hz1/2 at 0.1 Hz.

1 June 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SHShuang Hu
Shuang Hu
SPShixun Pei
Shixun Pei
MHMing Hu
Ming Hu
YBYanzheng Bai
Yanzheng Bai
HLHongyin Li
Hongyin Li
ZZZebing Zhou
Zebing Zhou
A high precision electrostatic accelerometer has widely been employed to measure gravity gradients and detect gravitational waves in space. The high-voltage levitation method is one of the solutions for testing electrostatic accelerometers on the ground, which aims at simultaneously detecting all six-degree-of-freedom movements of the electrostatic accelerometers engineering and flight prototypes. However, the noise performance in the high-voltage levitation test is mainly limited by seismic noise. The combined test of the accelerometer and vibration isolation platform is adopted to improve the detection precision of the high-voltage levitation method. In this paper, a high precision electrostatic accelerometer prototype is developed after designed appropriate mechanical parameters with a test mass weighing 300 g and with an estimated resolution of 2 × 10−12 m/s2/Hz1/2 from 0.01 to 0.4 Hz. Such a prototype is tested by the high-voltage levitation method, its measurement noise on the ground is mainly limited by the seismic noise, which is about 5 × 10−7 m/s2/Hz1/2 around 0.2 Hz and about 4 × 10−8 m/s2/Hz1/2 around 0.1 Hz. A vibration isolation pendulum bench based on the translation–tilt compensation principle is adopted for accelerometer prototype combined tests to suppress the seismic noise, which has a large bench area and the ability to adjust the tilt angle precisely. The measured accelerometer noise of the combined test with the translation–tilt compensation pendulum has reached 3 × 10−9 m/s2/Hz1/2 around 0.2 Hz, and it is about two orders of magnitude lower than the measurement noise on the ground. The combined test method provides technical guidance for further improving the noise level of ground test in the future.

1 August 1997 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SFShuhua Fan
Shuhua Fan
SWShuchao WU
Shuchao WU
JLJun Luo
Jun Luo
This article presents the construction and performance of a new type of temperature sensor, which can resolve temperature changes of the order of 10−4 °C in the range of 0.1 °C. Measured with the new temperature sensor, the daily change of temperature in our underground laboratory is less than 0.0034 °C.

10 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BMBin Mei
Bin Mei
CMCheng Ma
Cheng Ma
YBYanzheng Bai
Yanzheng Bai
MHMing Hu
Ming Hu
LLLi Liu
Li Liu
ZZZebing Zhou
Zebing Zhou
The high-precision electrostatic accelerometer is the key payload for satellite gravity measurement, so ground testing and verification of its performance is critical. Our group has previously developed a series of test benches that can be used to provide a ground test environment of 10-9 m/s2/Hz1/2 level. In this paper, a novel performance evaluation device for high-precision accelerometers based on an active vibration isolation system is proposed. An electrostatic accelerometer with a theoretical noise level of 10-10 m/s2/Hz1/2 is used as the motion sensor, and the active feedback control is carried out in combination with the four-wire pendulum. The system noise model is further analyzed in detail. The experimental results show that the vibration transmissibility of this system using acceleration sensing is better than that using velocity sensing, which verifies the effectiveness of the proposed method. The total residual noise level on the test bench measured by the seismometer is verified to be about 1×10-9 m/s2/Hz1/2 from 0.5 Hz to 0.8 Hz, while the performance of the electrostatic accelerometer itself is evaluated to be 7×10-10 m/s2/Hz1/2 from 0.3 Hz to 0.6 Hz.

13 January 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
YJYiyan Jiang
Yiyan Jiang
JLJinfeng Lu
Jinfeng Lu
COChaoli Ouyang
Chaoli Ouyang
HZHongtao Zhou
Hongtao Zhou
MHMing Hu
Ming Hu
ZZZebing Zhou
Zebing Zhou
To realize the free falling test mass (TM) in gravitational wave detection in space, an alternative current (AC) electrostatic control strategy is proposed and developed. It is significant to test and verify the AC control actuation scheme on the ground. In this paper, a two-stage torsion pendulum is used to test the performance of the AC control actuator of inertial sensor for Tianqin project. First, the pendulum facility combined with a TM, a capacitive position sensor and an AC control actuator is constructed. Experimental results show that the sensitivities of the pendulum achieve 4.2 × 10 −11 N Hz −1/2 at 6 mHz and 1.6 × 10 −13 Nm Hz −1/2 at 15 mHz, respectively, and the pendulum provides a chance to realize the performance test of two degree-of-freedom sensitivities of the actuator, experimental verification of AC control strategy and so on, which is first reported to test performance of the AC control actuator of a space inertial sensor on the ground.